SES 1.9.5 Test Release Notes
The SES195.bin file is the required file for the download. It is highly recommended that all I/O is stopped before beginning this procedure.
You must update the SES firmware on each LS module in the PowerVault 660 and each of the attached enclosures. This includes the 660F as well as all attached 224F enclosures.
If you are replacing an LS module, or adding new PowerVault 224 units to an existing subsystem, you should update all LS modules with this firmware.
Enclosure services must be online to update the firmware. If enclosure services are offline then restore them to the online state before performing the following procedure.
Anbefalet
Find den bedste download til dit system
Indtast produktoplysningerne for at få vist de seneste driveroplysninger for dit system
Søg i support
Indtast din Dell-servicekode eller -model
Vil du søge efter dit produkt? Indtast et produkt-id.Vis mig hvordan
Søgningen gav ingen resultater.Vi kunne ikke finde nogen match til din søgning. Rediger din søgning, og prøv igen.
Denne driver er ikke kompatibel
Denne driver er ikke relevant for det valgte produkt. Vælg et andet produkt for at indtaste dine produktoplysninger for denne driver igen, eller gå til siden Produktsupport for at se alle drivere til et andet produkt.
Log på Windows som administrator for at bruge automatisk scanning. Hvis du allerede er logget på som administrator og får vist denne meddelelse, skal du genstarte enheden.Dit system administreres af din it-administrator, og funktionaliteten kan være begrænset.
Find flere opdateringer. Brug SupportAssist til at finde alle de seneste driveropdateringer til din enhed.
Programrettelser og forbedringer
Improvements to SES 1.9.5 SES 1.9.5 enhances the communication between SES modules. In the past there were times when thresholds set on the master SES were not copied to the slave SES. In a failover scenario the slave would apply the old values, requiring that the user reset the new thresholds.
SES 1.9.5 enhances reporting so that when an LS module fails, Dell Open Manage Array Manager can report the problem. The LED for the LS module will, as in previous versions, still light when an LS module is in a failed state.
SES 1.9.5 now reports the correct model name of the system, either PV660 or PV224.
In SES 1.3b2, upper warning/critical for LS Module temperature sensors is 45C/55C and for power supply sensors is 55C/65C, which is incorrect. The correct settings are in SES 1.9.5 and are 35C/45C for the LS module temperature sensors and 45C/55C for the power supply.
Dell Technologies anbefaler at gennemse denne opdatering for at afgøre, om den er relevant for dit system. Opdateringen indeholder ændringer, der kun har indflydelse på visse konfigurationer, eller tilvejebringer nye funktioner, der muligvis passer til dit miljø.
To update the LS module SES firmware, perform the following steps:
1. Start Array Manager on the host system by clicking Start-- Programs-- Dell OpenManage Applications-- Array Manager-- Array Manager Console.
2. Update the SES firmware on the PowerVault 660F.
a. Click Arrays-- PV660F SubSystem-- Physical Array.
b. Right-click the controller for the subsystem you wish to upgrade and choose Download-- SES Firmware.
c. Select all the enclosure check boxes and click Next.
d. Click Browse and locate the SES195.bin file. Click Next.
e. Click Finish and OK.
NOTE: This process takes about 8 to 9 minutes for each additional LS module in the storage array. If the firmware update does not complete successfully, repeat the process until it does. This issue is not a hardware problem, but a software-timing issue.
f. After download completes, right-click the PV660F subsystem in Array Manager and choose Rescan to update the properties information.
g. Right-click the enclosure in Array Manager, choose Properties, and verify that it is using SES firmware version 1.9.5. If it is not, repeat the download procedure.
h. Physically remove the primary LS module to cause failover.
i. Right-click the PV660F subsystem in Array Manager and choose Rescan to update the properties information.
j. Right-click the enclosure and choose Properties to verify its firmware level is also at version 1.9.5. If it is not, repeat the download procedure.
k. Replace the LS module that you removed. If you have multiple enclosures, you must verify the firmware level on every LS module in the subsystem, one at a time.