|

Chassis Switches

Open
Back to Previous Page

High-performance, resilient architectures and versatile platforms for next-generation data centers and enterprise campus networks.

Dell Networking C-Series chassis-based switches

Dell Networking C7000 chassis-based switches

Build a resilient network infrastructure that offers flexibility, expansion and broad customization with Dell Networking C-Series chassis-based switches.

View Details

Dell Networking C9010 Modular Chassis Switch

The Dell Networking C9010 is a centrally managed, highly scalable modular switch for enterprise campus and mid-market data center networks.

View Details

GREAT FOR

Building a resilient network infrastructure that offers flexibility, expansion and broad customization across your enterprise.

The Dell Networking C9010 is a highly scalable modular switch, providing centralized management for enterprise campus and mid-market data center networks.

Performance

MAC addresses:256K
IPv4/IPv6 routes: 12K/6K
Switching fabric capacity:
C7004: 768 Gbps (476 Mpps)
C7008: 1.536 Tbps (952 Mpps)
Link aggregation: 8 links per group, 128 groups per chassis
Queues per port: 4 queues
VLANs: 1024 VLANs with 4096 tag value support
Line-rate Layer 2 switching: all protocols, including IPv4 and IPv6
Line-rate Layer 3 routing: IPv4 and IPv6
LAG load balancing: based on Layer 2, IPv4 or IPv6 headers
Switching latency: <5 µs for 64 byte frames
MAC addresses: 160K
IPv4 routes: 128K in scaled mode (16K in default mode)
IPv6 routes: 32K (shared CAM space with IPv4)
RPM switch fabric capacity: 2.56Tbps (full-duplex), 1.28Tbps (half-duplex)
RPM throughput: 1,462 Mpps
Line Card switch fabric capacity: 1.44Tbps (fullduplex), 720Gbps (half-duplex)
Line Card throughput: 714 Mpps
Link aggregation: 16 links per group, 128 groups per stack
Queues per port: 8 queues
Layer 2 VLANs: 4K
MSTP : 64 instances
VRF-lite: 32 instances (64 in future release)
Line-rate Layer 2 switching: all protocols, including IPv4 and IPv6
Line-rate Layer 3 routing: IPv4 and IPv6
IPv4 host table size 32K
IPv6 host table size 16K
IPv4 Multicast table size 4K
LAG load balancing: based on Layer 2, IPv4 or IPv6 headers

Availability

1+1 redundant Switch Fabric & Route Processor Modules (RPM)
1+1 redundant system AC Power Supply Modules
Supports over 300 PoE+ ports at 30 W Redundant power supplies/PSUs (Note: all power supplies must be of the same type for switch operation) 

C7004: 2+1 redundant system AC PSU (minimum) 2 PSU (redundant) or 1 PSU minimum for 100/120 or 200/240 VAC, using either 1600W or 1200W PSU Up to 5+1 redundant PSUs supported PoE+ operation requires 1600W PSU; PoE operation uses 1600W or 1200W PSU Online insertion and removal of all components Environmental self-monitoring

C7008: 3 PSU (redundant) or 2 PSU minimum for 100/120 VAC, using either 1600W or 1200W PSU3 PSU (redundant) or 2 PSU minimum for 200/240 VAC, using 1200W PSU2 PSU (redundant) or 1 PSU minimum for 200/240 VAC, using 1600W PSU Up to 7+1 redundant PSUs supported PoE+ operation requires 1600W PSU; PoE operation uses 1600W or 1200W PSU

General Internet Protocols
768 UDP
793 TCP
854 Telnet
959 FTP
1321 MD5
1350 TFTP
2474 Differentiated Services
3164 Syslog
draft-ietf-bfd-base-03 BFD  

