Improper SCSI Termination Causes POST Error on the Dell™ PowerVault™ 120T DLT1 Autoloader. - KB Article - 150558


Check the plug-in terminator on the back of the autoloader.

There are two SCSI connectors on the back of the unit. One should have the cable attached and the other connector should have a SCSI terminator attached.



The Drive Must Be Terminated.

On a PowerVault 120T DLT1 Autoloader, the drive must be terminated in order for the unit to complete POST. If the drive is not properly terminated, the LCD displays the error message LDR INIT and the alarm sounds with a solid beep.

The PowerVault 120T Autoloader DLT1 is an LVD SCSI device. SCSI devices require termination on each end of the SCSI bus. The termination for this device is in the form of a plug-in terminator on the PowerVault 120T.



 


Quick Tips content is self-published by the Dell Support Professionals who resolve issues daily. In order to achieve a speedy publication, Quick Tips may represent only partial solutions or work-arounds that are still in development or pending further proof of successfully resolving an issue. As such Quick Tips have not been reviewed, validated or approved by Dell and should be used with appropriate caution. Dell shall not be liable for any loss, including but not limited to loss of data, loss of profit or loss of revenue, which customers may incur by following any procedure or advice set out in the Quick Tips.