Problem: On a PowerEdge M1000e™ the AC blade consumption displayed on the GUI doesn’t take into account more efficient PSU modes afforded by the Dynamic Power Supply Engagement (DPSE) power optimization function.

Discussion: Chassis Management Controller (CMC) GUI power readings use fixed conversion efficiency, 85.3%, while a dynamic efficiency is calculated and delivered to iDRAC for power plotting that varies between 73.2% and 91.2%. The GUI readings don’t take DPSE efficiencies into account.


Answer

Do not replace hardware. The value of GUI scaling is modest for the user.



 


Quick Tips content is self-published by the Dell Support Professionals who resolve issues daily. In order to achieve a speedy publication, Quick Tips may represent only partial solutions or work-arounds that are still in development or pending further proof of successfully resolving an issue. As such Quick Tips have not been reviewed, validated or approved by Dell and should be used with appropriate caution. Dell shall not be liable for any loss, including but not limited to loss of data, loss of profit or loss of revenue, which customers may incur by following any procedure or advice set out in the Quick Tips.

Artikel-id: SLN285553

Laatste wijzigingsdatum: 11/06/2013 12:00 AM


Beoordeel dit artikel

Nauwkeurig
Nuttig
Eenvoudig te begrijpen
Was dit artikel nuttig?
Ja Nee
Stuur ons feedback
Opmerkingen mogen geen speciale tekens bevatten: <>() \
Excuses, ons feedbacksysteem is momenteel offline. Probeert u het later nog eens.

Hartelijk dank voor uw feedback.