Databáze znalostí

PowerEdge C410x IPMI commands for Linux and Windows



This article describes how to remotely manage your PowerEdge C410x


These commands will allow you to be able to remotely manage your C410x chassis via the BMC port on the chassis.

BMC updates have enhanced the functionality of these commands, so make sure they are up to date.


Following is a list of Linux commands:
*Note* For these commands to work, IPMITool must be installed and the IPMI service must be running.


C410x, C6100, & C6145 Chassis Power On/Off

ipmitool –H <ip.address> –U root –P root chassis power on
ipmitool –H <ip.address> –U root –P root chassis power off

C410x, C6100, & C6145 Check Chassis Power Status
ipmitool –H <ip.address> –U root –P root chassis power status

C410x sensor readings (Temp, Watt, FAN)
ipmitool –H <ip.address> –U root –P root sensor list

If you want to list all temperatures sensors:
ipmitool sensor list | grep Temp

If you just want to get reading of specific slot:
ipmitool sensor reading "PCIE 1 Temp"

ipmitool sensor reading "PCIE 16 Temp"

Read power status of each slot:
ipmitool sensor reading "PCIE 1 Watt"

ipmitool sensor reading "PCIE 16 Watt"

C410x power control for individual slots:
ipmitool –H <ip.address> –U root –P root raw 0x30 0xF0 0x01 0x00 ---Toggle Slot 1 power state

ipmitool –H <ip.address> –U root –P root raw 0x30 0xF0 0x00 0x80 ---Toggle Slot 16 power state

Please assert one bit (one slot power) at one time.
Slot 1- 0x01 0x00
Slot 2- 0x02 0x00
Slot 3- 0x04 0x00
Slot 4- 0x08 0x00
Slot 5- 0x10 0x00
Slot 6- 0x20 0x00
Slot 7- 0x40 0x00
Slot 8- 0x80 0x00
Slot 9- 0x00 0x01
Slot 10- 0x00 0x02
Slot 11- 0x00 0x04
Slot 12- 0x00 0x08
Slot 13- 0x00 0x10
Slot 14- 0x00 0x20
Slot 15- 0x00 0x40
Slot 16- 0x00 0x80

Following is a list of Windows commands:
*Note* For these commands to work, IPMIUtil must be installed and running.


C410x, C6100, & C6145 Chassis Power On/Off
ipmiutil power -u –N <ip.address> –U root –P root ---chassis power on

ipmiutil power -d –N <ip.address> –U root –P root ---chassis power off

C410x, C6100, & C6145 Check Chassis Power Status
ipmiutil health –N <ip.address> –U root –P root

C410x sensor readings (Temp, Watt, FAN)
ipmiutil sensor –N <ip.address> –U root –P root

If you just want to get reading of specific slot:
ipmiutil sensor -i 0x09 -N <ip.address> -U root -P root ---sensor reading "PCIE 1 Temp"

ipmiutil sensor -i 0x18 -N <ip.address> -U root -P root ---sensor reading "PCIE 16 Temp"

Read power status of each slot.
ipmiutil sensor -i 0x19 -N <ip.address> -U root -P root ---sensor reading "PCIE 1 Watt"

ipmiutil sensor -i 0x28 -N <ip.address> -U root -P root ---sensor reading "PCIE 16 Watt"

C410x power control for individual slots
ipmiutil cmd –N <ip.address> –U root –P root 00 20 c0 F0 01 00 ---Toggle Slot 1 power state

ipmiutil cmd –N <ip.address> –U root –P root 00 20 c0 F0 00 80 ---Toggle Slot 16 power state

Please assert one bit (one slot power) at one time.
Slot 1- 01 00
Slot 2- 02 00
Slot 3- 04 00
Slot 4- 08 00
Slot 5- 10 00
Slot 6- 20 00
Slot 7- 40 00
Slot 8- 80 00
Slot 9- 00 01
Slot 10- 00 02
Slot 11- 00 04
Slot 12- 00 08
Slot 13- 00 10
Slot 14- 00 20
Slot 15- 00 40
Slot 16- 00 80




Quick Tips content is self-published by the Dell Support Professionals who resolve issues daily. In order to achieve a speedy publication, Quick Tips may represent only partial solutions or work-arounds that are still in development or pending further proof of successfully resolving an issue. As such Quick Tips have not been reviewed, validated or approved by Dell and should be used with appropriate caution. Dell shall not be liable for any loss, including but not limited to loss of data, loss of profit or loss of revenue, which customers may incur by following any procedure or advice set out in the Quick Tips.

ID článku: SLN244176

Datum poslední změny: 10/09/2014 11:27 AM


Zhodnoťte tento článek

Přesné
Užitečné
Snadno srozumitelné
Byl tento článek užitečný?
Ano Ne
Zašlete nám svůj názor
Komentáře nesmí obsahovat tyto speciální znaky: <>() \
Je nám líto, ale náš systém zpětné vazby je v současné době mimo provoz. Zkuste to později.

Děkujeme za váš názor.