Emerson 750W PSU (PN:G24H2) Firmware Package

Genstart er nødvendig AUTOMATISK INSTALLERET Denne fil blev automatisk installeret som en del af en nylig opdatering. Hvis du oplever problemer, kan du downloade og geninstallere manuelt.
Indholdet på denne side er muligvis blevet oversat automatisk. Udfyld formularen nederst på siden for at give feedback.
This package provides the new firmware for power supplier and is supported on Emerson 750W PSU (PN:G24H2) running on the Windows and Linux operating systems.
Anbefalet

Find den bedste download til dit system

Indtast produktoplysningerne for at få vist de seneste driveroplysninger for dit system

Søg i support

Indtast din Dell-servicekode eller -model

Vil du søge efter dit produkt? Indtast et produkt-id. Vis mig hvordan

Denne driver er ikke kompatibel

Denne driver er ikke relevant for det valgte produkt. Vælg et andet produkt for at indtaste dine produktoplysninger for denne driver igen, eller gå til siden Produktsupport for at se alle drivere til et andet produkt.

Find flere opdateringer. Brug SupportAssist til at finde alle de seneste driveropdateringer til din enhed.

Programrettelser og forbedringer

Fixes
- Eliminate communication error issue.

Enhancements
- Not Applicable
Læs mere

Version

M1.0A.04, A01

Udgivelsesdato

09 feb. 2012

Downloadtype

Firmware

Kategori

Strøm

Vigtighed

Valgfrit
Dell Technologies anbefaler at gennemse denne opdatering for at afgøre, om den er relevant for dit system. Opdateringen indeholder ændringer, der kun har indflydelse på visse konfigurationer, eller tilvejebringer nye funktioner, der muligvis passer til dit miljø.
Tilgængelige formater Vis vigtige oplysninger

Filformat: Opdateringspakke til MS Windows 32-bit.
Filnavn: Power_Firmware_0RWJ6_WN32_M1.0A.04_A01.EXE
Filstørrelse: 4.35 MB
Dette er en stor fil. Det kan tage et stykke tid at downloade den, afhængigt af din downloadhastighed.
Formatbeskrivelse:
Dell Update Packages (DUP) i Microsoft Windows 32-bit-format er udviklet til at køre på Microsoft Windows 64-bit-operativsystemer. Dell Update Packages (DUP) i Microsoft Windows 64-bit-format kan kun køre på Microsoft Windows 64-bit-operativsystemer. Når du vælger en driveropdatering, skal du sørge for at vælge den udgave, der passer til dit operativsystem.
Kontrollér kontrolsumværdien for at sikre overførslens integritet.
MD5:
39fe5b65b13fe306bd49b7b3fd58df49
SHA1:
884084fafccd47a9b580b4ef66bdc74f0bf3deff
SHA-256:
b081624558c01cdfe7dd940f63f4051465538bfb02fb1d1f3bf6b60c31eeae45

Filformat: En GnuPG-fil, der indeholder en kryptografisk signatur
Filnavn: Power_Firmware_0RWJ6_LN32_M1.0A.04_A01.BIN.sign
Filstørrelse: 194 Bytes
Dette er en stor fil. Det kan tage et stykke tid at downloade den, afhængigt af din downloadhastighed.
Formatbeskrivelse:
GnuPG-signaturen til Red Hat Linux Update Package kan bruges til at godkende Dells identitet i den samlede Red Hat Linux Update-pakke.
Kontrollér kontrolsumværdien for at sikre overførslens integritet.
MD5:
f3db79d9c9e1237d5778e067c4da987a
SHA1:
9eeacdccf78c9dc499bf593088277f8fefd66248
SHA-256:
5c22de90ab304ead28d78fd32099f61135272df2eaa9f076ddb9f8aa30986fef

Filformat: Eksterne produktbemærkninger
Filnavn: Instructions.txt
Filstørrelse: 3.69 KB
Dette er en stor fil. Det kan tage et stykke tid at downloade den, afhængigt af din downloadhastighed.
Formatbeskrivelse:
Dette filformat indeholder almindelig tekst, som kan vises med en standardteksteditor.
Kontrollér kontrolsumværdien for at sikre overførslens integritet.
MD5:
71773e39d8a855c9cb2b38044da8adb0
SHA1:
e6faa17c155d08d62521d20b34e2c04b271c5593
SHA-256:
Ikke tilgængelig

