Emerson 750W PSU (PN: 79RDR) Firmware Package

Genstart er nødvendig AUTOMATISK INSTALLERET Denne fil blev automatisk installeret som en del af en nylig opdatering. Hvis du oplever problemer, kan du downloade og geninstallere manuelt.
Indholdet på denne side er muligvis blevet oversat automatisk. Udfyld formularen nederst på siden for at give feedback.
This package provides the new firmware for power supplier and is supported on Emerson 750W PSU (PN: 79RDR) running on the Windows and Linux operating systems.
Anbefalet

Find den bedste download til dit system

Indtast produktoplysningerne for at få vist de seneste driveroplysninger for dit system

Søg i support

Indtast din Dell-servicekode eller -model

Vil du søge efter dit produkt? Indtast et produkt-id. Vis mig hvordan

Denne driver er ikke kompatibel

Denne driver er ikke relevant for det valgte produkt. Vælg et andet produkt for at indtaste dine produktoplysninger for denne driver igen, eller gå til siden Produktsupport for at se alle drivere til et andet produkt.

Find flere opdateringer. Brug SupportAssist til at finde alle de seneste driveropdateringer til din enhed.

Programrettelser og forbedringer

Fixes
- The current sharing does not work in some power supplies.

Enhancements
- Not Applicable
Læs mere

Version

07.09.41, A01

Udgivelsesdato

24 dec. 2012

Downloadtype

Firmware

Kategori

Strøm

Vigtighed

Vigtigt
Dell Technologies anbefaler på det kraftigste, at denne opdatering installeres så hurtigt som muligt. Opdateringen indeholder vigtige fejlrettelser og ændringer med henblik på at forbedre dit Dell-systems funktionalitet, pålidelighed og stabilitet. Den kan også omfatte sikkerhedsrettelser og andre funktionsforbedringer.
Tilgængelige formater Vis vigtige oplysninger

Filformat: Opdateringspakke til MS Windows 32-bit.
Filnavn: Power_Firmware_DTCN4_WN32_07.09.41_A01.EXE
Filstørrelse: 8.23 MB
Dette er en stor fil. Det kan tage et stykke tid at downloade den, afhængigt af din downloadhastighed.
Formatbeskrivelse:
Dell Update Packages (DUP) i Microsoft Windows 32-bit-format er udviklet til at køre på Microsoft Windows 64-bit-operativsystemer. Dell Update Packages (DUP) i Microsoft Windows 64-bit-format kan kun køre på Microsoft Windows 64-bit-operativsystemer. Når du vælger en driveropdatering, skal du sørge for at vælge den udgave, der passer til dit operativsystem.
Kontrollér kontrolsumværdien for at sikre overførslens integritet.
MD5:
34b32076ecb91b17cd25db21f24149f1
SHA1:
103962bc35bf0f18caafce298f8729c0b45df927
SHA-256:
ce7c189de6a1806dd8aa3606eef3b07cbdbbe4c6a01542b1cae44d13eb8ebe1a

Filformat: En GnuPG-fil, der indeholder en kryptografisk signatur
Filnavn: Power_Firmware_DTCN4_LN_07.09.41_A01.BIN.sign
Filstørrelse: 194 Bytes
Dette er en stor fil. Det kan tage et stykke tid at downloade den, afhængigt af din downloadhastighed.
Formatbeskrivelse:
GnuPG-signaturen til Red Hat Linux Update Package kan bruges til at godkende Dells identitet i den samlede Red Hat Linux Update-pakke.
Kontrollér kontrolsumværdien for at sikre overførslens integritet.
MD5:
9ff8b0e0486807cc51dc0c8d2ded2d73
SHA1:
cb35298e03751c63a15e448daba13bd3286fc9ac
SHA-256:
3b830b03216e7059240c357cf480232cdd6dd7b9ce7bacc960d3dd073215b94e

Filformat: Opdateringspakke til Red Hat Linux
Filnavn: Power_Firmware_DTCN4_LN_07.09.41_A01.BIN
Filstørrelse: 6.62 MB
Dette er en stor fil. Det kan tage et stykke tid at downloade den, afhængigt af din downloadhastighed.
Formatbeskrivelse:
Dell Update Packages til Linux kan bruges som et selvstændigt program der sikrer, at specifikke valideringskriterier opfyldes, før opdateringen anvendes.
Bemærk: Opdateringspakker til Linux er open-source. Se Vigtigt-filen Dell Update Packages til Linux for at få flere oplysninger.
Kontrollér kontrolsumværdien for at sikre overførslens integritet.
MD5:
442c3563f7d5bc20d9734a1d551e36d8
SHA1:
406ab2d500403dacdab5b3ba155be08919faa63c
SHA-256:
358f1454b3a33ba5f955601868f3b508355ae41ab6115e2cab757f65cbd7628f

Når du downloader filerne, accepterer du samtidig betingelserne i Dells softwarelicensaftale. (på engelsk)

Yderligere oplysninger

Vis alle | Skjul alle
IMPORTANT: After a successful power supply firmware download, the managed system turns off for a duration ranging from three to ten minutes to continue updating the firmware. Once the firmware update is complete, the managed system reboots automatically.

CAUTION! Performing an AC power cycle or cold boot during a power supply firmware update, forces the power supply unit into an irrecoverable state and the managed system does not boot.
Emerson 750W PSU (PN: 79RDR)
SWB,FIRMWARE,AC750,EMSN
SWB,FIRMWARE,AC750,EMSN,V2
PSU FIRMWARE UPDATE INSTRUCTIONS:

CAUTION: Performing an AC power cycle or cold boot during a power supply firmware update, forces the power supply unit (PSU) into an irrecoverable state and the managed system does not boot.

IMPORTANT:
After a successful power supply firmware download, the managed system turns off for a duration ranging from three to twenty minutes to continue updating the firmware. It is imperative not to interrupt/restart manually during this time. Update time can vary but should be approximately 10 minutes. Margin should be added to assure the Dell Update Package (DUP) is not interrupted (some DUPs may take up to 20 minutes). Once the firmware update is complete, the managed system reboots automatically.


Instructions for ".BIN" file:

Download
1. Click the Download Now link to download the file.
2. When the "File Download" window appears, click Save to save the file to your hard drive.

Installation
1. Read the release information presented by executing the ".BIN" file with "--version" command from the shell.
2. Download and install any prerequisites identified in the above step before proceeding.
3. Run the update by executing ".BIN" file from the shell.
4. Follow the remaining prompts to perform the update.
5. Upon successful completion the DUP will prompt to reboot system.
6. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
7. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
8. Once the flashing process is complete the system should power back up and boot to OS.

Instructions for ".EXE" file:

Download
1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to your hard drive.

Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.
6. Upon successful completion the DUP will prompt to reboot system.
7. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
8. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
9. Once the flashing process is complete the system should power back up and boot to OS.


GnuPG Signature of Dell Update Package Instructions for ".sign" file:

Download
1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to your hard drive.

Installation
1. Import the Dell public key. (You only need to import once on your system.)
2. Verify the Dell Update Package by using its signature file.
3. Upon successful completion the DUP will prompt to reboot system.
4. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
5. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
6. Once the flashing process is complete the system should power back up and boot to OS.