General IPv4 Protocols
791 IPv4
792 ICMP
826 ARP
1027 Proxy ARP
1035 DNS (client)
1042 Ethernet Transmission
1191 Path MTU Discovery
1305 NTPv3
1519 CIDR
1542 BOOTP (relay)
1812 Routers
1858 IP Fragment Filtering
2131 DHCP (server and relay)
2338 VRRP
3021 31-bit Prefixes
3046 DHCP Option 82
3069 Private VLAN
3128 Tiny Fragment Attack Protection

General IPv6 Protocols
1981 Path MTU Discovery (partial)
2460 IPv6
2461 Neighbor Discovery (partial)
2462 Stateless Address Autoconfiguration (partial)
2463 ICMPv6
2464 Ethernet Transmission
2675 Jumbograms
3587 Global Unicast Address Format
4291 Addressing

RIP
1058 RIPv1
2453 RIPv2

OSPF
1587 NSSA
2154 MD5
2328 OSPFv2
2370 Opaque LSA
2740 OSPFv3
3623 Graceful Restart
4222 Prioritization and Congestion Avoidance

BGP
1997 Communities
2385 MD5
2439 Route Flap Damping
2545 Multiprotocol Extensions for IPv6
2796 Route Reflection
2842 Capabilities
2858 Multiprotocol Extensions
2918 Route Refresh
3065 Confederations
4360 Extended Communities
4893 4-byte ASN
5396 4-byte ASN Representation
draft-ietf-idr-bgp4-20 BGPv4
draft-ietf-idr-restart-06 Graceful Restart

Multicast
1112 IGMPv1
2236 IGMPv2
3376 IGMPv3
3569 SSM for IPv4
4541 IGMPv1/v2 Snooping
draft-ietf-pim-sm-v2-new-05 PIM-SM for IPv4

Network Management
1155 SMIv1
1156 Internet MIB
1157 SNMPv1
1212 Concise MIB Definitions
1215 SNMP Traps
1493 Bridges MIB
1850 OSPFv2 MIB
1901 Community-based SNMPv2
2011 IP MIB
2012 TCP MIB
2013 UDP MIB
2024 DLSw MIB
2096 IP Forwarding Table MIB
2570 SNMPv3
2571 Management Frameworks
2572 Message Processing and
Dispatching
2574 SNMPv3 USM
2575 SNMPv3 VACM
2576 Coexistence Between SNMPv1/v2/v3
2578 SMIv2
2579 Textual Conventions for SMIv2
2580 Conformance Statements for SMIv2
2618 RADIUS Authentication MIB
2665 Ethernet-like Interfaces MIB
2674 Extended Bridge MIB
2787 VRRP MIB
2819 RMON MIB (groups 1, 2, 3, 9)
2863 Interfaces MIB
2865 RADIUS
3273 RMON High Capacity MIB
3376 IGMPv3
3416 SNMPv2
3418 SNMP MIB
3434 RMON High Capacity Alarm MIB
3580 802.1X with RADIUS
5060 PIM MIB
ANSI/TIA-1057 LLDP-MED MIB
draft-grant-tacacs-02 TACACS+
draft-ietf-idr-bgp4-mib-06 BGP MIBv1
IEEE 802.1AB LLDP MIB, LLDP DOT1 MIB, LLDP DOT3 MIB
ruzin-mstp-mib-02 MSTP MIB (traps)
sFlow.org sFlowv5
sFlow.org sFlowv5 MIB
(version 1.3)
Dell Networking-BGP4-V2-MIB
Dell Networking-CS-CHASSIS-MIB
Dell Networking-IF-EXTENSION-MIB
Dell Networking-LINKAGG-MIB
Dell Networking-COPY-CONFIG-MIB
Dell Networking-MON-MIB
Dell Networking-PRODUCTS-MIB
Dell Networking-SMI
Dell Networking-SYSTEM-COMPONENT-MIB
Dell Networking-TC-MIB
Dell Networking-TRAP-ALARM-MIB