Filformat: Opdateringspakke til Red Hat Linux
Filnavn: Power_Firmware_0RWJ6_LN32_M1.0A.04_A01.BIN
Filstørrelse: 2.15 MB
Dette er en stor fil. Det kan tage et stykke tid at downloade den, afhængigt af din downloadhastighed.
Formatbeskrivelse:
Dell Update Packages til Linux kan bruges som et selvstændigt program der sikrer, at specifikke valideringskriterier opfyldes, før opdateringen anvendes.
Bemærk: Opdateringspakker til Linux er open-source. Se Vigtigt-filen Dell Update Packages til Linux for at få flere oplysninger.
Kontrollér kontrolsumværdien for at sikre overførslens integritet.
MD5:
b0757c8d625e1771752d9b7320460332
SHA1:
18608cb416a649d2e28eca4e58870d19eac62b3c
SHA-256:
ce534b6b6278aed87e98b3c83fc91decd84e0e7784ba86749723f0ecd3e153ca

Når du downloader filerne, accepterer du samtidig betingelserne i Dells softwarelicensaftale. (på engelsk)

Yderligere oplysninger

Vis alle | Skjul alle
IMPORTANT: After a successful power supply firmware download, the managed system turns off for a duration ranging from three to ten minutes to continue updating the firmware. Once the firmware update is complete, the managed system reboots automatically.

CAUTION! Performing an AC power cycle or cold boot during a power supply firmware update, forces the power supply unit into an irrecoverable state and the managed system does not boot.
750W (F613N) PSU
750W (G24H2) PSU
PSU FIRMWARE UPDATE INSTRUCTIONS:

CAUTION: Performing an AC power cycle or cold boot during a power supply firmware update, forces the power supply unit (PSU) into an irrecoverable state and the managed system does not boot.

IMPORTANT:
After a successful power supply firmware download, the managed system turns off for a duration ranging from three to twenty minutes to continue updating the firmware. It is imperative not to interrupt/restart manually during this time. Update time can vary but should be approximately 10 minutes. Margin should be added to assure the Dell Update Package (DUP) is not interrupted (some DUPs may take up to 20 minutes). Once the firmware update is complete, the managed system reboots automatically.


Instructions for Power_Firmware_0RWJ6_LN32_M1.0A.04_A01.BIN:

Download

1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to your hard drive.

Installation

1. Read the release information presented by executing the ./Power_Firmware_0RWJ6_LN32_M1.0A.04_A01.BIN --version command from the shell.
2. Download and install any prerequisites identified in the above step before proceeding.
3. Run the update by executing ./Power_Firmware_0RWJ6_LN32_M1.0A.04_A01.BIN from the shell.
4. Follow the remaining prompts to perform the update.
5. Upon successful completion the DUP will prompt to reboot system.
6. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
7. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
8. Once the flashing process is complete the system should power back up and boot to OS.


Instructions for Power_Firmware_0RWJ6_WN32_M1.0A.04_A01.EXE:

Download

1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to your hard drive.

Installation

1. Browse to the location where you downloaded the file and double-click the new file.
2. Read the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.
6. Upon successful completion the DUP will prompt to reboot system.
7. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
8. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
9. Once the flashing process is complete the system should power back up and boot to OS.


GnuPG Signature of Dell Update Package Instructions for Power_Firmware_0RWJ6_LN32_M1.0A.04_A01.BIN.sign:

Download

1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to your hard drive.

Installation

1. Import the Dell public key. (You only need to import once on your system.)
2. Verify the Dell Update Package by using its signature file, Power_Firmware_0RWJ6_LN32_M1.0A.04_A01.BIN.sign
3. Upon successful completion the DUP will prompt to reboot system.
4. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
5. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
6. Once the flashing process is complete the system should power back up and boot to OS.

Hjælp og selvstudier til drivere