PowerVault Disk Backup

Open
Back to Previous Page

Removable disk backup and continuous data protection

PowerVault DL4000 Storage
PowerVault RD1000 External Tape Drive

PowerVault RD1000

Customers seeking a rugged, removable disk backup for servers or desktops with a simple USB port connection.

Select

PowerVault TL1000

Automate backups and save time with an affordable, high-density tape autoloader featuring a compact 1U design and remote management.

View Details

GREAT FOR

Customers seeking a rugged, removable disk backup for servers or desktops with a simple USB port connection.

Cost-effective disaster recovery, consolidating multiple or remote application servers, and providing unattended, automated backup.

Media

RD1000 Media Technical Specifications:

 

2TB Media

Capacity (Native): 2TB
Capacity (Compressed): 4TB
Average sustained transfer rate: Internal SATA 30 MBps / External USB3.0 80 MBps
Burst transfer rate: Internal SATA 1.5 Gbps / External USB3.0 5 Gbps
Average access time (msec): 15
Function: Removable disk drive
Logical block size: 512 bytes
Support file system: ext2, ext3, FAT32 and NTFS (Default)
Unrecoverable error rate: 1 error per 10^14 bits read
MTBF Internal USB Device: 550,000 hours

1TB Media

Capacity (Native): 1TB
Capacity (Compressed): 2TB
Average sustained transfer rate: Internal SATA 30 MB/s / External USB 25 MB/s
Burst transfer rate: Internal SATA 1.5 Gbps / External USB 480 Mbps
Average access time (msec): 15
Function: Removable disk drive
Logical block size: 512 bytes
Support file system: ext2, ext3, FAT32 and NTFS (Default)
Unrecoverable error rate: 1 error per 10^14 bits read
MTBF Internal USB Device: 550,000 hours

500GB Media

Capacity (Native): 500GB
Capacity (Compressed): 1TB
Average sustained transfer rate: Internal SATA 30 MB/s / External USB 25 MB/s
Burst transfer rate: Internal SATA 1.5 GB/s / External USB 480 MB/s
Average access time (msec): 15
Function: Removable disk drive
Logical block size: 512 bytes
Support file system: ext2, ext3, FAT32 and NTFS (Default)
Unrecoverable error rate: 1 error per 10^14 bits read
MTBF Internal USB Device: 550,000 hours

320GB Media

Capacity (Native): 320GB
Capacity (Compressed): 640GB
Average sustained transfer rate: Internal SATA 30 MB/s / External USB 25 MB/s
Burst transfer rate: Internal SATA 1.5 GB/s / External USB 480 MB/s
Average access time (msec): 15
Function: Removable disk drive
Logical block size: 512 bytes
Support file system: ext2, ext3, FAT32 and NTFS (Default)
Unrecoverable error rate: 1 error per 10^14 bits read
MTBF Internal USB Device: 550,000 hours

Performance

Characteristic: Storage capacity varies by individual cartridge capacity
Average sustained transfer rate: USB 25 MB/s
Burst transfer rate: 480 MB/s
Typical transfer rate: 80MB/s
Maximum burst transfer rate: 230 MB/s
Max theoretical transfer rate: 375 MB/s
Average access time (msec): 15
Function: Removable disk drive
Command set:
Packet command feature set, per ATA/ATAPI-7
SCSI primary commands (SPC-2)
SCSI block commands (SBC-2)
Logical block size: 512 bytes
Supported file system: ext2, ext3, FAT32 and NTFS (Default)

Capacity and transfer rate will vary depending on the RD1000 cartridge type used.

Reliability

Unrecoverable error rate: 1 error per 10^14 bits read
MTBF Internal USB Device: 550,000 hours
Cartridge Drop Test: RD1000 cartridges have been qualified to withstand a drop of 1M to a tile over concrete floor. In most cases the RD1000 cartridges can withstand drops of up to 1.5M.

Server Compatibility

Dell and x86 IBM and HP Servers

Chassis

RD1000 Internal Devices

Form Factor: 5.25 inch internal
Height: 41.4 mm (1.63 inch)
Width: 146.0 mm (5.75 inch)
Depth: 171.9 mm (6.77 inch) including bezel
Weight: 635 g (1.40 lbs)

Form Factor: 3.5 inch internal
Height: 41.4 mm (1.63 inch)
Width: 101.6 mm (4.00 inch)
Depth: 159.4 mm (6.28 inch) including bezel
Weight: 408 g (0.90 lbs)

PowerVault 114X

Form Factor: 2U Rack Mount
Height: 86.9 mm (3.42 inch)
Width: 482.5 mm (19.00 inch)
Depth: 480.7 mm (18.93 inch) including bezel
Weight: 8.3 Kg (18.4 lbs)

Interface Type: USB 3.0

RD1000 Media

Form Factor: Removable Cartridge
Height: 23.68 mm (0.93 inch)
Width: 86.6 mm (3.4 inch)
Depth: 119.18 mm (4.69 inch)
Weight: 173 g (0.38 lbs)
1U form factor
Height: 44 mm (1.73 in)
Width (chassis/bezel): 445 mm (17.52 in)/483 mm (19.02 in)
Length: 850 mm (33.46 in)
Weight: 13 kg (28.66 lb)
Orientation: Horizontal only

Power

Internal RD1000 Devices

Voltage Tolerance: +5VDC ±5%, +12VDC ±10%
Amperage Rating: 1.8A, 0.005A

PowerVault 114X

Voltage Tolerance: 100-240VAC
Amperage Rating: 1.9-0.8A

Environmental

Temperature

Operational: 10 to 40°C
Non-Operational: -40 to 65°C

Thermal Gradient

Operational: 10°C/hour
Non-Operational: 20°C/hour

Relative Humidity

Operational: 20 to 80%, non-condensing
Non-Operational: 10 to 90%, non-condensing

Maximum Wet Bulb Temperature

Operational: 29°C, non-condensing
Non-Operational: 38°C, non-condensing

Altitude

Operational: -50 ft to 10,000 ft
Non-Operational: -50 ft to 35,000 ft

Vibration

Operational: sine vib 0.25G peak, 3-200 Hz
Non-Operational: random vib 1.54G RMS

Shock

Operational: half sine 31G @ 2.6ms
Non-Operational: half sine 71G @ 2 ms

Regulatory

Software

There are two user interfaces:

- Operator Control Panel. Located on the front of the PV TL1000 tape library, the user can use the LCD panel to check system status, run diagnostics, view system logs, check and set configurations, verify drive operations, run an inventory and manage the system.

- Remote Web Management. The web-based administration can be accessed via a 10/100 BASE-T connection through any standard web browser. The user can check system status, view system logs, check and set configurations, verify drive operations, run an inventory and manage the system. In addition, the user can upgrade the drive and library firmware via the Remote Management Unit (RMU).

Tape Backup Technology

LTO-4, LTO-5, LTO-6

Library Configurations

Rack mount standard

Barcode Reader

Standard

Connectivity

Network interface
ADI T-10
Ethernet RJ-45
IPv6 Phase 1 & 2 Ready and DoD APL

Environmental Operating Conditions

Temperature
50 to 95 degrees F, 10 to 35 degrees C
Humidity (operating)
20% to 80% RH (non-condensing)
close
 
 