System Messages | ||
---|---|---|
Message | Causes | Corrective Actions |
Alert! Redundant memory disabled! Memory configuration does not support redundant memory. | Installed memory modules are not the same type and size; faulty memory module(s). | Ensure that all memory modules are of the same type and size, and that they are properly installed. Remember you can POST with one DIMM to test memory function. |
Attempting to update Remote Configuration. Please wait... | Remote Configuration request has been detected and is being processed. | Wait until the process is complete. |
BIOS Update Attempt Failed! | Remote BIOS update attempt failed. | Retry the BIOS update. If the problem persists, clear NVRAM and try again. |
Caution! NVRAM_CLR jumper is installed on system board. | NVRAM_CLR jumper is installed. CMOS has been cleared. | Remove the NVRAM_CLR jumper. |
CPUs with different cache sizes detected! | Microprocessors with different cache sizes are installed. | Ensure that all microprocessors have the same cache size, and that they are properly installed. |
Decreasing available memory | Faulty or improperly installed memory modules. | Check seating and test memory. |
DIMM pairs must be matched in size, speed, and technology. The following DIMM pair is mismatched: DIMM x and DIMM y. | Mismatched or unmatched DIMMs installed; faulty or improperly seated memory module(s). | Ensure that all pairs of memory modules are of the same type and size, and that they are properly installed. If the problem persists, test memory. |
DIMMs must be populated in sequential order beginning with slot 1. The following DIMM is electrically isolated: DIMM x. | The specified DIMM is inaccessible to the system due to its location. DIMMs must be populated in sequential order, beginning with slot 1. | Populate 2, 4, 8, or 12 DIMMs sequentially beginning with slot 1. Only the 2900 supports 12 DIMMs. |
DIMMs should be installed in pairs. Pairs must be matched in size, speed, and technology. | Mismatched or unmatched DIMMs installed; faulty or improperly seated memory module(s). The system will operate in a degraded mode with reduced ECC protection. Only memory installed in channel 0 will be accessible. | Ensure that all pairs of memory modules are of the same type and size, and that they are properly installed. If the problem persists, test memory. |
Dual-rank DIMM paired with Single-rank DIMM - The following DIMM/rank has been disabled by BIOS: DIMM x Rank y | Mismatched DIMMs installed; faulty memory module(s). The system has detected a dual-rank DIMM paired with a single-rank DIMM. The second rank of the dual-rank DIMM will be disabled. | Ensure that all pairs of memory modules are of the same type and size, and that they are properly installed. If the problem persists, test memory. |
Diskette drive n seek failure | Incorrect configuration settings in the System Setup program. Faulty or improperly installed diskette drive. Loose diskette drive interface cable, or loose power cable. |
Run the System Setup program to correct the settings. Reseat diskette drive interface cable, or power cable. If the problem persists, test the diskette drive. |
Diskette read failure | Faulty or improperly inserted diskette. | Replace the diskette. If the problem persists, test the diskette drive with known working media. |
Diskette subsystem reset failed | Faulty or improperly installed diskette. | Replace the diskette. If the problem persists, test the diskette drive with known working media. |
Drive not ready | Diskette missing from or improperly inserted in diskette drive. | Replace the diskette. If the problem persists, test the diskette drive with known working media. |
Error: Incorrect memory configuration. DIMMs must be installed in pairs of matched memory size, speed, and technology. | Mismatched or unmatched DIMMs installed; faulty or improperly seated memory module(s). | Ensure that all pairs of memory modules are of the same type and size, and that they are properly installed. |
Error: Memory failure detected. Memory size reduced. Replace the faulty DIMM as soon as possible. | Faulty or improperly seated memory module(s). | Ensure that all pairs of memory modules are properly installed. If the problem persists, test memory DIMMs. |
!!*** Error: Remote Access Controller initialization failure*** RAC virtual USB devices may not be available... | Remote Access Controller initialization failure. | Ensure that the Remote Access Controller is properly installed. Checking cabling and connectors for damage. |
FBD training error - The following memory branch has been disabled: Branch x | Train error on DIMMs on the matching pair. If a channel fails to train, the paired channel will be disabled as well. | Correct the training error, start by checking the memory is properly installed. |
