Base de connaissances

How to decode raw data on ECC memory errors for the PowerEdge C1100, C2100, C6100, C6105, C6145, C6220 and C8220.



Article Summary: This article describes how to decode raw data on ECC memory errors in the System Event Log on the PowerEdge C1100, C2100, C6100, C6105, and C6145.


Issue:

For PowerEdge C-series servers use the attached excel tool to decode the SEL RAW data to figure out which DIMM slot is/was having problem.

Note: This tool is only for decoding memory ECC errors.


Solution:

How to collect the RAW SEL data:

  1. Use IPMI tool to get SEL RAW event data with the following parameter
    #ipmitool sel list -v (Find out the memory related RAW event data from output.)
  2. Download the excel file and open it.
  3. Select the platform you’re working on from the drop-down list and fill in the RAW event data which you got in step#1 in Cell#B2 and press Enter.
  4. It will tell you which DIMM slot has a problem.
Note: Use the impitool sel list -v command to get Event Raw Data.

Example one of SEL record:

SEL Record ID : 0021
Record Type : 02
Timestamp : 02/08/2012 12:40:58
Generator ID : 0021
EvM Revision : 04
Sensor Type : Memory
Sensor Number : 60
Event Type : Sensor-specific Discrete
Event Direction : Assertion Event
Event Data : a1ff14 (This is the Event Raw data you need to fill the 6 bytes into cell#B2.)
Description : Uncorrectable ECC




Identificateur de l'article : SLN156243

Date de la dernière modification : 03/07/2016 09:59 AM


Évaluer cet article

Précis
Utile
Facile à comprendre
Cet article était-il utile?
Oui Non
Envoyez-nous votre évaluation
Les commentaires ne peuvent pas contenir ces caractères spéciaux : <>()\
Désolés, notre système d’évaluation n’est pas accessible actuellement. Veuillez réessayer plus tard.

Nous vous remercions pour vos commentaires.