IEEE Compliance
802.1AB LLDP
802.1D Bridging, STP
802.1p L2 Prioritization
802.1Q VLAN Tagging, Double VLAN Tagging, GVRP
802.1s MSTP
802.1w RSTP
802.1X Network Access Control
802.3ab Gigabit Ethernet (1000BASE-T)
802.3ac Frame Extensions for VLAN Tagging
802.3ad Link Aggregation with LACP
802.3ae 10 Gigabit Ethernet (10GBASE-X)
802.3af Power over Ethernet
802.3ak 10 Gigabit Ethernet (10GBASE-CX4)802.3ba 40 Gigabit Ethernet (40GBase-SR4, 40GBase-CR4, 40GBase-LR4) on optical ports802.3i Ethernet (10BASE-T)
802.3u Fast Ethernet
(100BASE-FX, 100BASE-TX)
802.3x Flow Control
802.3z Gigabit Ethernet (1000BASE-X)
ANSI/TIA-1057 LLDP-MED
Dell Networking FRRP (Dell Networking Redundant Ring Protocol)
Dell Networking PVST+
MTU 9,252 bytes

Chassis

C7004  

4 line card slots
2 Route processor module with integrated switch fabric slots
6 Power supply module slots and 1 fan tray slot
Size: 9 RU, 15.7 h x 17.5 w x 15.3" d (39.88 h x 44.45 w x 38.86 cm d)
Weight with factory-installed components: 38 lbs (17.24 kg)
Weight fully loaded: 86.63 lbs (39.29 kg)
ISO 7779 A-weighted sound pressure level: 69.3 dBA at 73.4°F (23°C)
19" front rack mountable

 

C7008

8 line card slots
2 Route processor module with integrated switch fabric slots
8 Power supply module slots and 1 fan tray slot
Size:13 RU, 22.7 h x 17.4 w x 14.4" d (57.66 h x 44.2 w x 37.58 cm d)
Weight with factory-installed components: 55 lbs (24.95 kg)
Weight fully loaded: 152.27 lbs (69.07 kg)
ISO 7779 A-weighted sound pressure level: 73.8 dBA at 73.4°F (23°C)

Environmental

Maximum operating specifications:
Temperature: 32° to 104°F
(0° to 40°C)
Altitude: no performance degradation to 10,000 feet (3,048 meters)
Relative humidity: 5 to 85% (RH), non-condensing
Maximum non-operating specifications:
Temperature: -40° to 158°F
(-40° to 70°C)
Maximum altitude: 15,000 feet (4,572 meters)
Relative humidity: 5 to 95% (RH), non-condensing

Power

AC Power

C7004:
Nominal input voltage: 100–240 VAC 50/60 Hz

1600W PSU:

Maximum thermal output: 5,618 BTU/h at 100/120 VAC
5,304 BTU/h at 200/240 VAC
Maximum input current per module:
14 A at 100 VAC, 11 A at 120 VAC, 9 A at 200 VAC, 7 A at 240 VAC
Maximum system power input:
6,897 KVA at 100/120 VAC, 7,315 KVA at 200/240 VAC
Maximum power consumption:
1,647 W at 100/120 VAC, 1,555 W at 200/240 VAC

1200W PSU:
Maximum thermal output: 4,449 BTU/h (862 W) at 100/120 VAC
4,122 BTU/h (840 W) at 200/240 VAC
Maximum input current per module:
14 A at 100 VAC, 11 A at 120 VAC, 7 A at 200 VAC, 6 A at 240 VAC
Maximum system power input:
4,261 KVA at 100/120 VAC, 4,165 KVA at 200/240 VAC Maximum power consumption:
1,304 W at 100/120 VAC, 1,208 W at 200/240 VAC

C7008:
Nominal input voltage: 100–240 VAC 50/60 Hz

1600W PSU:
Maximum thermal output: 9,235 BTU/h at 100/120 VAC
9,299 BTU/h at 200/240 VAC
Maximum input current per module:
14 A at 100 VAC, 11 A at 120 VAC, 9 A at 200 VAC, 7 A at 240 VAC
Maximum system power input:
9,667 KVA at 100/120 VAC, 12,596 KVA at 200/240 VAC
Maximum power consumption:
2,707 W at 100/120 VAC, 2,726 W at 200/240 VAC

