Delta 495W PSU (PN: GRTNK, 2FR04) Firmware Package

Restart required AUTO INSTALLED This file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
This package provides the new firmware for power supplier and is supported on Delta 495W PSU (PN: GRTNK, 2FR04).
Recommended

Find the best download for your system

Please enter your product details to view the latest driver information for your system

Search support

Enter your Dell Service Tag or model

Want to look up your product? Enter a product identifier. Show me how

This driver is not compatible

This driver is not applicable for the selected product. Choose another product to re-enter your product details for this driver or visit the Product Support page to view all drivers for a different product.

Find more updates. Use SupportAssist to find all the latest driver updates for your device.

Fixes & Enhancements

[For GRTNK]
Iniital Release.

[For 2FR04]
Fix:
- N/A.
Enhancement:
- PSU FW corruption recovery
- For 4 PSU configuration Hot-Spare behavior
Read More

Version

00.1B.7A, 00.1B.7A

Release date

11 May 2016

Download Type

Firmware

Category

Power

Importance

Recommended
Dell Technologies recommends applying this update during your next scheduled update cycle. The update contains changes to maintain overall system health. It ensures that the system software remains current and compatible with other system modules (firmware, BIOS, drivers, and software) and may include other new features.
Available formats

File Format: Update Package for MS Windows 64-Bit.
File Name: Power_Firmware_J5WKD_WN64_00.1B.7A.EXE
File Size: 12.14 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages in native Microsoft Windows 64-bit format do not require that Microsoft WOW64 be installed on the Microsoft Windows Server.
To ensure the integrity of your download, please verify the checksum value.
MD5:
8bd2d85d1fde39ee95bae8afd30f69ec
SHA1:
92487c9dd83ac1fa525e36e8526c6749b2affb01
SHA-256:
78d1927c45d9bc06e7ecccc29981074fe14d465eba02694884f6178272756b3a

File Format: A GnuPG file which contains a cryptographic signature
File Name: Power_Firmware_J5WKD_LN_00.1B.7A.BIN.sign
File Size: 194 Bytes
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
The GnuPG signature for Red Hat Linux Update Package can be used to authenticate Dell's identity in the correlated Red Hat Linux Update Package.
To ensure the integrity of your download, please verify the checksum value.
MD5:
23095788e3cf2050751f53eb3c3eb3d4
SHA1:
ffd1b7adb75b6644cdbcf6d68aab4be7d9bb4d7f
SHA-256:
7b8e6cb41fa052fee1ec5664a0fa3e2c5ef813ce6fe6113d7c5d75a6a6b64588

File Format: Update Package for MS Windows 32-Bit
File Name: Power_Firmware_J5WKD_WN32_00.1B.7A.EXE
File Size: 6.82 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages (DUP) in Microsoft Windows 32bit format have been designed to run on Microsoft Windows 64bit Operating Systems. Dell Update Packages (DUP) in Microsoft Windows 64bit format will only run on Microsoft Windows 64bit Operating Systems. When selecting a device driver update be sure to select the one that is appropriate for your operating system.
To ensure the integrity of your download, please verify the checksum value.
MD5:
288db6586495651bea1d4e0983bbec4c
SHA1:
1f3cb1bd8acefc936190a9dc976773b68482996f
SHA-256:
a15227a40d5aef31ac174dd980fd385b89396aee8e104bbcf24780867da228c7

File Format: Update Package for Red Hat Linux
File Name: Power_Firmware_J5WKD_LN_00.1B.7A.BIN
File Size: 34.35 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages for Linux can be used as stand-alone applications that ensure that specific validation criteria are met, then apply an update.
Note: Update Packages for Linux are open source. See the Dell Update Packages for Linux Readme for details.
To ensure the integrity of your download, please verify the checksum value.
MD5:
012fd2fb2fee294281463676124e88f3
SHA1:
fcb0ac3eac8cd40ce0cc2b386c6738d8747d7ce1
SHA-256:
a814edb3aa8cab75e148f6d9ae0488cfbe18a5011f02604c3ceec69f70944834

By downloading, you accept the terms of the Dell Software License Agreement.

Additional details

Show All | Hide All
Delta 495W PSU
PSU FIRMWARE UPDATE INSTRUCTIONS:

CAUTION: Performing an AC power cycle or cold boot during a power supply firmware update, forces the power supply unit (PSU) into an irrecoverable state and the managed system does not boot.

IMPORTANT:
After a successful power supply firmware download, the managed system turns off for a duration ranging from three to twenty minutes to continue updating the firmware. It is imperative not to interrupt/restart manually during this time. Update time can vary but should be approximately 10 minutes. Margin should be added to assure the Dell Update Package (DUP) is not interrupted (some DUPs may take up to 20 minutes). Once the firmware update is complete, the managed system reboots automatically.


Instructions for ".BIN" file:

Download
1. Click the Download Now link to download the file.
2. When the "File Download" window appears, click Save to save the file to your hard drive.

Installation
1. Read the release information presented by executing the".BIN" file with "--version" command from the shell.
2. Download and install any prerequisites identified in the above step before proceeding.
3. Run the update by executing ".BIN" file from the shell.
4. Follow the remaining prompts to perform the update.
5. Upon successful completion the DUP will prompt to reboot system.
6. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
7. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
8. Once the flashing process is complete the system should power back up and boot to OS.

Instructions for ".EXE" file:

Download
1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to your hard drive.

Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.
6. Upon successful completion the DUP will prompt to reboot system.
7. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
8. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
9. Once the flashing process is complete the system should power back up and boot to OS.


GnuPG Signature of Dell Update Package Instructions for ".sign" file:

Download
1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to your hard drive.

Installation
1. Import the Dell public key. (You only need to import once on your system.)
2. Verify the Dell Update Package by using its signature file.
3. Upon successful completion the DUP will prompt to reboot system.
4. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
5. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
6. Once the flashing process is complete the system should power back up and boot to OS.

Reboot will be required

Drivers help and tutorials