LiteOn 1100W PSU (PN: GYH9V) Firmware Package

Genstart er nødvendig AUTOMATISK INSTALLERET Denne fil blev automatisk installeret som en del af en nylig opdatering. Hvis du oplever problemer, kan du downloade og geninstallere manuelt.
Indholdet på denne side er muligvis blevet oversat automatisk. Udfyld formularen nederst på siden for at give feedback.
This package provides the new firmware for power supplier and is supported on LiteOn 1100W PSU (PN: GYH9V) running on the Windows and Linux operating systems.
Anbefalet

Find den bedste download til dit system

Indtast produktoplysningerne for at få vist de seneste driveroplysninger for dit system

Søg i support

Indtast din Dell-servicekode eller -model

Vil du søge efter dit produkt? Indtast et produkt-id. Vis mig hvordan

Denne driver er ikke kompatibel

Denne driver er ikke relevant for det valgte produkt. Vælg et andet produkt for at indtaste dine produktoplysninger for denne driver igen, eller gå til siden Produktsupport for at se alle drivere til et andet produkt.

Find flere opdateringer. Brug SupportAssist til at finde alle de seneste driveropdateringer til din enhed.

Programrettelser og forbedringer

The first Initial version
Læs mere

Version

07.12.52, A00-01

Udgivelsesdato

06 mar. 2012

Downloadtype

Firmware

Kategori

Strøm

Vigtighed

Valgfrit
Dell Technologies anbefaler at gennemse denne opdatering for at afgøre, om den er relevant for dit system. Opdateringen indeholder ændringer, der kun har indflydelse på visse konfigurationer, eller tilvejebringer nye funktioner, der muligvis passer til dit miljø.
Tilgængelige formater Vis vigtige oplysninger

Filformat: Opdateringspakke til MS Windows 32-bit.
Filnavn: Power_Firmware_N9V70_WN32_07.12.52_A00-01.EXE
Filstørrelse: 4.36 MB
Dette er en stor fil. Det kan tage et stykke tid at downloade den, afhængigt af din downloadhastighed.
Formatbeskrivelse:
Dell Update Packages (DUP) i Microsoft Windows 32-bit-format er udviklet til at køre på Microsoft Windows 64-bit-operativsystemer. Dell Update Packages (DUP) i Microsoft Windows 64-bit-format kan kun køre på Microsoft Windows 64-bit-operativsystemer. Når du vælger en driveropdatering, skal du sørge for at vælge den udgave, der passer til dit operativsystem.
Kontrollér kontrolsumværdien for at sikre overførslens integritet.
MD5:
e173db44a470cfef6886bcfdbb1706b4
SHA1:
7e67a04d3294bdd3529b1334cbc58872eb9617a1
SHA-256:
19f858f5c6199e622e842813e58126aa75615ab3b3e855fe08bb44d591942ad7

Filformat: En GnuPG-fil, der indeholder en kryptografisk signatur
Filnavn: Power_Firmware_N9V70_LN32_07.12.52_A00-01.BIN.sign
Filstørrelse: 194 Bytes
Dette er en stor fil. Det kan tage et stykke tid at downloade den, afhængigt af din downloadhastighed.
Formatbeskrivelse:
GnuPG-signaturen til Red Hat Linux Update Package kan bruges til at godkende Dells identitet i den samlede Red Hat Linux Update-pakke.
Kontrollér kontrolsumværdien for at sikre overførslens integritet.
MD5:
03a6db08a94ce108347f3f815966eb7c
SHA1:
c6d4fe67a67dd26c231a88fe1eb7844994f588c6
SHA-256:
60c8dd1552aee88b4c2ce8d3ce31a44108467edb99cb52da0c87ee85a2ed2e3c

Filformat: Opdateringspakke til Red Hat Linux
Filnavn: Power_Firmware_N9V70_LN32_07.12.52_A00-01.BIN
Filstørrelse: 2.17 MB
Dette er en stor fil. Det kan tage et stykke tid at downloade den, afhængigt af din downloadhastighed.
Formatbeskrivelse:
Dell Update Packages til Linux kan bruges som et selvstændigt program der sikrer, at specifikke valideringskriterier opfyldes, før opdateringen anvendes.
Bemærk: Opdateringspakker til Linux er open-source. Se Vigtigt-filen Dell Update Packages til Linux for at få flere oplysninger.
Kontrollér kontrolsumværdien for at sikre overførslens integritet.
MD5:
321a86b9aad8439a6be5563583092572
SHA1:
5d4f42916cbf29c520b495f34086354d4bd05793
SHA-256:
f6ead45abe0318537da5528023f39ce1678b6345da3a48a5e5e493ca80db4bb4

Når du downloader filerne, accepterer du samtidig betingelserne i Dells softwarelicensaftale. (på engelsk)

Yderligere oplysninger

Vis alle | Skjul alle
IMPORTANT: After a successful power supply firmware download, the managed system turns off for a duration ranging from three to ten minutes to continue updating the firmware. Once the firmware update is complete, the managed system reboots automatically.

CAUTION! Performing an AC power cycle or cold boot during a power supply firmware update, forces the power supply unit into an irrecoverable state and the managed system does not boot.
ASSY,PWR SPLY,1100W,RDNT,LTON
LiteOn 1100W PSU (PN: GYH9V)
PSU FIRMWARE UPDATE INSTRUCTIONS:

CAUTION: Performing an AC power cycle or cold boot during a power supply firmware update, forces the power supply unit (PSU) into an irrecoverable state and the managed system does not boot.

IMPORTANT:
After a successful power supply firmware download, the managed system turns off for a duration ranging from three to twenty minutes to continue updating the firmware. It is imperative not to interrupt/restart manually during this time. Update time can vary but should be approximately 10 minutes. Margin should be added to assure the Dell Update Package (DUP) is not interrupted (some DUPs may take up to 20 minutes). Once the firmware update is complete, the managed system reboots automatically.


Instructions for ".BIN" file:

Download
1. Click the Download Now link to download the file.
2. When the "File Download" window appears, click Save to save the file to your hard drive.

Installation
1. Read the release information presented by executing the".BIN" file with "--version" command from the shell.
2. Download and install any prerequisites identified in the above step before proceeding.
3. Run the update by executing ".BIN" file from the shell.
4. Follow the remaining prompts to perform the update.
5. Upon successful completion the DUP will prompt to reboot system.
6. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
7. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
8. Once the flashing process is complete the system should power back up and boot to OS.

Instructions for ".EXE" file:

Download
1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to your hard drive.

Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.
6. Upon successful completion the DUP will prompt to reboot system.
7. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
8. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
9. Once the flashing process is complete the system should power back up and boot to OS.


GnuPG Signature of Dell Update Package Instructions for ".sign" file:

Download
1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to your hard drive.

Installation
1. Import the Dell public key. (You only need to import once on your system.)
2. Verify the Dell Update Package by using its signature file.
3. Upon successful completion the DUP will prompt to reboot system.
4. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
5. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
6. Once the flashing process is complete the system should power back up and boot to OS.
IMPORTANT: After a successful power supply firmware download, the managed system turns off for a duration ranging from three to ten minutes to continue updating the firmware. Once the firmware update is complete, the managed system reboots automatically.

CAUTION! Performing an AC power cycle or cold boot during a power supply firmware update, forces the power supply unit into an irrecoverable state and the managed system does not boot.

Hjælp og selvstudier til drivere