Consulta de temas

DRAC - iDRAC6 Modular vFlash Partition Reports "Partition is busy" After Upload or Download Failure


Article Summary: This article provides information on iDRAC6 modular vFlash partition reports "Partition is busy" after upload or download failure.



Question

If there is a network disconnection or failure during a vflash upload or download operation in the idrac6 modular web GUI, the partiton that is being used can get stuck in a busy state.

Note: The issue only occurs when using the idrac6 modular web GUI. There is no impact to RACADM or WSMAN interfaces.


Answer

To clear the busy state. and make the vFlash partition available again, the iDRAC6 must be reset using RACADM, web GUI, or WSMAN. (i.e. racadm racreset)



 


Quick Tips content is self-published by the Dell Support Professionals who resolve issues daily. In order to achieve a speedy publication, Quick Tips may represent only partial solutions or work-arounds that are still in development or pending further proof of successfully resolving an issue. As such Quick Tips have not been reviewed, validated or approved by Dell and should be used with appropriate caution. Dell shall not be liable for any loss, including but not limited to loss of data, loss of profit or loss of revenue, which customers may incur by following any procedure or advice set out in the Quick Tips.

Identificación del artículo: SLN283092

Última fecha de modificación: 09/27/2013 12:00 AM


Califique este artículo

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
No
Envíenos sus comentarios
Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"
Disculpe, nuestro sistema de comentarios está actualmente inactivo. Vuelva a intentarlo más tarde.

Muchas gracias por sus comentarios.