Next-generation 10GbE iSCSI SAN arrays designed for growing environments
PS4110EImprove storage capacity, performance and connectivity for your small or midsize business with cost-effective EqualLogic™ PS4110E 10GbE iSCSI SAN arrays. View Details | PS4110XEnhance your remote and branch office data centers with high-performance, high-capacity and cost-effective Dell™ EqualLogic™ PS4110X 10GbE iSCSI arrays. View Details | PS4110XVConsolidate your remote office storage needs with the strong random IOPS performance of the Dell™ EqualLogic™ PS4110XV 10GbE iSCSI arrays View Details | PS4110XV 3.5”Enhance your enterprise data center with the 10GbE performance, high capacity and cost-effectiveness of Dell™ EqualLogic™ PS4110XV 3.5” 10GbE iSCSI arrays. View Details |
GREAT FOR
Small to midsize businesses and remote or branch offices seeking cost-effective, high-capacity 10GbE iSCSI SAN arrays for their growing storage needs. | Balancing cost-effectiveness with high-performance, high-capacity and 10GbE throughput for remote and branch office data centers | Remote office mid-tier scale-out iSCSI storage consolidation and other applications requiring strong random IOPS performance. | Helping control costs when building high-performance, high-capacity enterprise data centers |
Product Configurations
| Storage Controllers Dual controllers, each with 4GB memory for PS-series firmware. Each controller provides cache to flash for data protection. Hard Disk Drives Twelve (12) 7.2K NL-SAS hot-pluggable hard drives. Drive Capacities 3.5" 7,200 RPM NL-SAS drives available in 1 TB, 2 TB or 3 TB (3TB also available in NL-SAS SED) System Capacities 12 TB using twelve (12) 1 TB NL-SAS disk drives 24 TB using twelve (12) 2 TB NL-SAS disk drives 36 TB using twelve (12) 3 TB NL-SAS disk drives or NL-SAS SED disk drives | Storage Controllers Dual controllers, each with 4GB* memory for PS-series firmware. Each controller provides cache to flash for data protection. Hard Disk Drives Twenty-four (24) 10K SAS hot-pluggable hard disk drives Drive Capacities 2.5" 10,000 RPM SAS drives available in 300 GB, 600 GB and 900 GB System Capacities 7.2 TB* using twenty-four (24) 300 GB 10,000 SAS disk drives 14.4 TB using twenty-four (24) 600 GB 10,000 SAS disk drives 21.6 TB using twenty-four (24) 900 GB 10,000 SAS disk drives | Storage Controllers Dual controllers, each with 4GB memory for PS-series firmware. Each controller provides cache to flash for data protection. Hard Disk Drives Twenty-four (24) 15K SAS hot-pluggable hard disk drives Drive Capacities 2.5" 15,000 RPM SAS drives available in 146 GB or 300GB System Capacities 3.5 TB using twenty-four (24) 146GB* 15,000 SAS disk drives 3.6 TB using twelve (12) 300GB* 15,000 SAS disk drives 7.2 TB using twenty-four (24) 300GB* 15,000 SAS disk drives | Storage Controllers Dual controllers, each with 4GB* memory for PS-series firmware. Each controller provides cache to flash for data protection. Hard Disk Drives Twelve (12) 15K SAS hot-pluggable hard drives. Drive Capacities 3.5" 15,000 RPM SAS or SAS SED drives available in 600 GB* System Capacities 3.6 TB* using six (6) 600 GB 15,000 SAS or SAS SED disk drives 7.2 TB* using twelve (12) 600 GB 15,000 SAS or SAS SED disk drives |
Technical Highlights
| Volumes Up to 256 Snapshots 128 per volume / up to 2,048 total per group Volume Connections Up to 512 per pool / 1024 per group Host Protocol Any standards-compliant iSCSI initiator Operating Systems Supported Windows® 2000 Server, Windows Server® 2003, Windows Server® 2008, including Hyper-V™, Windows Vista®, Windows Server® 2008 R2 including Hyper-V™, Windows XP®, Red Hat® Enterprise Linux®, SUSE® Linux® Enterprise, Sun™ Solaris™, IBM® AIX®, HP-UX, Mac OS® X, VMware® ESX Server 3 / 3.5 / 4 / 4.1 / 5, ESXi 3.5 / 4 / 4.1 / 5 Citrix® XenServer™, Novell® NetWare® RAID Support RAID 5, RAID 6, RAID 10, and RAID 50 10GbE Network Interfaces 10GbE connectivity with one (1) 10GBASE-T with RJ45, one (1) 10GbE SFP+ for fiber or twin-ax copper cabling, and one (1) 100BASE-TX dedicated management port per controller TCP Network Support IPv4, IPv6 core support Expansion Option Can be combined with other EqualLogic PS Series arrays in the same SAN group, online. A maximum of two (2) PS4xx0 arrays can be in a group. | Volumes Up to 256 Snapshots 128 per volume / up to 2,048 total per group Volume Connections Up to 512 per pool / 1024 per group Host Protocol Any standards-compliant iSCSI initiator Operating Systems Supported Windows® 2000 Server, Windows Server® 2003, Windows Server® 2008, including Hyper-V™, Windows Vista®, Windows Server® 2008 R2 including Hyper-V™, Windows XP®, Red Hat® Enterprise Linux®, SUSE® Linux® Enterprise, Sun™ Solaris™, IBM® AIX®, HP-UX, Mac OS® X, VMware® ESX Server 3 / 3.5 / 4 / 4.1 / 5, ESXi 3.5 / 4 / 4.1 / 5, Citrix® XenServer™, Novell® NetWare® RAID Support RAID 5, RAID 6, RAID 10, and RAID 50 10GbE Network Interfaces 10GbE connectivity with one (1) 10GBASE-T with RJ45, one (1) 10GbE SFP+ for fiber or twin-ax copper cabling, and one (1) 100BASE-TX dedicated management port per controller TCP Network Support IPv4, IPv6 core support Expansion Option Can be combined with other EqualLogic PS Series arrays in the same SAN group, online. A maximum of two (2) PS4xx0 arrays can be in a group. | Volumes Up to 256 Snapshots 128 per volume / up to 2,048 total per group Volume Connections Up to 512 per pool / 1024 per group Host Protocol Any standards-compliant iSCSI initiator Operating Systems Supported Windows® 2000 Server, Windows Server® 2003, Windows Server® 2008, including Hyper-V™, Windows Vista®, Windows Server® 2008 R2 including Hyper-V™, Windows XP®, Red Hat® Enterprise Linux®, SUSE® Linux® Enterprise, Sun™ Solaris™, IBM® AIX®, HP-UX, Mac OS® X, VMware® ESX Server 3 / 3.5 / 4 / 4.1 / 5, ESXi 3.5 / 4 / 4.1 / 5, Citrix® XenServer™, Novell® NetWare® RAID Support RAID 5, RAID 6, RAID 10, and RAID 50 10GbE Network Interfaces 10GbE connectivity with one (1) 10GBASE-T with RJ45, one (1) 10GbE SFP+ for fiber or twin-ax copper cabling, and one (1) 100BASE-TX dedicated management port per controller TCP Network Support IPv4, IPv6 core support Expansion Option Can be combined with other EqualLogic PS Series arrays in the same SAN group, online. A maximum of two (2) PS4xx0 arrays can be in a group. | Volumes Up to 256 Snapshots 128 per volume / up to 2,048 total per group Volume Connections Up to 512 per pool / 1024 per group Host Protocol Any standards-compliant iSCSI initiator Operating Systems Supported Windows® 2000 Server, Windows Server® 2003, Windows Server® 2008, including Hyper-V™, Windows Vista®, Windows Server® 2008 R2 including Hyper-V™, Windows XP®, Red Hat® Enterprise Linux®, SUSE® Linux® Enterprise, Sun™ Solaris™, IBM® AIX®, HP-UX, Mac OS® X, VMware® ESX Server 3 / 3.5 / 4 / 4.1 / 5, ESXi 3.5 / 4 / 4.1 / 5, Citrix® XenServer™, Novell® NetWare® RAID Support RAID 5, RAID 6, RAID 10, and RAID 50 10GbE Network Interfaces 10GbE connectivity with one (1) 10GBASE-T with RJ45, one (1) 10GbE SFP+ for fiber or twin-ax copper cabling, and one (1) 100BASE-TX dedicated management port per controller TCP Network Support IPv4, IPv6 core support Expansion Option Can be combined with other EqualLogic PS Series arrays in the same SAN group, online. A maximum of two (2) PS4xx0 arrays can be in a group. |
Reliability
| Vertical port sharing Redundant hot-swappable controllers, power supplies / cooling fans, and hot-swappable disks Individual disk drive slot power control Cache-to-flash | Vertical port sharing Redundant hot-swappable controllers, power supplies / cooling fans, and hot-swappable disks Individual disk drive slot power control Cache-to-flash | Vertical port sharing Redundant hot-swappable controllers, power supplies / cooling fans, and hot-swappable disks Individual disk drive slot power control Cache-to-flash | Vertical port sharing Redundant hot-swappable controllers, power supplies / cooling fans, and hot-swappable disks Individual disk drive slot power control Cache-to-flash |
