Dell PERC 5/i Adapter Firmware Update

AUTOMATISK INSTALLERET Denne fil blev automatisk installeret som en del af en nylig opdatering. Hvis du oplever problemer, kan du downloade og geninstallere manuelt.
Indholdet på denne side er muligvis blevet oversat automatisk. Udfyld formularen nederst på siden for at give feedback.
This package provides the Dell PERC 5/i Adapter Firmware Update and is supported on the Enterprise Servers and Powervault models that are running the following Operating System: NA.
Anbefalet

Find den bedste download til dit system

Indtast produktoplysningerne for at få vist de seneste driveroplysninger for dit system

Søg i support

Indtast din Dell-servicekode eller -model

Vil du søge efter dit produkt? Indtast et produkt-id. Vis mig hvordan

Denne driver er ikke kompatibel

Denne driver er ikke relevant for det valgte produkt. Vælg et andet produkt for at indtaste dine produktoplysninger for denne driver igen, eller gå til siden Produktsupport for at se alle drivere til et andet produkt.

Find flere opdateringer. Brug SupportAssist til at finde alle de seneste driveropdateringer til din enhed.

Programrettelser og forbedringer

Fixes
- DeviceType on the Device Manager display has been corrected to show the proper device type: RAID
- Disk Timeout has been increased from 60 seconds to 65 seconds to safely allow drives to complete recovery.

Enhancements
- Added a bus rescan after a logical volume are initialized to effectively remove stale data. This will allow the OS to invalidate its cache data.
Læs mere

Version

5.2.2-0072, A09

Udgivelsesdato

09 maj 2012

Downloadtype

Firmware

Kategori

SAS RAID

Vigtighed

Anbefalet
Dell Technologies anbefaler, at denne opdatering installeres under den næste planlagte opdateringscyklus. Opdateringen indeholder ændringer, der skal opretholde systemets generelle tilstand. Den sørger for, at systemsoftwaren forbliver opdateret og kompatibel med andre systemmoduler (firmware, BIOS, drivere og software) og kan indeholde andre nye funktioner.
Tilgængelige formater Vis vigtige oplysninger

Filformat: Opdateringspakke til MS Windows 32-bit.
Filnavn: SAS-RAID_Firmware_10DNJ_WN32_5.2.2-0072_A09.EXE
Filstørrelse: 6.24 MB
Dette er en stor fil. Det kan tage et stykke tid at downloade den, afhængigt af din downloadhastighed.
Formatbeskrivelse:
Dell Update Packages (DUP) i Microsoft Windows 32-bit-format er udviklet til at køre på Microsoft Windows 64-bit-operativsystemer. Dell Update Packages (DUP) i Microsoft Windows 64-bit-format kan kun køre på Microsoft Windows 64-bit-operativsystemer. Når du vælger en driveropdatering, skal du sørge for at vælge den udgave, der passer til dit operativsystem.
Kontrollér kontrolsumværdien for at sikre overførslens integritet.
MD5:
b38627244896f9ec0c22b4c4255f9cba
SHA1:
ee612c6ba3e9917d2d58514f888ba4a713d968ec
SHA-256:
Ikke tilgængelig

Filformat: En eller flere selvudpakkende diskimages i en selvudpakkende zipfil
Filnavn: BR189331.exe
Filstørrelse: 1.54 MB
Dette er en stor fil. Det kan tage et stykke tid at downloade den, afhængigt af din downloadhastighed.
Formatbeskrivelse:
Denne fil indeholder komprimerede (eller ZIP) filer. Hent filen til en mappe på din harddisk, og dobbeltklik derefter på den for at udpakke filerne. Følg instruktionerne for at fuldføre installationen.
Kontrollér kontrolsumværdien for at sikre overførslens integritet.
MD5:
6ac7c139a3b6832f83df162a1079d38c
SHA1:
Ikke tilgængelig
SHA-256:
Ikke tilgængelig

