Dell PERC 6/i Adapter, v.6.3.1-0003, A14
Dell PERC6/I Adapter firmware release version 6.3.1-0003
| Release Date: | 11/1/2011 |
| Importance: | Recommended |
| Version: | 6.3.1-0003,A14 See Previous Versions |
The following formats are available for the file you have selected
| File Format: | GnuPG Signature for Linux Update Package |
|
| File Name: |
SAS-RAID_Firmware_392W6_LN32_6.3.1-0003_A14.BIN.sign |
|
| Description: | The GnuPG signature for Red Hat® Linux Update Package can be used to authenticate the identity of Dell™ in the correlated Red Hat Linux Update Package. You can download the Dell Linux public GnuPG key by navigating to Dell | Linux Web Sites. See the Dell Update Package User's Guide for more information. | |
| Download Type: | HTTP | |
| File Size: | 0.2KB | |
| File Format: | Hard-Drive |
|
| File Name: |
DELL_PERC-6-I-ADAPTER_A14_R313334.exe |
|
| Description: | This file contains a compressed (or zipped) set of files. Download the file to a folder on your hard drive, and then run (double-click) it to unzip the set of files. Follow the instructions to complete the installation. | |
| Download Type: | HTTP | |
| File Size: | 1MB | |
| File Format: | Rel-Notes-Text |
|
| File Name: |
R313334.txt |
|
| Description: | This file format contains plain text which can be viewed with a standard text editor. | |
| Download Type: | HTTP | |
| File Size: | 15KB | |
| File Format: | Update Package for Microsoft® Windows® |
|
| File Name: |
SAS-RAID_Firmware_392W6_WN32_6.3.1-0003_A14.EXE |
|
| Description: | Update Packages for Windows can be used as a stand-alone application to apply an update and ensure that specific validation criteria are met before performing the update. See the Dell Update Package User's Guide for more information. Note: As of October 10th, 2005, Update Packages for Windows will be digitally signed. Customers using Dell OpenManage™ IT Assistant to deploy updates must upgrade to version 7.1 or later. |
|
| Download Type: | HTTP | |
| File Size: | 6MB | |
| File Format: | Update Package for Red Hat Linux |
|
| File Name: |
SAS-RAID_Firmware_392W6_LN32_6.3.1-0003_A14.BIN |
|
| Description: | Dell Update Packages for Linux can be used as a stand-alone application to apply an update and ensure that specific validation criteria are met before performing the update. See the Dell Update Packages for Linux Operating Systems User's Guide for more information. Note: Update Packages for Linux contain open source. See the Dell Update Packages Readme for Linux for details. |
|
| Download Type: | HTTP | |
| File Size: | 4MB | |
Previous Versions
|
00.00.04.31.2-1, A12
<ul><li><b>Vendor Version :</b> 00.00.04.31.2-1</li><li><b>Dell Version :</b> A12</li></ul>
|
12/1/2010 10:09:46 AM |
|
00.00.04.29-1, A11
<ul><li><b>Vendor Version :</b> 00.00.04.29-1</li><li><b>Dell Version :</b> A11</li></ul>
|
7/7/2010 10:17:26 AM |
Description
Dell PERC6/I Adapter firmware release version 6.3.1-0003
Level of Importance:Recommended
Dell recommends applying this update during your next scheduled update cycle. The update contains feature enhancements or changes that will help keep your system software current and compatible with other system modules (firmware, BIOS, drivers and software).
Important Information
1. When viewing SATA physical disk properties from Ctrl-R or other management applications, the Vendor Identification will be translated as "ATA" followed by blanks.
2. If all physical disks making up a virtual disk are removed from the system or enclosure, the RAID controller will delete the virtual disk. If the disks are later re-inserted, they will be marked foreign and can be imported using a management application.
3. If a virtual disk is configured with write-back cache enabled and some or all of its physical disks are removed from the system or enclosure, the RAID controller will preserve the virtual disk's write cache. The controller will flush the preserved cache when the physical disks are replaced and the foreign configuration is imported. Any attempt to update controller firmware will be blocked when cache is preserved for a virtual disk.
4. Physical disks determined to contain a foreign configuration are not available for configuration as a new dedicated or global hot spare, or as a member of a new virtual disk. The foreign configuration must be imported or cleared from the physical disk before it may be used as a hot spare or member of a virtual disk. Physical disks with a foreign configuration will not appear on the Create New VD screen in Ctrl-R.