Enclosure Monitoring System
| Automatic spare configuration and utilization SMART Automatic bad block replacement Auto-Stat Disk Monitoring System (ADMS) to monitor health of data on disk drives | Automatic spare configuration and utilization SMART Automatic bad block replacement Auto-Stat Disk Monitoring System (ADMS) to monitor health of data on disk drives | Automatic spare configuration and utilization SMART Automatic bad block replacement Auto-Stat Disk Monitoring System (ADMS) to monitor health of data on disk drives | Automatic spare configuration and utilization SMART Automatic bad block replacement Auto-Stat Disk Monitoring System (ADMS) to monitor health of data on disk drives |
Management
| SAN Headquarters multi-group performance and event monitoring tool Serial console Ability to configure a separate management network SNMP, telnet, SSH, HTTP, Web (SSL), host scripting Multi-administrator support | SAN Headquarters multi-group performance and event monitoring tool Serial console Ability to configure a separate management network SNMP, telnet, SSH, HTTP, Web (SSL), host scripting Multi-administrator support | SAN Headquarters multi-group performance and event monitoring tool Serial console Ability to configure a separate management network SNMP, telnet, SSH, HTTP, Web (SSL), host scripting Multi-administrator support | SAN Headquarters multi-group performance and event monitoring tool Serial console Ability to configure a separate management network SNMP, telnet, SSH, HTTP, Web (SSL), host scripting Multi-administrator support |
Security
| CHAP authentication Access control for iSCSI Access control for management interfaces including RADIUS support | CHAP authentication Access control for iSCSI Access control for management interfaces including RADIUS support | CHAP authentication Access control for iSCSI Access control for management interfaces including RADIUS support | CHAP authentication Access control for iSCSI Access control for management interfaces including RADIUS support |
Notification Methods
| SNMP traps, e-mail, syslog | SNMP traps, e-mail, syslog | SNMP traps, e-mail, syslog | SNMP traps, e-mail, syslog |
Power
| AC voltage: 100-240 VAC ±10% single phase 700 W (max, total), +5V up to 155W; +12V up to 624W; +5Vsb up to 10W Frequency: 50/60 Hz Power factor: 0.98 (minimum) Power supplies: Dual 700 W | AC voltage: 700 W (max, total), +5V up to 155W; +12V up to 624W; +5Vsb up to 10W Frequency: 50/60 Hz Power factor: 0.98 (minimum) Power supplies: Dual 700 W | AC voltage: 100-240 VAC ±10% single phase 700 W (max, total), +5V up to 155W; +12V up to 624W; +5Vsb up to 10W Frequency: 50/60 Hz Power factor: 0.98 (minimum) Power supplies: Dual 700 W | AC voltage: 100-240 VAC ±10% single phase 700 W (max, total), +5V up to 155W; +12V up to 624W; +5Vsb up to 10W Frequency: 50/60 Hz Power factor: 0.98 (minimum) Power supplies: Dual 700 W |
Chassis
| Height: 2U / 8.68 cm (3.41 inches) Width: 44.63 cm (17.57 inches) Depth: 59.4 cm (23.4 inches) Weight: 27.67 kg (61 lbs) Packaged physical: Length: 851 cm (33.50 inches) Width: 629 cm (24.75 inches) Depth: 395 cm (15.56 inches) Packaged weight: 40.8261 Kg (90 lb) Rack Support Dell ReadyRails™ sliding rails for square-hole 4-post and 2-post racks 1U/2U Rail Attachment Brackets, designed to enable PS Arrays to snap into place with screws or other hardware Dell VersaRails sliding rails for 4-post and 2-post racks 1U/2U Rail Attachment Brackets, designed to enable PS Arrays to be mounted in racks whose posts have round holes | Height: 2U / 8.68 cm (3.41 inches) Width: 44.63 cm (17.57 inches) Depth: 54.1 cm (21.3 inches) Weight: 25.4 kg (56 lbs) Packaged physical: Length: 851 cm (33.50 inches) Width: 629 cm (24.75 inches) Depth: 395 cm (15.56 inches) Packaged weight: 37.1973 Kg (82 lb) Rack Support Dell ReadyRails™ sliding rails for square-hole 4-post and 2-post racks 1U/2U Rail Attachment