PowerEdge 2600 LED Reference Table 1
The following troubleshooting LED codes are valid while the server is not able to complete POST. If the troubleshooting LEDs are on or flashing, refer to the LED definitions and instructions in Table 1.
NOTE: Record and troubleshoot the first LED code in the sequence. This is the most important code to follow when troubleshooting this system. If you were unable to record the first code, completely power off the server and power it back on to record the first LED.
The troubleshooting LEDs also flash codes when the device in question has a hardware fault. LED1 LED2 LED3 LED4 LED5 Problem Off Off Off Off Off AC power not present or bad +3.3V_AUX or PDB not connected Blink Off Off Off On Control Panel Cable Not Present Blink Off Off On Off Back Plane Cable Not Present Blink Off Off On On VRM1 missing Blink Off On Off Off CPU1 missing Blink Off On Off On CPU2 present but VRM2 missing Blink Off On On Off VRM2 present but CPU2 missing Blink Off On On On VRM1 & VRM2 vendors mismatch Blink On Off Off Off CPU1 & CPU2 core voltage (VID) mismatch Blink On Off Off On CPU1 & CPU2 bus frequency mismatch Blink On Off On Off Blink On Off On On CPU1 heat sink not installed properly - Thermtrip on CPU1 Blink On On Off Off CPU2 heat sink not installed properly - Thermtrip on CPU2 Off Blink Off Off On PS_ON# from the ICH3 not happening Off Blink Off On Off +12V bad or missing - power supply not turning ON Off Blink Off On On +1.2V is not good Off Blink On Off Off +1.8V is not good Off Blink On Off On +1.25V is not good Off Blink On On Off +2.5V is not good Off Blink On On On +3.3V is not good On Blink Off Off Off +3.3V_PCI is not good On Blink Off Off On +5V is not good On Blink Off On Off System power good missing - bad U6009 On Blink Off On On Standby power good missing - bad +5V_AUX or +1.8V_AUX On Blink On Off Off CPU1 VRM is not good On Blink On Off On VRM2 VRM is not good Off Off Blink Off On CPU POR is not high - North bridge is not happy Off Off Blink On On ICH3 PCI Reset is not high - ICH3 is not happyNOTE:
Table 1 - PowerEdge 2600 LED Codes
ID do artigo: SLN68953
Data da última modificação: 11/13/2010 12:00 AM
Agradecemos o feedback.