5. Prior to performing a virtual disk migration to another system, the source system must be powered off before removal of the physical disks to preserve the correct virtual disk state. This is not required for the target system and the physical disks may be inserted while the system is powered on or off.
6. The controller restricts the importing of virtual disks that are undergoing RAID Level Migration or Capacity Expansion. Do not interrupt virtual disks that are performing either of these operations because it will disable the ability to import the virtual disk and the data will be unavailable. Dell recommends that the user perform a data backup before starting these operations.
7. EMM changes or drive migrations are not supported during a Capacity Expansion or Raid Level Migration. This may cause the VDs to go offline. Dell recommends the user to perform a data backup before starting these operations.
8. This version of firmware will not ensure complete compatibility with an older version of management applications. OpenManage 5.5 or greater is recommended.
9. It is recommended that the customer upgrade the management application and device driver to the latest version available from Dell at the time of installation of this firmware.
10. Important Information for Update Packages for Microsoft Windows
a. Do not run other applications while executing Dell Update Packages.
b. Do not run storage controller update packages if the controller is in use
by other applications. The firmware upgrade may fail if any of the
RAID controllers in the system are performing I/O background tasks
(consistency checks, background initializations, rebuilds, or
reconstructions). Allow the background tasks to complete before
attempting to upgrade the firmware. Patrol Read tasks will not affect
firmware upgrades.
11. Important Information for Update Packages for Linux
a. Do not run other applications while executing Dell Update Packages.
b. If the following error occurs, "Error while loading shared libraries:
libstdc++.so.5: cannot open shared object file: No such file or
directory", you must install the compatibility libraries. These
libraries can be found on the installation media or online. To install
the compatibility libraries, use the following commands:
"rpm -ih compat-libstdc++-33-3.2.3.-*.i386.rpm" for RHEL 4 or 5
"rpm -ih compat-libstdc++-5.0.7-*.x86_64.rpm" for SLES 10
c. When Update Packages stop abruptly due to a power outage or abnormal
termination, perform the following steps:
- Remove the lock file.
- Type the following command: rm -f /var/lock/.spsetup
- Run the Update Package again to reapply the update.
d. Do not ru
Compatibility
| Systems Cloud Products C1100 Enterprise Servers R310 Enterprise Servers R410 Enterprise Servers R905 Enterprise Servers R910 Enterprise Servers T300 Enterprise Servers T310 Enterprise Servers T410 Enterprise Servers T605 PowerEdge 840 Powervault DL2200 PowerVault DP100/NF100 PowerVault NX300 Precision R5500 Precision R5500 | Operating Systems Not Applicable |
Applies to
- PERC 6/i Adapter
- DOC,USER,SAS,PERC6/I,ENG
- DOC,USER,SAS,PERC6/I,GER
- DOC,USER,SAS,PERC6/I,SPN
- DOC,USER,SAS,PERC6/I,KOR
- DOC,USER,SAS,PERC6/I,TCHI
- DOC,USER,SAS,PERC6/I,FR
- DOC,USER,SAS,PERC6/I,RUS
- DOC,USER,SAS,PERC6/I,SCHI
- DOC,USER,SAS,PERC6/I,JPN
- PERC 5/i Adapter
Fixes & Enhancements
1. Fixes an issue where the Perc battery does not always charge up properly, causing Virtual Disks changing from Write Back to Write Through.
2. Removes system events that relate to partial Patrol completion on physical drives.
Checksum
To ensure the integrity of your download, please verify the checksum value.
This is an optional process and is not required for the downloading and installation of device drivers from this site.
This is an optional process and is not required for the downloading and installation of device drivers from this site.
|
MD5:
|
b157de99a0f8acbc2436da9a878ad7f8
|
SAS-RAID_Firmware_392W6_LN32_6.3.1-0003_A14.BIN.sign
|
|
SHA1:
|
0af0351f951bfdac5f080d2d1d72ebb4b086e9f2
|
SAS-RAID_Firmware_392W6_LN32_6.3.1-0003_A14.BIN.sign
|
|
SHA-256:
|
Not Available
|
SAS-RAID_Firmware_392W6_LN32_6.3.1-0003_A14.BIN.sign
|
My Download List
0
files in my list
Drivers Quick Links