Gate A20 failure | Faulty keyboard controller; faulty system board. | Check keyboard connection. Swap with known good keyboard, SIP, or KVM cable. |
General failure | The operating system is unable to carry out the command. | This message is usually followed by specific information. Note the information and take the appropriate action to resolve the problem. |
Invalid NVRAM configuration, Resource Re-allocated | System detected and corrected a resource conflict. | No action is required, as the Re-allocated configuration is now correct. |
Keyboard Controller failure | Faulty keyboard controller; faulty system board | Try clearing NVRAM. |
Manufacturing mode detected | System is in manufacturing mode. | Reboot to take the system out of manufacturing mode. If the problem persists, clear NVRAM and reflash the BIOS/BMC. |
MEMBIST failure - The following DIMM/rank has been disabled by BIOS: DIMM x Rank y | Faulty memory module(s). | Ensure the DIMM x is installed in a pair of memory modules that are of the same type and size, and that they are properly installed. |
Memory address line failure at <address>, read <value> expecting <value> | Faulty or improperly installed memory modules. | Ensure that all pairs of memory modules are properly installed. If the problem persists, test memory DIMMs. |
Memory double word logic failure at <address>, read <value> expecting <value> | Faulty or improperly installed memory modules. | Ensure that all pairs of memory modules are properly installed. If the problem persists, test memory DIMMs. |
Memory odd/even logic failure at <address>, read <value> expecting <value> | Faulty or improperly installed memory modules. | Ensure that all pairs of memory modules are properly installed. If the problem persists, test memory DIMMs. |
Memory write/read failure at <address>, read <value> expecting <value> | Faulty or improperly installed memory modules. | Ensure that all pairs of memory modules are properly installed. If the problem persists, test memory DIMMs. |
Memory tests terminated by keystroke. | POST memory test terminated by pressing the spacebar. | Information only. |
No boot device available | Faulty or missing optical/diskette drive subsystem, hard drive, or hard-drive subsystem, or no boot disk in drive A. | Use a bootable diskette, CD, or hard drive with a readable MBR. Also check the setting of the boot ordering in the system BIOS and/or RAID controller. |
No boot sector on hard drive | Incorrect configuration settings in System Setup program, or no operating system on hard drive. | Check the hard-drive configuration settings in the System Setup program. Check boot order of RAID controller. Make sure an operating system was installed. |
No timer tick interrupt | Faulty system board. | Try clearing NVRAM or reflashing BIOS and BMC. |
Northbound merge error - The following DIMM has been disabled by BIOS: DIMM x | The specified DIMM was unable to establish a successful data link with the memory controller. | Ensure that all pairs of memory modules are of the same type and size, and that they are properly installed. If the problem persists, test memory. |
Not a boot diskette | No operating system on diskette. | Use a bootable diskette, remove floppy, or change boot order in system BIOS. |
PCIe Degraded Link Width Error: Embedded Bus<#nn>/Dev<#nn>/Func<n> Expected Link Width is <n> Actual Link Width is <n> |
Faulty or improperly installed PCIe card in the specified slot. | Reseat the PCIe card in the specified slot number. If problem persists, test PCIe card. |
PCIe Degraded Link Width Error: Slot <n> Expected Link Width is <n> Actual Link Width is <n> |
Faulty or improperly installed PCIe card in the specified slot. | Reseat the PCIe card in the specified slot number. If problem persists, test PCIe card. |
PCIe Training Error: Embedded Bus<#nn>/Dev<#nn>/Func<n> PCIe Training Error: Slot <n> |
Faulty or improperly installed PCIe card in the specified slot. | Reseat the PCIe card in the specified slot number. If problem persists, test PCIe card. |
PCI BIOS failed to install | PCI device BIOS (Option ROM) checksum failure is detected during shadowing. Loose cables to expansion card(s); faulty or improperly installed expansion card. | Reseat the expansion cards. Ensure that all appropriate cables are securely connected to the expansion cards. If the problem persists, test the PCI device. |
Plug & Play Configuration Error | Error encountered in initializing PCI device; faulty system board. | Install the NVRAM_CLR jumper and reboot the system. If the problem persists, pull all PCI devices and clear NVRAM again. |