1200W PSU:
Maximum thermal output: 8,055 BTU/h at 100/120 VAC
7,420 BTU/h at 200/240 VAC
Maximum input current per module:
14 A at 100 VAC, 12 A at 120 VAC, 7 A at 200 VAC, 6 A at 240 VAC
Maximum system power input:
8,274 KVA at 100/120 VAC, 8,088 KVA at 200/240 VAC
Maximum power consumption:
2,361 W at 100/120 VAC, 2,175 W at 200/240 VAC
Maximum thermal output: 4,449 BTU/h (862 W) at 100/120 VAC
4,122 BTU/h (840 W) at 200/240 VAC
Maximum input current per module:
14 A at 100 VAC, 11 A at 120 VAC, 7 A at 200 VAC, 6 A at 240 VAC
Maximum system power input:
4,261 KVA at 100/120 VAC, 4,165 KVA at 200/240 VAC
Nominal Input Voltage: 100/120 VAC 50/60 Hz and 200/240 VAC 50/60 Hz
Max input current per power supply @ 1,450W (100/120V): 16A at 100V, 14A at 120V
Max input current per power supply @ 2,900W (200/240V): 16A at 200V, 14A at 240V
Max system power input (using 4 power supplies): 2,950 VA
Max. power consumption: 2,950W
Max. thermal output: 10,066 BTU/hr
Typ. power consumption: 1410-2400 Watts fully loaded, depending on line cards installed

Regulatory

Regulatory Compliance

Safety
UL/CSA 60950-1
EN 60950-1
IEC 60950-1 Including all National Deviations and Group Differences
EN 60825-1 Safety of Laser Products Part 1: Equipment Classification Requirements and User's Guide
EN 60825-2 Safety of Laser Products Part 2: Safety of Optical Fibre Communication Systems
FDA Regulation 21 CFR 1040.10 and 1040.11

Emissions
Australia/New Zealand: AS/NZS CISPR 22: Class A
Canada: ICES-003, Issue-4, Class A
Europe: EN 55022 (CISPR 22), Class A
Japan: VCCI Class A
USA: FCC CFR 47 Part 15, Subpart B, Class A

Immunity
EN 300 386: EMC for Network Equipment
EN 55024
EN 61000-3-2: Harmonic Current Emissions
EN 61000-3-3:Voltage Fluctuations and Flicker
EN 61000-4-2: ESD
EN 61000-4-3: Radiated Immunity
EN 61000-4-4: EFT
EN 61000-4-5: Surge
EN 61000-4-6: Low Frequency Conducted Immunity

RoHS
All C-Series components are EU RoHS compliant.
Models available with US Trade Agreements Act (TAA) compliance

Product Safety, EMC and Environmental Datasheets
Dell Regulatory Compliance Home Page
Dell and the Environment

Safety
UL/CSA 60950-1, Second Edition
EN 60950-1, Second Edition
IEC 60950-1, Second Edition Including All
National Deviations and Group Differences
EN 60825-1 Safety of Laser Products
Part 1: Equipment Classification Requirements and User’s Guide
EN 60825-2 Safety of Laser Products
Part 2: Safety of Optical Fibre Communication Systems
FDA Regulation 21 CFR 1040.10 and 1040.11

Emissions
Australia/New Zealand: AS/NZS CISPR 22: Class A
Canada: ICES-003, Issue-4, Class A
Europe: EN 55022: (CISPR 22:), Class A
Japan: VCCI Class A
USA: FCC CFR 47 Part 15, Subpart B: Class A

Immunity
EN 300 386 EMC for Network Equipment
EN 55024
EN 61000-3-2: Harmonic Current Emissions
EN 61000-3-3: Voltage Fluctuations and Flicker
EN 61000-4-2: ESD
EN 61000-4-3: Radiated Immunity
EN 61000-4-4: EFT
EN 61000-4-5: Surge
EN 61000-4-6: Low Frequency Conducted Immunity

RoHS
All C Series components are EU RoHS compliant.

