Videnbase

13G PowerEdge Servers boots with a Shadow Memory Error


The following BIOS POST message can be displayed :

Unable to load one of more option ROMs because of insufficient shadow memory.


In a system with multiple NIC interfaces and with all (or most) of the PCIe devices with Option ROMs enabled, the system may POST with the error message similar to this



This is not an hardware failure.

Typically only one or two devices should have the option rom enabled.

Solution


Reboot the server and enter the PCIe card configuration menu (CTRL+S during P.O.S.T.), in the menu, disable the devices' option ROMs that are not needed to be bootable.

There is also an option to disable the Boot Driver Support for PCIe slots in the BIOS Integrated Devices menu.

Possibly the Memory Mapped I/O above 4GB must be disabled, too. (Enter BIOS via F2 -> Sytem BIOS -> Integrated Devices). This is recommended for ESXi OS.

If the BIOS is in UEFI mode this problem does not exist.





Need more help?
Find additional PowerEdge and PowerVault articles

Visit and ask for support in our Communities

Create an online support Request


Artikelnummer: SLN292991

Sidste ændringsdato: 06/09/2016 08:52 AM


Bedøm denne artikel

Nøjagtig
Nyttig
Nemt at forstå
Var denne artikel nyttig?
Ja Nej
Send os feedback
Kommentarer må ikke indeholde følgende specialtegn: <>()\