Dell CERC 6/i Integrated FW, v.6.2.0-0013, A11

需要重新启动 已自动安装 此文件是作为最近更新的一部分自动安装的。如果您遇到任何问题,您可以手动下载并重新安装。
此页面的内容可能已自动翻译。要提供反馈,请填写页面底部的表单。
Dell PERC6/CERC6 firmware maintenance release version 6.2.0-0013 Performance enhancements include significant improvements in random-write performance, multi-threaded write performance, and reduction in maximum and average I/O response times.
推荐

查找适合您的系统的最佳下载内容

请输入您的产品详细信息以查看系统的最新驱动程序信息

搜索支持

输入您的戴尔服务编号或型号

想要查找您的产品吗?请输入产品标识符。 演示操作

此驱动程序不兼容

此驱动程序不适用于所选产品。选择另一个产品以重新输入此驱动程序的产品详细信息,或访问产品支持页面以查看其他产品的所有驱动程序。

查找更多更新。使用 SupportAssist 查找适用于您的设备的所有最新驱动程序更新。

补丁和增强功能

1. Enhanced disk IO performance in multiple SAS and SATA configurations.

2. Improved random IO performance.

3. Improved response and completion times for random IO.

4. Increased SATA disk command queue depth.

5. Improved disk medium error correction in certain scenarios.

6. Improved handling of faulty backplanes and enclosures.

7. Resolved an issue where a predicted failure was still being reported after that drive was replaced.

8. Corrected an issue where SATA disks in an MD1000 may become foreign after the server and enclosure are power-cycled.

9. Resolved an issue where the controller could not handle a large number of rebuilds under heavy IO stress.

10. Fixed an issue where Windows Server 2008 installation in uEFI mode fails when installing to a virtual disk larger than 2 terabytes.

11. Fixed an issue where some Intel platforms with a PERC 6 installed occasionally fail with Windows Hardware Malfunction blue screen error during OS reboots.

12. Made several cosmetic and usability enhancements to improved customer experience.
了解详情

版本

6.2.0-0013, A11

发布日期

06 12月 2011

下载类型

固件

类别

SAS RAID

重要性

推荐
Dell Technologies 建议在下一个计划的更新周期期间应用此更新。更新包含用于维护整体系统运行状况的更改。它可确保系统软件保持最新状态并与其他系统模块(固件、BIOS、驱动程序和软件)兼容,并且可能包括其他新功能。
可用格式 查看重要信息

文件格式: 面向MS Windows(32位)的更新包
文件名: RAID_FRMW_WIN_R216022.EXE
文件大小: 5.95 MB
这是一个大文件。根据您的连接速度,可能需要一些时间来下载。
格式说明:
Microsoft Windows 32位格式中的戴尔更新包(DUP)设计为可以在Microsoft Windows 64位操作系统上运行。Microsoft Windows 64位格式中的戴尔更新包(DUP)仅可在Microsoft Windows 64位操作系统上运行。选择设备驱动程序更新时,请务必选择适合您的操作系统的更新。
为确保下载的完整性,请验证校验和值。
MD5:
112E477AC227DBA02A2CDAF8240C24B4
SHA1:
不提供
SHA-256:
不提供

文件格式: 包含加密签名的GnuPG文件
文件名: RAID_FRMW_LX_R216022.BIN.sign
文件大小: 194 Bytes
这是一个大文件。根据您的连接速度,可能需要一些时间来下载。
格式说明:
Red Hat Linux更新包的GnuPG签名可用于验证戴尔在相关Red Hat Linux更新包中的身份。
为确保下载的完整性,请验证校验和值。
MD5:
874E1D2B8086E670730D0873A457644F
SHA1:
不提供
SHA-256:
不提供

文件格式: 外置ZipPack
文件名: DELL_CERC-6-I-INTEGRATED_A11_R216022.exe
文件大小: 1.89 MB
这是一个大文件。根据您的连接速度,可能需要一些时间来下载。
格式说明:
此文件包含一组压缩文件。将文件下载到硬盘上的文件夹中,然后运行(双击)它来解压这组文件。请按照说明完成安装。
为确保下载的完整性,请验证校验和值。
MD5:
9308f538082b21e6ae47885ab19d38e5
SHA1:
a04e333bb06e2a48c293708627e4ad7adbc2fbbe
SHA-256:
不提供

文件格式: 外部版本说明
文件名: R216022.txt
文件大小: 14.35 KB
这是一个大文件。根据您的连接速度,可能需要一些时间来下载。
格式说明:
此文件格式包含纯文本,您可以采用标准文本编辑器进行查看。
为确保下载的完整性,请验证校验和值。
MD5:
0b673803acbc8be9ba23125dd3c139c3
SHA1:
不提供
SHA-256:
不提供

文件格式: Red Hat Linux的更新包
文件名: RAID_FRMW_LX_R216022.BIN
文件大小: 4.45 MB
这是一个大文件。根据您的连接速度,可能需要一些时间来下载。
格式说明:
适用于Linux 的戴 尔更新包是在 满足特定的标准系统环境下使用的独立应用程序。,然后应用更新。
注意:Linux的更新包是开源的。查看适用于Linux 的戴 尔更新包自述以了解 详情,了解详情。
为确保下载的完整性,请验证校验和值。
MD5:
6D8A313070F4B739FD73D6462F861A04
SHA1:
不提供
SHA-256:
不提供

开始下载软件,即表示您接受戴尔软件许可协议 ( 英文版 ) 条款。

1. When viewing SATA physical disk properties from Ctrl-R or other management applications, the Vendor Identification will be translated as "ATA" followed by blanks.

