LSI Logic PERC 4/SC, PERC 4/DC, v.352D, A22
Dell PowerEdge Expandable RAID Controller 4/DC and 4/SC Firmware Update
Version: 352D
| Release Date: | 7/18/2007 |
| Importance: | Urgent |
| Version: | 352D,A22 See Previous Versions |
The following formats are available for the file you have selected
| File Format: | Floppy |
|
| File Name: |
BR151923.exe |
|
| Description: | This file contains a compressed (or zipped) set of files. Download the file to a folder on your hard drive, and then run (double-click) it to unzip the set of files. Follow the instructions to create a set of floppy diskettes, and then use the diskettes to complete the installation. | |
| Download Type: | HTTP | |
| File Size: | 1MB | |
| File Format: | GnuPG Signature for Linux Update Package |
|
| File Name: |
RAID_FRMW_LX_R151923.BIN.sign |
|
| Description: | The GnuPG signature for Red Hat® Linux Update Package can be used to authenticate the identity of Dell™ in the correlated Red Hat Linux Update Package. You can download the Dell Linux public GnuPG key by navigating to Dell | Linux Web Sites. See the Dell Update Package User's Guide for more information. | |
| Download Type: | HTTP | |
| File Size: | 0.2KB | |
| File Format: | Rel-Notes-Text |
|
| File Name: |
perc4-FWP4352D-A22.txt |
|
| Description: | This file format contains plain text which can be viewed with a standard text editor. | |
| Download Type: | HTTP | |
| File Size: | 14KB | |
| File Format: | Update Package for Microsoft® Windows® |
|
| File Name: |
RAID_FRMW_WIN_R151923.EXE |
|
| Description: | Update Packages for Windows can be used as a stand-alone application to apply an update and ensure that specific validation criteria are met before performing the update. See the Dell Update Package User's Guide for more information. Note: As of October 10th, 2005, Update Packages for Windows will be digitally signed. Customers using Dell OpenManage™ IT Assistant to deploy updates must upgrade to version 7.1 or later. |
|
| Download Type: | HTTP | |
| File Size: | 5MB | |
| File Format: | Update Package for Red Hat Linux |
|
| File Name: |
RAID_FRMW_LX_R151923.BIN |
|
| Description: | Dell Update Packages for Linux can be used as a stand-alone application to apply an update and ensure that specific validation criteria are met before performing the update. See the Dell Update Packages for Linux Operating Systems User's Guide for more information. Note: Update Packages for Linux contain open source. See the Dell Update Packages Readme for Linux for details. |
|
| Download Type: | HTTP | |
| File Size: | 10MB | |
Previous Versions
|
1.03, A02
<ul><li><b>Vendor Version :</b> 1.03</li><li><b>Dell Version :</b> A02</li></ul>
|
6/7/2005 6:45:12 PM |
|
6.46.2.32, A05
<ul><li><b>Vendor Version :</b> 6.46.2.32</li><li><b>Dell Version :</b> A05</li></ul>
|
6/7/2005 3:27:26 PM |
|
6.41.2.32, A04
<ul><li><b>Vendor Version :</b> 6.41.2.32</li><li><b>Dell Version :</b> A04</li></ul>
|
9/16/2004 5:23:42 PM |
|
6.41.2.32, A03
<ul><li><b>Vendor Version :</b> 6.41.2.32</li><li><b>Dell Version :</b> A03</li></ul>
|
2/23/2004 5:52:05 PM |
|
6.35.2.32, A02
<ul><li><b>Vendor Version :</b> 6.35.2.32</li><li><b>Dell Version :</b> A02</li></ul>
|
8/28/2003 4:51:56 PM |
|
3.18, A01
<ul><li><b>Vendor Version :</b> 3.18</li><li><b>Dell Version :</b> A01</li></ul>
|
5/27/2003 4:40:28 PM |
|
6.32.2.32, A01
<ul><li><b>Vendor Version :</b> 6.32.2.32</li><li><b>Dell Version :</b> A01</li></ul>
|
5/23/2003 8:17:39 PM |
Description
Dell PowerEdge Expandable RAID Controller 4/DC and 4/SC Firmware Update
Version: 352D
Level of Importance:Urgent
Dell highly recommends applying this update as soon as possible. The update contains changes to improve the reliability and availability of your Dell system.