Certifications
Available with US Trade Agreements Act (TAA) compliance
USGv6 Host and Router Certified on Dell Networking OS 9.5 and greater*
IPv6 Ready for both Host and Router*
UCR DoD APL (core and distribution ALSAN switch)*

*USGv6, IPv6 Ready, and UC APL certifications contingent upon successful test completion[DS1]

Product Safety, EMC and Environmental Datasheets
Dell Regulatory Compliance Home Page
Dell and the Environment

Port Attributes

Up to 60 40GbE QSFP+ ports

Up to 248 10GbE ports (240 SFP+ or 10GBASE-T ports plus eight SFP+ ports on two RPMs)

Support for 2,000 virtual ports (via rapid access nodes), and concurrent support for traditional Ethernet switches/devices

C9010 network director:
10 slot, includes 1x RPM, 1x AC PSU, 3x Fan

Modules:
C9010 Modular Switch, 10 slot, includes 1x RPM, 1x AC PSU, 3x Fan Modules, TAA

Redundant RPM:
C9000 RPM 2.56T, Redundant RPM

Line cards:
C9000 24-port 10GbE 10GBASE-T Line Card
C9000 24-port 10GbE SFP+ Line Card
C9000 6-port 40GbE QSFP+ Line Card

Redundant power supplies:

C9000 2,900W Power Supply

Fans:
C9000 Hot Swappable Fan Module

C1048P rapid access node:
48x 10/100/1000BASE-T PoE+ ports, 2x SFP+ ports, 2x stacking ports, 1 integrated 1000W power supply (requires C15 plug)

Hardware

C9010:
Up to 240 line-rate1 1/10GBASE-T ports
Up to 248 line-rate1 1/10GbE SFP+ ports
Up to 60 line-rate1 40GbE QSFP+ ports
3 fan modules
4 2,900W power supplies
Up to 2 RPMs
1 RJ45 console/management port with RS232 signaling and 1 USB-B port (per RPM)
Size: 8 RU, 13.9”h x 17.4” w x 18.0” d (35.26 cm h x 44.20 cm w x 45.70 cm d)
Weight: 55.4 lbs (25.2 kg) empty, 151.3 to 165.3 lbs (68.8 to 75.1 kg) fully loaded, depending on line cards installed

C1048P:
48 10/100/1000BASE-T RJ45 PoE+
2 integrated SFP+ uplink ports
2 integrated 21Gbps stack ports
Console/management port with RS232 signaling USB-A port
Size: 1 RU, 1.7”h x 17.3” w x 10.1” d (4.4 cm h x 44.0 cm w x 38.7 cm d)
Weight: 15.0 lbs (6.8 kg)

Environmental Operating Conditions

C9010P:
Max. operating specifications:
Operating temperature: 32° to 113°F (0° to 45°C)
Operating humidity: 5 to 85% (RH), noncondensing
Operating altitude: 0ft to 10,000ft above sea level
Max. non-operating specifications:
Storage temperature: –40° to 158°F (–40° to 70°C)
Storage humidity: 5 to 95% (RH), non-condensing

C1048P:
Max. operating specifications:
Operating temperature: 32° to 113°F (0° to 45°C)
Operating humidity: 5 to 95% (RH), noncondensing
Operating altitude: 0ft to 10,000ft above sea level
Max. non-operating specifications:
Storage temperature: –40° to 149°F (–40° to 65°C)
Storage humidity: 5 to 95% (RH), non-condensing
PoE/PoE+ Power Budget: 850W using integrated
power supply. 1,700W when used in conjunction with MPS1000

close
 
 
P21-CS05