Filformat: En GnuPG-fil, der indeholder en kryptografisk signatur
Filnavn: SAS-RAID_Firmware_10DNJ_LN32_5.2.2-0072_A09.BIN.sign
Filstørrelse: 194 Bytes
Dette er en stor fil. Det kan tage et stykke tid at downloade den, afhængigt af din downloadhastighed.
Formatbeskrivelse:
GnuPG-signaturen til Red Hat Linux Update Package kan bruges til at godkende Dells identitet i den samlede Red Hat Linux Update-pakke.
Kontrollér kontrolsumværdien for at sikre overførslens integritet.
MD5:
ef8ab60f2fdd1486c793796f5d13bd3c
SHA1:
e64239b4f43e682dd2ddbfb68f66c43989c71b7c
SHA-256:
Ikke tilgængelig

Filformat: ZipPack-ekstern
Filnavn: DELL_PERC-5-I-ADAPTER_A09_R189331.exe
Filstørrelse: 1.29 MB
Dette er en stor fil. Det kan tage et stykke tid at downloade den, afhængigt af din downloadhastighed.
Formatbeskrivelse:
Denne fil indeholder komprimerede (eller ZIP) filer. Hent filen til en mappe på din harddisk, og kør den derefter (dobbeltklik) for at udpakke filerne. Følg instruktionerne for at fuldføre installationen.
Kontrollér kontrolsumværdien for at sikre overførslens integritet.
MD5:
1465ae7c9e94bfcae536ec1d468303a8
SHA1:
d0afe4d46b4c695cebf0c3c896f2be223542695a
SHA-256:
Ikke tilgængelig

Filformat: Eksterne produktbemærkninger
Filnavn: R189331.txt
Filstørrelse: 13.54 KB
Dette er en stor fil. Det kan tage et stykke tid at downloade den, afhængigt af din downloadhastighed.
Formatbeskrivelse:
Dette filformat indeholder almindelig tekst, som kan vises med en standardteksteditor.
Kontrollér kontrolsumværdien for at sikre overførslens integritet.
MD5:
6db0e46508e97ee65ea117a7f85cd0d1
SHA1:
Ikke tilgængelig
SHA-256:
Ikke tilgængelig

Filformat: Opdateringspakke til Red Hat Linux
Filnavn: SAS-RAID_Firmware_10DNJ_LN32_5.2.2-0072_A09.BIN
Filstørrelse: 4.31 MB
Dette er en stor fil. Det kan tage et stykke tid at downloade den, afhængigt af din downloadhastighed.
Formatbeskrivelse:
Dell Update Packages til Linux kan bruges som et selvstændigt program der sikrer, at specifikke valideringskriterier opfyldes, før opdateringen anvendes.
Bemærk: Opdateringspakker til Linux er open-source. Se Vigtigt-filen Dell Update Packages til Linux for at få flere oplysninger.
Kontrollér kontrolsumværdien for at sikre overførslens integritet.
MD5:
3e70db8f2b482562d37334d3db91f9e5
SHA1:
1389022e9c60ac3256b42cbe08e79ddc8cc8cc27
SHA-256:
Ikke tilgængelig

Når du downloader filerne, accepterer du samtidig betingelserne i Dells softwarelicensaftale. (på engelsk)

Yderligere oplysninger

Vis alle | Skjul alle
1. All RAID volumes will be presented as write through (WT) to the operating system (Windows and linux) independent of the actual write cache policy of the virtual disk.The controller manages the data in cache independently of the OS and any applications.Please use OpenManage or the BIOS Configuration Utility to view and manage virtual disk cache settings.

2. When viewing SATA physical disk properties from Ctrl-R or other management applications, the Vendor Identification.

3. If all physical disks making up a virtual disk are removed from the system or enclosure, the RAID controller will delete the virtual disk. If the disks are later re-inserted, they will be marked foreign and can be imported using a management application.

4. If the cable connecting a PERC 5/E to an enclosure is removed, the RAID controller will immediately delete all virtual disks on that enclosure. To recover, power down the server and ensure all cables in the configuration are securely connected. When the server is powered on, the RAID controller will detect the disks as foreign and the configuration can be imported with a management application.

5. Physical disks determined to contain a foreign configuration are not available for configuration as a new dedicated or global hotspare, or as a member of a new virtual disk. The foreign configuration must be imported or cleared from the physical disk before it may be used as a hotspare or member of a virtual disk. Physical disks with a foreign configuration will not appear on the Create New VD screen in Ctrl-R.