Important Information
1. After installing this firmware and rebooting, a consistency check will automatically begin on
RAID 5 and 50 virtual disks with 5 or more physical disks to ensure parity information is
correct. The consistency check cannot be terminated and will resume at its last point
following a reboot. This consistency check will appear as a Background Initialization but
will only perform a consistency check with no data being modified. The consistency check runs
in the background, allowing the virtual disks to remain accessible during the check. While
this background check is designed to minimize performance impact, some degradation in
performance may occur until the check is complete, especially under heavy I/O.
Compatibility
| Systems Enterprise Servers 1800 Enterprise Servers 1850 Enterprise Servers 2800 Enterprise Servers 2850 Enterprise Servers 6800 Enterprise Servers 6850 Enterprise Servers 850 PowerEdge 1400 / 1400SC PowerEdge 1400 / 1400SC PowerEdge 1500SC PowerEdge 1600SC PowerEdge 1650 PowerEdge 1750 PowerEdge 1850 PowerEdge 2500 / 2500SC PowerEdge 2500 / 2500SC PowerEdge 2550 PowerEdge 2600 PowerEdge 2650 PowerEdge 2850 PowerEdge 4400 PowerEdge 4600 PowerEdge 500SC PowerEdge 600SC PowerEdge 6400 PowerEdge 6450 PowerEdge 650 PowerEdge 6600 PowerEdge 6650 PowerEdge 700 PowerEdge 750 PowerEdge 800 PowerEdge 830 PowerEdge 8450 PowerEdge PE2800 PowerVault 745N PowerVault 770N PowerVault 775N | Operating Systems Not Applicable |
Applies to
- PERC 4/DC
- PERC 4/SC
Fixes & Enhancements
Fixes:
1. Addresses a problem that may occur if a drive fails with in seconds after another drive completes a rebuild.
2. Fixed issue on PERC Controllers where VMFS Volumes go missing in VMware ESX environments after updating firmware from version 351X and earlier to 352B
Note: Updating to (352D from a system that was installed onto 352B) will require customers to resignature the volumes in order to have VMware to recognize the volumes.
Affected upgrade scenarios:
a. Upgrade from 351X to 352B
b. Upgrade from 352B to 352D
c. Upgrade from 351X to 352B then to 352D
Unaffected upgrade scenarios:
a. Upgrade from 351X and earlier to 352D
Installation Instructions
Custom Instructions for BR151923.exe:
This program creates a bootable diskette to upgrade the firmware of the
controllers. You will need a formatted 3 1/2 inch floppy diskette for the
following procedure.
1) Download the file to a directory on your hard drive. The file downloaded is
a self extracting executable.
2) Insert a blank diskette into the system's diskette drive.
3) Double click on the file that you downloaded and follow the instructions on
the screen to extract the files to the diskette.
4) Insert the diskette into the system with the RAID controller for which you
want to update the firmware and boot the system.
5) Follow the instructions on the screen to update the firmware.
NOTICE: Pflash.exe will be executed automatically and will report existing code
level and prompt you to reconfirm before starting the firmware upgrade
process.
To perform this process in non-interactive mode please execute,
Pflash /?
and read about possible command line switches.
6) Remove the diskette and reboot the system.
Custom Instructions for perc4-FWP4352D-A22.txt:
Download the readme file to view information about this release.
Instructions for RAID_FRMW_LX_R151923.BIN:
Download
1. Click the Download Now link to download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.
Installation
1. Read over the release information presented by executing the ./RAID_FRMW_LX_R151923.BIN --version command from the shell.
2. Download and install any prerequisites identified in the above step before proceeding.
3. Run the update by executing ./RAID_FRMW_LX_R151923.BIN from the shell.
4. Follow the remaining prompts to perform the update.
GnuPG Signature of Dell Update Package Instructions for RAID_FRMW_LX_R151923.BIN.sign:
Download
1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to your hard drive.
Installation
1. Import the Dell public key. (You only need to do once on your system.)
2. Verify the Dell Update Package by using its signature file, RAID_FRMW_LX_R151923.BIN.sign
Instructions for RAID_FRMW_WIN_R151923.EXE:
Download
1. Click the Download Now link to download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.
Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.
Checksum
To ensure the integrity of your download, please verify the checksum value.
This is an optional process and is not required for the downloading and installation of device drivers from this site.
This is an optional process and is not required for the downloading and installation of device drivers from this site.
|
MD5:
SHA1:
|
C80B13D89FEC51D92D8A2FFC9896786B
Not Available
|
RAID_FRMW_WIN_R151923.EXE
RAID_FRMW_WIN_R151923.EXE
|
My Download List
0
files in my list
Drivers Quick Links