Brackets, designed to enable PS Arrays to snap into place with screws or other hardware Dell VersaRails sliding rails for 4-post and 2-post racks 1U/2U Rail Attachment Brackets, designed to enable PS Arrays to be mounted in racks whose posts have round holes | Height: 2U / 8.68 cm (3.41 inches) Width: 44.63 cm (17.57 inches) Depth: 54.1 cm (21.3 inches) Weight: 25.4 kg (56 lbs) Packaged physical: Length: 851 cm (33.50 inches) Width: 629 cm (24.75 inches) Depth: 395 cm (15.56 inches) Packaged weight: 37.1973 Kg (82 lb) Rack Support Dell ReadyRails™ sliding rails for square-hole 4-post and 2-post racks 1U/2U Rail Attachment Brackets, designed to enable PS Arrays to snap into place with screws or other hardware Dell VersaRails sliding rails for 4-post and 2-post racks 1U/2U Rail Attachment Brackets, designed to enable PS Arrays to be mounted in racks whose posts have round holes | Height: 2U / 8.68 cm (3.41 inches) Width: 44.63 cm (17.57 inches) Depth: 59.4 cm (23.4 inches) Weight: 27.67 kg (61 lbs) Packaged physical: Length: 851 cm (33.50 inches) Width: 629 cm (24.75 inches) Depth: 395 cm (15.56 inches) Packaged weight: 40.8261 Kg (90 lb) Rack Support Dell ReadyRails™ sliding rails for square-hole 4-post and 2-post racks 1U/2U Rail Attachment Brackets, designed to enable PS Arrays to snap into place with screws or other hardware Dell VersaRails sliding rails for 4-post and 2-post racks 1U/2U Rail Attachment Brackets, designed to enable PS Arrays to be mounted in racks whose posts have round holes |
Environmental Operating Conditions
| Temperature range: 5° to 40°C (41° to 104°F) Storage temperature: –40° to 65°C (–40° to 149°F) Altitude: For altitudes above 2950 feet, the maximum operating temperature is derated 1ºF/550 ft. Relative humidity: 20% to 80% (noncondensing) with a maximum humidity gradation of 10% per hour Shock: Half-sine shock 31G +/- 5% with a pulse duration of 2.6ms +/- 10% in operational orientations only Vibration: 0.26 Grms (5 to 350 Hz) for 5 minutes in operational orientations Acoustics Category 4: <=7.2 bels at 23C +/- 2C Air Quality: Airborne contaminant level of G1 or lower as defined by ISA-S71.04-1985 | Temperature range: 5° to 40°C (41° to 104°F) Storage temperature: –40° to 65°C (–40° to 149°F) Altitude: For altitudes above 2950 feet, the maximum operating temperature is derated 1ºF/550 ft. Relative humidity: 20% to 80% (noncondensing) with a maximum humidity gradation of 10% per hour Shock: Half-sine shock 31G +/- 5% with a pulse duration of 2.6ms +/- 10% in operational orientations only Vibration: 0.26 Grms (5 to 350 Hz) for 5 minutes in operational orientations Acoustics Category 4: <=7.2 bels at 23C +/- 2C Air Quality: Airborne contaminant level of G1 or lower as defined by ISA-S71.04-1985 | Temperature range: 5° to 40°C (41° to 104°F) Storage temperature: –40° to 65°C (–40° to 149°F) Altitude: For altitudes above 2950 feet, the maximum operating temperature is derated 1ºF/550 ft. Relative humidity: 20% to 80% (noncondensing) with a maximum humidity gradation of 10% per hour Shock: Half-sine shock 31G +/- 5% with a pulse duration of 2.6ms +/- 10% in operational orientations only Vibration: 0.26 Grms (5 to 350 Hz) for 5 minutes in operational orientations Acoustics Category 4: <=7.2 bels at 23C +/- 2C Air Quality: Airborne contaminant level of G1 or lower as defined by ISA-S71.04-1985 | Temperature range: 5° to 40°C (41° to 104°F) Storage temperature: –40° to 65°C (–40° to 149°F) Altitude: For altitudes above 2950 feet, the maximum operating temperature is derated 1ºF/550 ft. Relative humidity: 20% to 80% (noncondensing) with a maximum humidity gradation of 10% per hour Shock: Half-sine shock 31G +/- 5% with a pulse duration of 2.6ms +/- 10% in operational orientations only Vibration: 0.26 Grms (5 to 350 Hz) for 5 minutes in operational orientations Acoustics Category 4: <=7.2 bels at 23C +/- 2C Air Quality: Airborne contaminant level of G1 or lower as defined by ISA-S71.04-1985 |