Dell SAS 6/iR Adapter, v.00.25.47.00.06.22.03.00 , A04

需要重新启动 已自动安装 此文件是作为最近更新的一部分自动安装的。如果您遇到任何问题,您可以手动下载并重新安装。
此页面的内容可能已自动翻译。要提供反馈,请填写页面底部的表单。
Dell Sas6/iR Adapter Firmware Release; Package Version: 00.25.47.00.06.22.03.00
推荐

查找适合您的系统的最佳下载内容

请输入您的产品详细信息以查看系统的最新驱动程序信息

搜索支持

输入您的戴尔服务编号或型号

想要查找您的产品吗?请输入产品标识符。 演示操作

此驱动程序不兼容

此驱动程序不适用于所选产品。选择另一个产品以重新输入此驱动程序的产品详细信息,或访问产品支持页面以查看其他产品的所有驱动程序。

查找更多更新。使用 SupportAssist 查找适用于您的设备的所有最新驱动程序更新。

补丁和增强功能

BIOS - 06.22.03.00
NEW FUNCTIONALITY: None.
DEFECT FIXES:
-Implements a change to allow some RAID1 volumes created with earlier
SAS 6/iR FW revisions to be migrated to controllers with this FW revision.
- Implements a change to order the controller list based on defined
controller type instead of static chip-based references
- Updates verify functionality to allow user to escape once
Reassign All has been selected and drive is no longer responding.
- Removes rescan for devices on any keystroke in view array screen.
Rescan will now only be performed on Alt+N keystroke.


FIRMWARE - 00.25.47.00
NEW FUNCTIONALITY:
- Modifies coercion of RAID volumes to align with PERC. This facilitates
migration of SAS6 RAID volumes to PERC6.
DEFECT FIXES:
-Implements a change to allow some RAID1 volumes created with earlier
SAS 6/iR FW Revisions to be migrated controllers with this FW revision or later.
-Improves robustness in handling Task Management events during heavy IO
-Implements a change to correct an issue with initialization of interposer
attached SATA drives where link to the drive could be left in a state where
it was possible that I/Os could be timed out and have to be retried by
the host.
了解详情

版本

00.25.47.00.06.22.03.00, A04

发布日期

06 12月 2011

下载类型

固件

类别

SAS RAID

重要性

推荐
Dell Technologies 建议在下一个计划的更新周期期间应用此更新。更新包含用于维护整体系统运行状况的更改。它可确保系统软件保持最新状态并与其他系统模块(固件、BIOS、驱动程序和软件)兼容,并且可能包括其他新功能。
可用格式 查看重要信息

文件格式: 面向MS Windows(32位)的更新包
文件名: SAS-RAID_Firmware_6T2TK_WN32_00.25.47.00.06.22.03.00_A04.EXE
文件大小: 5.57 MB
这是一个大文件。根据您的连接速度,可能需要一些时间来下载。
格式说明:
Microsoft Windows 32位格式中的戴尔更新包(DUP)设计为可以在Microsoft Windows 64位操作系统上运行。Microsoft Windows 64位格式中的戴尔更新包(DUP)仅可在Microsoft Windows 64位操作系统上运行。选择设备驱动程序更新时,请务必选择适合您的操作系统的更新。
为确保下载的完整性,请验证校验和值。
MD5:
6187d1acd2a29a1b0bd68d9ed4789a7d
SHA1:
5fcdb8dbb89c95962ec355814802c7aa36fdd3f6
SHA-256:
不提供

文件格式: 包含加密签名的GnuPG文件
文件名: SAS-RAID_Firmware_6T2TK_LN32_00.25.47.00.06.22.03.00_A04.BIN.sign
文件大小: 194 Bytes
这是一个大文件。根据您的连接速度,可能需要一些时间来下载。
格式说明:
Red Hat Linux更新包的GnuPG签名可用于验证戴尔在相关Red Hat Linux更新包中的身份。
为确保下载的完整性,请验证校验和值。
MD5:
09d199c003966038a643403451616101
SHA1:
960216fb1a68cf23c8e6b5b895696e31a80e85f2
SHA-256:
不提供

文件格式: 外置ZipPack
文件名: DELL_SAS-6-IR-ADAPTER_A04_R197382.exe
文件大小: 563.47 KB
这是一个大文件。根据您的连接速度,可能需要一些时间来下载。
格式说明:
此文件包含一组压缩文件。将文件下载到硬盘上的文件夹中,然后运行(双击)它来解压这组文件。请按照说明完成安装。
为确保下载的完整性,请验证校验和值。
MD5:
34a3cf38ec1f9c10ecfd2b4ac32a6b9d
SHA1:
2c1fac888775182b63f461c1da1df756b6533619
SHA-256:
b065927408cd8cf1e4afd61593cdc146dced2dda1453f597cb1f7773de8d3c6f

文件格式: 外部版本说明
文件名: R197382.txt
文件大小: 7.23 KB
这是一个大文件。根据您的连接速度,可能需要一些时间来下载。
格式说明:
此文件格式包含纯文本,您可以采用标准文本编辑器进行查看。
为确保下载的完整性,请验证校验和值。
MD5:
4b11813d93d89a8fe4b925773e0581a2
SHA1:
不提供
SHA-256:
不提供