2. If all physical disks making up a virtual disk are removed from the system or enclosure, the RAID controller will delete the virtual disk. If the disks are later re-inserted, they will be marked foreign and can be imported using a management application.

3. If a virtual disk is configured with write-back cache enabled and some or all of its physical disks are removed from the system or enclosure, the RAID controller will preserve the virtual disk's write cache. The controller will flush the preserved cache when the physical disks are replaced and the foreign configuration is imported. Any attempt to update controller firmware will be blocked when cache is preserved for a virtual disk.

4. Physical disks determined to contain a foreign configuration are not available for configuration as a new dedicated or global hot spare, or as a member of a new virtual disk. The foreign configuration must be imported or cleared from the physical disk before it may be used as a hot spare or member of a virtual disk. Physical disks with a foreign configuration will not appear on the Create New VD screen in Ctrl-R.

5. Prior to performing a virtual disk migration to another system, the source system must be powered off before removal of the physical disks to preserve the correct virtual disk state. This is not required for the target system and the physical disks may be inserted while the system is powered on or off.

6. The controller restricts the importing of virtual disks that are undergoing RAID Level Migration or Capacity Expansion. Do not interrupt virtual disks that are performing either of these operations because it will disable the ability to import the virtual disk and the data will be unavailable. Dell recommends that the user perform a data backup before starting these operations.

7. EMM changes or drive migrations are not supported during a Capacity Expansion or Raid Level Migration. This may cause the VDs to go offline. Dell recommends the user to perform a data backup before starting these operations.

8. This version of firmware will not ensure complete compatibility with an older version of management applications. OpenManage 5.5 or greater is recommended.

9. It is recommended that the customer upgrade the management application and device driver to the latest version available from Dell at the time of installation of this firmware.

10. Important Information for Update Packages for Microsoft Windows

a. Do not run other applications while executing Dell Update Packages.
b. Do not run storage controller update packages if the controller is in use
by other applications. The firmware upgrade may fail if any of the
RAID controllers in the system are performing I/O background tasks
(consistency checks, background initializations, rebuilds, or
reconstructions). Allow the background tasks to complete before
attempting to upgrade the firmware. Patrol Read tasks will not affect
firmware upgrades.

11. Important Information for Update Packages for Linux

a. Do not run other applications while executing Dell Update Packages.
b. If the following error occurs, "Error while loading shared libraries:
libstdc++.so.5: cannot open shared object file: No such file or
directory", you must install the compatibility libraries. These
libraries can be found on the installation media or online. To install
the compatibility libraries, use the following commands:
"rpm -ih compat-libstdc++-33-3.2.3.-*.i386.rpm" for RHEL 4 or 5
"rpm -ih compat-libstdc++-5.0.7-*.x86_64.rpm" for SLES 10
c. When Update Packages stop abruptly due to a power outage or abnormal
termination, perform the following steps:
- Remove the lock file.
- Type the following command: rm -f /var/lock/.spsetup
- Run the Update Package again to reapply the update.
d. Do not ru
CERC 6/i Integrated
PERC 6/i Integrated Blade
Performing the Firmware Upgrade

NOTE: This initial section of the Installation Instructions applies only to configurations with (greater than) 2TB SEDs.

1. Update the firmware version to this version using preferred method below (Zip Pack, Windows DUP, Linux DUP).
2. Reboot for the new FW take effect
3. Un-assign any (greater than) 2TB SED Dedicated or Global Hot Spares in the configuration. Not all configurations have hot spares.
4. Use CTRL-R or OMSS to issue Instant Secure Erase to all un-configured (greater than) 2TB SED drives (all data in these drives will be lost)
5. Re-assign (greater than) 2TB SED Hot Spares.

Zip pack:

Download
1. Click the Download Now link to download the file.
2. When the File Download window appears, click Save to save the file to your
hard drive.

Extract Files
1. Browse to the location where you downloaded the file and double-click the
new file to unzip the download package
2. Click Continue.
3. Specify the location to unzip the files.
4. Click onthe OK button to extract files.
After the files are extracted the message all files were successfully
unzipped will appear.
5. Click the OK button to exit from the installer.

Installation
1. Copy extracted files to bootable media.
2. Reboot system to bootable media.
3. Execute update.bat to perform flash.
5. After flash is complete, remove bootable media.
4. Reboot system for changes to take effect.


Windows Update Package:

Download
1. Click the "Download Now" link to download the file.
2. When the File Download window appears, click Save to save the file to
your hard drive.

Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window
before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.


Linux Update Package:

Download
1. Click the Download Now linkto download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.

Installation
1. Read over the release information presented by executing the
./FRMW_LX_RXXXXXX.BIN --version command from the shell.
2. Download and install any prerequisites identified in the above step before
proceeding.
3. Run the update by executing ./FRMW_LX_RXXXXXX.BIN from the shell.
4. Follow the remaining prompts to perform the update.

GnuPG Signature of Dell Update Package Instructions for FRMW_LX_RXXXXXX.BIN:

Download
1. Click the Download Now link to download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.

Installation
1. Import the Dell public key. (You only need to do this once on your system.)
2. Verify the Dell Update Package by using its signature file, FRMW_LX_RXXXXXX.BIN.

驱动程序帮助和教程