VRTX - 12Gbs SAS Drives and 12th Generation Servers


Note: How to identify the server generation is explained in this article.

For the 13th generation of servers, 12Gb/s SAS Drives were released.

The 12Gb/s SAS drives are supported and validated for use in the VRTX Shared Storage infrastructure to be mapped to 12th and 13th generation blades.

On the 12th generation of servers, the speed of these drives will be reduced to 6Gbs speeds. There is no reduction on 13th generation of servers.

In order to use 12Gbs SAS Drives in the Shared Storage infrastructure (VRTX) , the Back Plane Expander must be updated to Firmware 2.00 or later.



Backplane Expander Installation Instructions


Expander Firmware update is performed by Chassis Management controller for PowerEdge VRTX.

To update the storage components in Chassis Management Controller :

1. In the left pane of Chassis Management Controller, click Chassis Overview. Then click Storage. Then click Update.
2.On the Storage Component Update page, click Browse, select the DUP that is downloaded earlier, and then click Upload.

The DUP is uploaded to CMC and the Firmware Update Status page is displayed with the following information:

Elapsed Time
Target Components
Current Firmware Version
Update State

Power cycle the system is required for this firmware to take effect.

Need more help?
Find additional PowerEdge and PowerVault articles

Visit and ask for support in our Communities

Create an online support Request


Quick Tips content is self-published by the Dell Support Professionals who resolve issues daily. In order to achieve a speedy publication, Quick Tips may represent only partial solutions or work-arounds that are still in development or pending further proof of successfully resolving an issue. As such Quick Tips have not been reviewed, validated or approved by Dell and should be used with appropriate caution. Dell shall not be liable for any loss, including but not limited to loss of data, loss of profit or loss of revenue, which customers may incur by following any procedure or advice set out in the Quick Tips.

Код статьи: SLN298522

Дата последнего изменения: 09/20/2016 09:53 AM


Оцените эту статью

Точно
Функционально
Просто понять
Помогла ли вам эта статья?
Да Нет
Отправьте нам свое мнение
Комментарии не должны содержать следующие специальные символы: <>()\
К сожалению, наша система обратной связи в настоящее время не работает. Повторите попытку позже.

Благодарим вас за отзыв.