Adaptec PERC3/Di, v.2.8.1.6098, A12

已自动安装 此文件是作为最近更新的一部分自动安装的。如果您遇到任何问题,您可以手动下载并重新安装。
此页面的内容可能已自动翻译。要提供反馈,请填写页面底部的表单。
This software contains v2.8.1.6098 Firmware for the PowerEdge PE2650/PowerVault PV775N PERC 3/Di controller.
推荐

查找适合您的系统的最佳下载内容

请输入您的产品详细信息以查看系统的最新驱动程序信息

搜索支持

输入您的戴尔服务编号或型号

想要查找您的产品吗?请输入产品标识符。 演示操作

此驱动程序不兼容

此驱动程序不适用于所选产品。选择另一个产品以重新输入此驱动程序的产品详细信息,或访问产品支持页面以查看其他产品的所有驱动程序。

查找更多更新。使用 SupportAssist 查找适用于您的设备的所有最新驱动程序更新。

补丁和增强功能

Fixes and Enhancements
==========================
2.8.1 Build 6098
----------------
- fixed an issue which occurs when reconfiguring an array with CLI while array was under stress; can result in kernel panic in Linux.
- fixed a bug where a 300GB hard drive could not be assigned as a hot spare for a 300GB R1 using full drive capacities.

2.8.1 Build 6097
----------------
-fixed a defect which occurs when reconfiguring an array to a size greater than 1.09 terabytes; can result in data loss.
–fixed bug where previous firmware did not re-calculate disk capacity when a drive is replaced.

2.8.0 Build 6095
----------------
-single bit change to turn off flag indicating 64-bit compatibility. Needed to fix OMSS Enclosure support issue with RHEL4.

2.8.0 Build 6092
----------------
-Background controller cache flush routine modified to flush smaller number of buffers during I/O without impacting RAID throughput. This change fixes driver timeout (manifesting as loss of drive access and filesystem errors like ext3_get_inode_loc errors) seen under certain Linux configurations.

2.8.0 Build 6089
----------------
-Default changed to 30 Second Timeout for controller BIOS option to pause or continue when RAID configuration is found altered or degraded. This behavior is same as pre v2.8 firmware behavior.

2.8.0 Build 6082 - Initial release of v2.8 firmware
---------------------------------------------------
-The ROMB firmware modified eliminating need for separate SCSI driver when channel-B is configured
as SCSI. Now only one driver is needed for both RAID/RAID and RAID/SCSI configurations (not applicable to PERC2/QC).
-Controller BIOS option added to pause or continue after 30 seconds timeout when RAID configuration is found altered or degraded.
-Additional ESM fix for pulled/missing drives.
-HIM_PCI_ERR correction to power management interrupt.
-Cache flush loop decreased to prevent extensive spin-lock hold during high I/O.
-AFU fix to block firmware installation based on proper level System BIOS.
-SCSI Passthru Event filtering.
-Disallow selection of drive to create raid when already reach maximum limit.
-Disable interrupts around doing queue accesses in CompleteFIB( ).
了解详情

版本

2.8.1.6098, A12

发布日期

13 10月 2005

下载类型

固件

类别

SCSI RAID

重要性

推荐
Dell Technologies 建议在下一个计划的更新周期期间应用此更新。更新包含用于维护整体系统运行状况的更改。它可确保系统软件保持最新状态并与其他系统模块(固件、BIOS、驱动程序和软件)兼容,并且可能包括其他新功能。
可用格式

文件格式: 面向MS Windows(32位)的更新包
文件名: PE2650_PV775N_RAID_FW_WIN_A12.EXE
文件大小: 2.32 MB
这是一个大文件。根据您的连接速度,可能需要一些时间来下载。
格式说明:
Microsoft Windows 32位格式中的戴尔更新包(DUP)设计为可以在Microsoft Windows 64位操作系统上运行。Microsoft Windows 64位格式中的戴尔更新包(DUP)仅可在Microsoft Windows 64位操作系统上运行。选择设备驱动程序更新时,请务必选择适合您的操作系统的更新。
为确保下载的完整性,请验证校验和值。
MD5:
0995C3D801781FA72FF450DC6D843F73
SHA1:
不提供
SHA-256:
不提供

文件格式: 自解压zip内的一个或多个自解压磁盘映像
文件名: PE2650-PV775N-281_6098-A12.exe
文件大小: 1.04 MB
这是一个大文件。根据您的连接速度,可能需要一些时间来下载。
格式说明:
此文件包含一组压缩文件。将文件下载到硬盘上的文件夹中,然后双击它来解压这组文件。请按照说明完成安装。
为确保下载的完整性,请验证校验和值。
MD5:
不提供
SHA1:
不提供
SHA-256:
不提供

