VMware vCenter Plug-in for MD-Series Storage Arrays, version 2.5
VMware vCenter Plug-in for MD-Series Storage Arrays, version 2.5
| Release Date: | 12/6/2012 |
| Importance: | Recommended |
| Version: | A00 See Previous Versions |
The following formats are available for the file you have selected
| File Format: | Application |
|
| File Name: |
vCenter25_Installer-02.50.3600.0020.zip |
|
| Description: | Application | |
| Download Type: | HTTP | |
| File Size: | 167MB | |
| File Format: | Rel-Notes-Text |
|
| File Name: |
v2.5_vCenter_readme.txt |
|
| Description: | This file format contains plain text which can be viewed with a standard text editor. | |
| Download Type: | HTTP | |
| File Size: | 9KB | |
Previous Versions
|
, A08
<ul><li><b>Dell Version :</b> A08</li></ul>
|
10/23/2012 6:23:37 PM |
|
NA, A07
<ul><li><b>Vendor Version :</b> NA</li><li><b>Dell Version :</b> A07</li></ul>
|
9/25/2012 3:32:58 PM |
|
, A06
<ul><li><b>Dell Version :</b> A06</li></ul>
|
7/25/2012 2:47:46 PM |
|
2.4, A00
<ul><li><b>Vendor Version :</b> 2.4</li><li><b>Dell Version :</b> A00</li></ul>
|
3/27/2012 10:21:35 PM |
Description
VMware vCenter Plug-in for MD-Series Storage Arrays, version 2.5
Level of Importance:Recommended
Dell recommends applying this update during your next scheduled update cycle. The update contains feature enhancements or changes that will help keep your system software current and compatible with other system modules (firmware, BIOS, drivers and software).
Important Information
Save Configuration Files Option Fails on Storage Arrays Running RAID Controller Firmware Version 7.35
ISSUE:
The Save Configuration Files option in the MD vCenter Plug-in fails to execute on storage arrays running RAID controller firmware version 7.35 and generates a validation error. The cause of this error is due to the presence of the 'securityType=' syntax on the command line argument. This syntax is not supported with this firmware version.
Script file example:
show "Creating RAID 0 Volume 1 on new Volume Group BW-Test2084.";
// This command creates volume group <BW-Test2084> and the initial volume <1> with offset 0 on the volume group.
// NOTE: For Volume Groups that use all available capacity, the last Volume on this group is
// created using all remaining capacity by omitting the capacity= volume creation parameter.
create volume drives=(85,1) raidLevel=0 userLabel="1" volumeGroupUserLabel="BW-Test2084" 8240 Bytes dssPreAllocate=false securityType=none;
WORKAROUND:
Storage arrays running RAID controller firmware version 7.35 should remove the 'securityType=' syntax from all Create Volume commands before validating or executing the script file from the MD Storage Manager (MDSM) Enterprise Management Window (EMW).
PROCEDURE:
1. Edit the script file to be used (for example, Array-1_20120122151509705.cfg).
2. Search the script file for the presence of the 'securityType=' command syntax.
3. Remove all occurrences of the 'securityType=' syntax.
4. Save the script file with a new name (preserve original).
5. From the MDSM Enterprise Management Window, right-click on the storage array to be configured and select Execute Script.
6. From the Script Editor, select File > Load Script and select the configuration file you saved in step 4. (You may have to change the file type drop-down option to All Files instead of Script File (*.script)).
7. Select Tools > Verify Syntax to verify the script is functional.
8. Select Tools > Verify and Execute to apply the script changes to the selected storage array.
Compatibility
| Systems Powervault MD3200 Powervault MD3200i Powervault MD3220 Powervault MD3220i Powervault MD3260 Powervault MD3260I Powervault MD3600F Powervault MD3600i Powervault MD3620F Powervault MD3620i Powervault MD3660F Powervault MD3660I | Operating Systems VMWare ESXi 4.1 VMWare ESXi 5.0 MS Windows 2008 x64 MS Windows Server 2012 MS Windows Server 2003 MS Windows 2008 R2 MS Windows 2003 x64 VMWare ESX 4.1 VMWare ESXi 5.1 |
Applies to
- MD Storage Array vCenter Plug-in
Fixes & Enhancements
vCenter Plug-in Release 2.5 adds support for setting up asynchronous remote replication, using point-in-time (PiT) snapshots and performing enhanced automatic storage array discovery.
Installation Instructions
To install the MD vCenter Plug-in:
1. From the Drivers and Download page at www.support.dell.com, select your MD storage array model.
2. From the list of available downloads, choose vCenter Version 2.5 Plug-In from the Applications category.
3. Download the executable file to your system.
4. Launch the vCenter Plug-in installation wizard contained in the downloaded package.
5. Review and accept the license agreement, then follow the installation prompts.
6. Once the installation is complete, refer to the Dell PowerVault MD-Series Storage Array VMware vCenter Plug-In for MD-Series Storage Arrays Installation and Configuration Guide at support.dell.com/manuals for setup and configuration steps
To upgrade from a previous version of the MD vCenter Plug-in and use the same host server as the application server, run the latest installer on the current application server. The installation wizard will prompt for an administrator password before unregistering and upgrading your MD vCenter Plug-in version.
Checksum
To ensure the integrity of your download, please verify the checksum value.
This is an optional process and is not required for the downloading and installation of device drivers from this site.
This is an optional process and is not required for the downloading and installation of device drivers from this site.
|
MD5:
SHA1:
|
4e9e13d4c82c48cd2bdbc0f290fa0d87
a0982b243ec74e0488f1644d8244d08b78f790a7
|
vCenter25_Installer-02.50.3600.0020.zip
vCenter25_Installer-02.50.3600.0020.zip
|
My Download List
0
files in my list
Drivers Quick Links