Read fault Requested sector not found |
The operating system cannot read from the diskette or hard drive, the system could not find a particular sector on the disk, or the requested sector is defective. | Replace the diskette. Ensure that the diskette and hard drive cables are properly connected. Check the boot order in system BIOS and/or RAID controller. Scan disk for media defects. |
Remote configuration update attempt failed | System unable to process Remote Configuration request. | Check settings on Remote Configuration, and retry Remote Configuration. |
ROM bad checksum = address | Expansion card improperly installed or faulty. | Reseat the expansion cards. Ensure that all appropriate cables are securely connected to the expansion cards. If the problem persists, test the PCI device. |
Sector not found Seek error Seek operation failed |
Faulty diskette or hard drive. | Replace the diskette. Ensure that the diskette and hard drive cables are properly connected. Check the boot order in system BIOS and/or RAID controller. Scan disk for media defects. |
Shutdown failure | Shutdown test failure. | Ensure that all pairs of memory modules are properly installed. If the problem persists, test memory DIMMs. |
The amount of system memory has changed | Memory has been added or removed, or a memory module may be faulty. | If memory has been added or removed, this message is informative and can be ignored. If memory has not been added or removed, check the SEL to determine if single-bit or multi-bit errors were detected and replace the faulty memory module. |
The FBD link to the following DIMM failed to train: DIMM x | Faulty or improperly seated memory module(s). Possible faults in links between DIMMs. | Check the memory is properly installed. Swap affected channels with disabled channel of memory. Test memory one DIMM at a time. |
The following DIMM pair is not compatible with the memory controller: DIMM x and DIMM y | The specified DIMM(s) are incompatible with the system. | Ensure that only ECC FBD1 memory is used. Dell recommends purchasing memory upgrade kits directly from www.dell.com or your Dell sales agent to ensure compatibility. |
The following DIMMs are not compatible: DIMM x and DIMM y | The specified DIMM(s) are incompatible with the system. | Ensure that only ECC FBD1 memory is used. Dell recommends purchasing memory upgrade kits directly from www.dell.com or your Dell sales agent to ensure compatibility. |
Time-of-day clock stopped | Faulty battery or faulty chip. | Test CMOS battery by setting time and unplugging system for 1 hour, then plugging system back into power source, turning it on, and checking time. |
Time-of-day not set - please run SETUP program | Incorrect time or date settings; faulty system battery. | Check the time and date settings. Test CMOS battery by setting time, unplugging system for 1 hour, plugging system back into power source, turning it on, and checking time. |
Timer chip counter 2 failed | Faulty system board. | Try clearing NVRAM, and flashing BIOS and BMC. |
Unsupported CPU combination Unsupported CPU stepping detected |
Microprocessor(s) is not supported by the system. | Try flashing to current BIOS and BMC, or install a supported microprocessor or microprocessor combination. |
Utility partition not available | The <F10> key was pressed during POST, but no utility partition exists on the boot hard drive. | Use the DDDP utility to create a diagnostic CD, USB, Floppy, or image. Or create a utility partition on the boot hard drive. |
Warning! No microcode update loaded for processor <n> | Microcode update failed. | Update the BIOS firmware. |
Warning: Embedded RAID firmware is not present! | Embedded RAID firmware does not respond. | Check seating of RAID controller. Try updating the RAID firmware. |
Warning: Embedded RAID error! | Embedded RAID firmware responds with an error. | Check seating of RAID controller. Try updating the RAID firmware. |
Warning: The current memory configuration is not optimal. Dell recommends a population of 2, 4, 8, or 12 DIMMs. DIMMs should be populated sequentially starting in slot 1. | System has detected a legal but non-optimal population of DIMMs (for example, 1 DIMM, 6 DIMMs, 4 DIMMs in slots 1, 2, 5, and 6, etc.). The system will run with all memory accessible but will experience sub-optimal performance. | Populate 2, 4, 8, or 12 DIMMs sequentially beginning with slot 1. Only the PowerEdge 2900 has 12 DIMMs. |
Write fault Write fault on selected drive |
Faulty diskette, optical/diskette drive assembly, hard drive, or hard-drive subsystem. | Check media on drive. Try known good media on optical and diskette. Do diagnostics on controllers and drives if problem persists. |