文件格式: 包含加密签名的GnuPG文件
文件名: PE2650_PV775N_RAID_FW_LX_A12.BIN.sign
文件大小: 194 Bytes
这是一个大文件。根据您的连接速度,可能需要一些时间来下载。
格式说明:
Red Hat Linux更新包的GnuPG签名可用于验证戴尔在相关Red Hat Linux更新包中的身份。
为确保下载的完整性,请验证校验和值。
MD5:
B6F53D5E542AE62616B44DA223D3F516
SHA1:
不提供
SHA-256:
不提供

文件格式: Red Hat Linux的更新包
文件名: PE2650_PV775N_RAID_FW_LX_A12.BIN
文件大小: 5 MB
这是一个大文件。根据您的连接速度,可能需要一些时间来下载。
格式说明:
适用于Linux 的戴 尔更新包是在 满足特定的标准系统环境下使用的独立应用程序。,然后应用更新。
注意:Linux的更新包是开源的。查看适用于Linux 的戴 尔更新包自述以了解 详情,了解详情。
为确保下载的完整性,请验证校验和值。
MD5:
88F699EB113310A54FDF98A7781774AB
SHA1:
不提供
SHA-256:
不提供

开始下载软件,即表示您接受戴尔软件许可协议 ( 英文版 ) 条款。

PERC3/Di
Instructions for PE2650-PV775N-281_6098-A12.exe

Download

1. Click the Download Now link to download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.

Diskette Creation
1. Browse to the location where you downloaded the file and double-click the new file to create the diskette set.
2. Insert a blank diskette then click Continue.
3. When prompted, repeat step 2 until you reach the end of the diskette set. Label each diskette with a disk number starting from 1.
4. After all the files have been copied to the last diskette, click Finish.


Firmware Installation
=========================
The firmware update utility on this diskette is DOS-based and named AFU.EXE. It offers both interactive and command line modes.


Performing the PERC 3/Di Firmware Upgrade in Interactive Mode
-------------------------------------------------------------
The AFU interactive mode is entered by issuing the AFU command with no command line switches. This mode simplifies the firmware update process for PERC 3/Di when one or more PERC 2/3 controllers are present.

To update the firmware using the AFU interactive mode, follow these steps:

1. Shut down your system.

2. Reboot the system with the diskette labeled:
DELL PERC 3/Di Firmware
Disk 1 of 2

***NOTE: If the system has not been set up to boot from the diskette, please read system documentation for instructions on how to set this up.

3. At the DOS prompt, enter the following command and press ENTER:

A:\> AFU

This starts the AFU in interactive mode. The AFU will detect the integrated PERC 3/Di and any installed PERC 2 controllers and present them for selection in a list.

4. If only PERC 3/Di is detected then AFU will select it. Otherwise, using the arrow keys, highlight PERC 3/Di and select it by pressing the space bar and press ENTER.

5. A "Select an Operation" menu will be presented. Select the following option and press ENTER:

Update flash image

6. The AFU will issue the following message:

Update from the flash image file in directory:
A:
Change the directory if necessary, then use the TAB key to select the OK box, and press ENTER.

7. AFU will issue following message:

Reading flash image file (Build xxxx)...

8. AFU will issue following message after reading flash image from first diskette:

Please insert disk labeled "PERC 3/Di Firmware disk 2"

9. Insert the second diskette and press ENTER.

10. AFU will complete reading the flash image and issue following message:

AFU is about to update firmware on controller(s) Dell PERC 3/Di
*** PLEASE DO NOT REBOOT THE SYSTEM DURING THE UPDATE ***
This might take a few minutes. Select OK to continue.


11. Select the OK box, then press ENTER. AFU will proceed to update the firmware and issue following message:

Writing PERC 3/Di integrated flash image to controller 0 ...

This message will be followed by additional progress messages. When the flash update has completed, you will see this message:

Controller #0 Dell PERC 3/Di
Flash image was updated and verified successfully

***NOTE: If you selected multiple controllers, AFU will prompt you to insert the diskette after the successful update of first controller. Please insert firmware diskette 1 for second controller.

12. Press any key, then press the ESC key to exit AFU. Remove any diskettes from the drive and reboot the system.

***NOTE: System must be rebooted after performing firmware update on PERC 3/Di before attempting any access to drives attached to the controller.

Performing the Controller Firmware Upgrade in Command Line Mode
---------------------------------------------------------------
AFU in command line mode returns its exit status (zero for success or non-zero for an error) in the DOS environment variable ERRORLEVEL.

The following instructions explain how to upgrade the control

驱动程序帮助和教程