文件格式: Red Hat Linux的更新包
文件名: SAS-RAID_Firmware_6T2TK_LN32_00.25.47.00.06.22.03.00_A04.BIN
文件大小: 3.65 MB
这是一个大文件。根据您的连接速度,可能需要一些时间来下载。
格式说明:
适用于Linux 的戴 尔更新包是在 满足特定的标准系统环境下使用的独立应用程序。,然后应用更新。
注意:Linux的更新包是开源的。查看适用于Linux 的戴 尔更新包自述以了解 详情,了解详情。
为确保下载的完整性,请验证校验和值。
MD5:
4d4ee10cd8f3ae46527f70a38e17169f
SHA1:
4265f3a8b30dd24f83790d919e306d39c1a3a9ae
SHA-256:
不提供

开始下载软件,即表示您接受戴尔软件许可协议 ( 英文版 ) 条款。

- When viewing SATA physical disk properties from Ctrl-C or other
management applications, Vendor Identification must be translated
as "ATA" followed by blanks. Please see SATA translation
specification, revision 5, pages 24-25 for more details.

- When multiple logical disks are configured on the SAS 6/iR and when viewing the logical disks from RAID Properties of the Ctrl-C BIOS utility, the order in which the logical disks are displayed may be reversed from the order in which they are created. This has no effect on the adapter functionality or boot order of the logical disks.

- When adding a SAS 6/iR controller to a system, either by physically
adding an adapter or by enabling the integrated SAS controller in
the system BIOS, the new controller may need to be added to the
controller boot order in the SAS 6/iR BIOS configuration Utility.
At POST, hit CTRL-C to enter the utility and verify or modify the
controller boot order.

- Migration of RAID Volumes from SAS 6/iR controllers to PERC6 controllers
is supported only for volumes originally created on SAS 6/iR controllers
running FW revision 00.25.47.00 or later.

- This version of firmware will not ensure complete compatibility with an
older version of the management application.
OpenManage 5.5 or greater is recommended.

- It is recommended that the customer upgrade the management application
and device driver to the latest version available from Dell at the time of
installation of this firmware.

- Before updating the SAS controller firmware using the DUP package in a Linux system, it is necessary to upgrade the SAS controller driver. Executing the SAS controller firmware DUP update while running a native Linux driver may cause the system/data volumes on the SAS controller to become inaccessible or Read-Only.

The recommended steps to update the SAS controller using the firmware DUP package on a Linux system to this new software level are as follows:
1.Upgrade the driver
2.Reboot the system
3.Upgrade thefirmware
4.Reboot the system

The problem does not occur if the SAS controller FW is updated from a bootable device (non Linux environment).
SAS 6/iR Adapter
SAS 6/IR Integrated Blades
Performing the Firmware Upgrade

NOTE: This initial section of the Installation Instructions applies only to configurations with (greater than) 2TB SEDs.

1. Update the firmware version to this version using preferred method below (Zip Pack, Windows DUP, Linux DUP).
2. Reboot for the new FW take effect
3. Un-assign any (greater than) 2TB SED Dedicated or Global Hot Spares in the configuration. Not all configurations have hot spares.
4. Use CTRL-R or OMSS to issue Instant Secure Erase to all un-configured (greater than) 2TB SED drives (all data in these drives will be lost)
5. Re-assign (greater than) 2TB SED Hot Spares.

Zip pack:

Download
1. Click the Download Now link to download the file.
2. When the File Download window appears, click Save to save the file to your
hard drive.

Extract Files
1. Browse to the location where you downloaded the file and double-click the
new file to unzip the download package
2. Click Continue.
3. Specify the location to unzip the files.
4. Click onthe OK button to extract files.
After the files are extracted the message all files were successfully
unzipped will appear.
5. Click the OK button to exit from the installer.

Installation
1. Copy extracted files to bootable media.
2. Reboot system to bootable media.
3. Execute update.bat to perform flash.
5. After flash is complete, remove bootable media.
4. Reboot system for changes to take effect.


Windows Update Package:

Download
1. Click the "Download Now" link to download the file.
2. When the File Download window appears, click Save to save the file to
your hard drive.

Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window
before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.


Linux Update Package:

Download
1. Click the Download Now linkto download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.

Installation
1. Read over the release information presented by executing the
./FRMW_LX_RXXXXXX.BIN --version command from the shell.
2. Download and install any prerequisites identified in the above step before
proceeding.
3. Run the update by executing ./FRMW_LX_RXXXXXX.BIN from the shell.
4. Follow the remaining prompts to perform the update.

GnuPG Signature of Dell Update Package Instructions for FRMW_LX_RXXXXXX.BIN:

Download
1. Click the Download Now link to download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.

Installation
1. Import the Dell public key. (You only need to do this once on your system.)
2. Verify the Dell Update Package by using its signature file, FRMW_LX_RXXXXXX.BIN.

驱动程序帮助和教程