6. Prior to performing a virtual disk migration, the source system must be powered off before removal of the physical disks to preserve the correct virtual disk state. This is not required for the target system and the physical disks may be inserted while the system is powered on or off.

7. This version of firmware will not ensure complete compatibility with an older version of the management application, OpenManage 5.0 or 5.1.OpenManage 5.2 or greater is recommended.

8. It is recommended that the customer upgrade the management application and device driver to the latest version available from Dell at the time of installation of this firmware.

9. The firmware restricts the importing of virtual disks that are undergoing RAID level migration or Capacity Expansion. Do not interrupt virtual disks that are performing either of these operations because it will disable the ability to import the virtual disk and the data will be unavailable. Dell recommends that the user perform a data backup before starting these operations.

10. Foreign dedicated hot spares are now imported as global hot spares.

11. Default Physical disk cache settings for hard drives are ON for SATA drives and OFF for SAS drives.

12. A EMM change or a drive migration is not a supported action during a Capacity Expansion or Raid Level Migration. This may cause the VDs to go offline.Dell recommends the user to take a data backup before starting these operations.

13. A Rebuild operation cannot be stopped/interrupted from the Ctrl+R configuration utility but can be done from the Dell Open Manage Storage Management Software.
PERC 5/i Adapter
2.0 Performing the Firmware Upgrade
===================================

Web pack:
---------

Download
1. Click Download Now, to download the file.
2. When the File Download window appears, click Save
this program to disk and click OK. The Save In: window appears.
3. From the "Save As" field, click the down arrow then click to
select Desktop and click Save. The file will download to your desktop.
4. If the Download Complete window appears, click Close. The file
icon appears on your desktop.

Hard Drive Floppy Disk Creation
1. Get 2 blank, formatted floppy disks.
2. Double-click the new icon (it looks like a floppy diskette) on
the desktop. The Self-Extractor window appears.
3. Click the 'Continue' button on the self-extractor window after inserting
one of the formatted floppies.
4. The utility prompts the user to insert the second floppy diskette after
it completes writing on the first floppy.
5. Remove the first floppy and insert the second floppy diskette.
6. Press 'Continue' button.
7. After all the files have been copied to the last floppy disk, press the 'Finish'
button to close the Self-Extracter window

Install
1. Insert the first (or the only) disk of the set into the Floppy
drive.
2. Click Start, click Shutdown, click Restart, and then click OK.
3. Follow the on-screen instructions.

Zip pack:
---------

Download
1. Click the Download Now link to download the file.
2. When the File Download window appears, click Save to save the file to
your hard drive.

Extract Files
1. Browse to the location where you downloaded the file and double-click the
new file to unzip the download package
2. Click Continue.
3. Specify the location to unzip the files.
4. Click on the OK button to extract files.
After the files are extracted the message all files were successfully
unzipped will appear.
5. Click the OK button to exit from the installer.

Installation
1. Copy extracted files to bootable media.
2. Reboot system to bootable media.
3. Execute update.bat to perform flash.
4. After flash is complete, remove bootable media.
5. Reboot system for changes to take effect.

Windows Update Package:
-----------------------

Download
1. Click the "Download Now" link to download the file.
2. When the File Download window appears, click "Save" to save the file to
your hard drive.

Installation
1. Browse to the location where you downloaded the file and double-click
the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window
before proceeding.
4. Click the "Install" button.
5. Follow the remaining prompts to perform the update.

Linux Update Package:
---------------------

Download
1. Click the "Download Now" link to download the file.
2. When the File Download window appears, click "Save" to save the file to
your hard drive.

Installation
1. Read over the release information presented by executing the
"./FRMW_LX_RXXXXXX.BIN --version" command from the shell.
2. Download and install any prerequisites identified in the above step before
proceeding.
3. Run the update by executing "./FRMW_LX_RXXXXXX.BIN" from the shell.
4. Follow the remaining prompts to perform the update.

GnuPG Signature of Dell Update Package Instructions for FRMW_LX_RXXXXXX.BIN:
----------------------------------------------------------------------------

Download
1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to
your hard drive.

Installation
1. Import the Dell public key. (You only need to do this once on your system.)
2. Verify the Dell Update Package by using its signature file,
FRMW_LX_RXXXXXX.BIN.

Hjælp og selvstudier til drivere