Dell PowerVault 220S/221S SES Firmware, v.E.17, A06

AUTO INSTALLED This file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
The PV22xS_E17.bin file is the downloadable version of the enclosure firmware that provides management functions for the PowerVault 220S/221S. These functions include SCSI Enclosure Services (SES) and SCSI Accessed Fault-Tolerant Enclosures (SAF-TE) reporting to the host initiator, control of all enclosure LED indicators, and monitoring of all the enclosure's environmental elements.
Recommended

Find the best download for your system

Please enter your product details to view the latest driver information for your system

Search support

Enter your Dell Service Tag or model

Want to look up your product? Enter a product identifier. Show me how

This driver is not compatible

This driver is not applicable for the selected product. Choose another product to re-enter your product details for this driver or visit the Product Support page to view all drivers for a different product.

Find more updates. Use SupportAssist to find all the latest driver updates for your device.

Fixes & Enhancements

Firmware E.17 is strictly a maintenance release for PV220S/PV221S. Dell recommends that all PV220S/PV221S be at minimal level of E.16 or greater. Systems having E.16 is not required to upgrade to E.17, which provides the following updates: Removed reading of fans and power supply FRU part numbers to fix manufacturing test issues. FRU (Field Replaceable Units) are also referred to as service part numbers. No impact to customers since service calls always cross reference to the latest available service part number. Add retry operations to read FRUs if it failed to read previously during enclosure initialization.
Read More

Version

E.17, A06

Release date

26 Aug 2005

Download Type

Firmware

Category

DAS

Importance

Recommended
Dell Technologies recommends applying this update during your next scheduled update cycle. The update contains changes to maintain overall system health. It ensures that the system software remains current and compatible with other system modules (firmware, BIOS, drivers, and software) and may include other new features.
Available formats View Important Information

File Format: Update Package for MS Windows 32-Bit
File Name: FRMW-R74083.exe
File Size: 2.24 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages (DUP) in Microsoft Windows 32bit format have been designed to run on Microsoft Windows 64bit Operating Systems. Dell Update Packages (DUP) in Microsoft Windows 64bit format will only run on Microsoft Windows 64bit Operating Systems. When selecting a device driver update be sure to select the one that is appropriate for your operating system.
To ensure the integrity of your download, please verify the checksum value.
MD5:
B898B9D875B654604EEF9C8BE09DB053
SHA1:
Not available
SHA-256:
Not available

File Format: Extracts files directly to local disk
File Name: FUPG_E17.exe
File Size: 48.54 KB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
This file format consists of an archive of files that may be decompressed to a directory on the hard drive. The installation can then be done from that directory.
To ensure the integrity of your download, please verify the checksum value.
MD5:
Not available
SHA1:
Not available
SHA-256:
Not available

File Format: Update Package for Red Hat Linux
File Name: FRMW-R74083.bin
File Size: 2.01 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages for Linux can be used as stand-alone applications that ensure that specific validation criteria are met, then apply an update.
Note: Update Packages for Linux are open source. See the Dell Update Packages for Linux Readme for details.
To ensure the integrity of your download, please verify the checksum value.
MD5:
B783C566741E5AD223AE1F4008B217AD
SHA1:
Not available
SHA-256:
Not available

By downloading, you accept the terms of the Dell Software License Agreement.

Additional details

Show All | Hide All
Known Limitations:
  1. In Joined bus/Clustering mode, firmware is downloaded to both EMMs automatically (assuming that the second EMM is installed) by failing over and then failing back. In Split bus mode, however, updating firmware on one EMM does not automatically update the other EMM. Therefore, in order to update both EMMs, the user must download directly through the cable to each EMM.

  2. When using Array Manager 3.1.1 (or less) in Clustering mode, EMM firmware can only be upgraded on the primary EMM (the left one when viewing the enclosure from the back). Therefore, in order to update both EMMs, the user must download firmware to each EMM individually.

  3. If the PV22XS is configured with one EMM and one termination module in Joined bus mode, an error message will pop up when upgrading the firmware through Array Manager 3.1.1 (or less). This is an invalid error message in this scenario. If the fans have gone back to normal speed, then the firmware download was successful. To verify this, stop and restart the Disk Management Service. Then you can view the firmware version under the enclosure properties.

  4. Firmware updates to enclosures attached to PERC 2/DC, PERC3/SC/QC/DC/DCL, or any PERC4 array controllers require that Array Manager be at release 3.4 or greater; while PERC 2/QC or PERC 3/Di controllers require that Array Manager be at least 3.5 or greater.

Custom Instructions for FUPG_E17.exe:

Updating Firmware Using Array Manager
(Windows & NetWare)


Dell OpenManage Array Manager software provides a comprehensive storage management solution that enables you to configure and manage local and remote storage attached to a system. Array Manager includes an integrated firmware update utility that can be used with the following operating ystems:

  • Windows 2000 Server and Advanced Server

  • Windows Server 2003

  • Novell NetWare (all Dell-supported versions)


To update the firmware on your PowerVault 22xS storage system using Array Manager:

NOTE: In the following steps, xx refers to the firmware release number.

  1. Stop all I/O activity to the storage system.

  2. Create a directory on your local file system.

  3. Download the FUPG_E.xx.EXE file to a directory on your hard drive. The file downloaded is a self-extracting executable. step 2.

  4. Double-click the FUPG_Exx.exe file to extract the firmware update files to your system's hard drive.

  5. On the host system, click the Start button and select Programs > Dell OpenManage Applications
    > Array Manager > Array Manager Console.

  6. Select Arrays > PERC Subsystem.

  7. Select the controller that is linked to the enclosure you are upgrading.

  8. Right-click the enclosure object and select Download Firmware.

  9. Navigate to the .bin file that was extracted in step 4.

  10. Double-click the .bin file and follow the directions on your screen. When the update is complete, a message appears indicating that the update was successful.

    Note: The firmware update may take up to 5 minutes to complete depending on the server speed. Please allow the appropriate time for the firmware update to complete.

  11. Restart I/O activity to the storage system.



Custom Instructions for FRMW-R74083.exe:

Windows Dell Update Packages Procedure


Dell Update Packages (DUPs) are software utilities provided by Dell to update specific software components on your Dell system. DUPs provide an easy-to-use graphical user interface (GUI) that enables you to apply a software update to either a single system or, remotely, to multiple systems using your organization’s software distribution tools. DUPs run separately from Array Manager, so you can use a DUP if Array Manager is not available on your host system. Dell provides DUPs for the following operating systems:


  • Windows 2000 Server and Advanced Server

  • Windows Server 2003

  • Red Hat Enterprise Linux (Version 2.1)

  • Red Hat Enterprise Linux (Version 3) for Intel x86


Windows DUP Update Procedure

The following procedure updates the firmware on a PowerVault 22xS storage system that is attached to a host system that is running the 32-bit version of Windows 2000 Server, Advanced Server, or Windows Server 2003, without Array Manager.
  1. Stop all I/O activity to the storage system.

  2. Create a directory on your local file system.

  3. Download the executable Windows DUP package file (PV220s-221s-FRMW-Rxxxxx.exe, where Rxxxxx indicates the release) from the Dell Support website at support.dell.com and save the file to the directory you created in step 2.

  4. Double-click the downloaded file to uncompress the file and start the update.

  5. When prompted, click Install to update the firmware. When the update is complete, a message appears indicating that the update was successful.

  6. Restart I/O activity to the storage system.


Custom Instructions for FRMW-R74083.bin:

Linux Dell Update Packages


Drivers help and tutorials