Dell PowerEdge PEC8000 FCB firmware
Dell PowerEdge PEC8000 FCB firmware
| Release Date: | 2/6/2013 |
| Importance: | Recommended |
| Version: | 2.07 |
The following formats are available for the file you have selected
| File Format: | Floppy |
|
| File Name: |
Zeus_FCB_Software.02.07.exe |
|
| Description: | This file contains a compressed (or zipped) set of files. Download the file to a folder on your hard drive, and then run (double-click) it to unzip the set of files. Follow the instructions to create a set of floppy diskettes, and then use the diskettes to complete the installation. | |
| Download Type: | HTTP | |
| File Size: | 1MB | |
| File Format: | Plain-Text |
|
| File Name: |
EndUser LicenseAgreementType S_Rev. 040512.txt |
|
| Description: | This file format contains plain text which can be viewed with a standard text editor. | |
| Download Type: | HTTP | |
| File Size: | 11KB | |
Previous Versions
No previous version available.
Description
Dell PowerEdge PEC8000 FCB firmware
Level of Importance:Recommended
Dell recommends applying this update during your next scheduled update cycle. The update contains feature enhancements or changes that will help keep your system software current and compatible with other system modules (firmware, BIOS, drivers and software).
Compatibility
| Systems Cloud Products C8000 | Operating Systems Not Applicable |
Applies to
- Power Edge C8000
Fixes & Enhancements
1. Over later BMC V1.27 can compatible FCB V2.07
2. Fix BITS049573 [FC] FC didn't show correct update value via Mib browser
3. Fix BITS049630 [FC] SNMP psuConfiguration should include 1+1, 2+0 ,2+1, 3+1, 22, 4+0 , current is 4+2,5+1 .
4. Fix BITS051066 [FC] Sometimes PSU presence detect deasserted and asserted when plug out PSU power cord
5. Add inlet temperature debounce, when FCB reads inlet temperature is larger than 10 degree c compared with previous reading, it will print debug message, drop reading, re-initialize AT73C508 and re-read gain. When debug console command set inlet_tmp 0, it will also re-initialize AT73C508 again.
6. Remove ODM string in FW update utility
Installation Instructions
1. IPMI Driver or OpenIPMI Driver should be enabled in Linux and
Windows.
2. Run with Batch file.
Dos:
execute dos.bat to update FCB.
Linux:
execute linux.sh to update FCB.
Windows:
execute win.bat to update FCB.
Checksum
To ensure the integrity of your download, please verify the checksum value.
This is an optional process and is not required for the downloading and installation of device drivers from this site.
This is an optional process and is not required for the downloading and installation of device drivers from this site.
|
MD5:
|
e68b656adbab5c7f796e323806bc1cbc
|
Zeus_FCB_Software.02.07.exe
|
|
SHA1:
|
a7d89208d5ac567ce0b4fe96cbbb829d659c3ea3
|
Zeus_FCB_Software.02.07.exe
|
|
SHA-256:
|
fd72596acafc0a7e2c01049d8f80e45eaa2bcc6e6fd78fdc1cc44a159c6454e7
|
Zeus_FCB_Software.02.07.exe
|