Artesyn 495W PSU (PN: 9338D, HDV6P, TH1CT,VKDD2) Firmware Package

Restart required AUTO INSTALLED This file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
This package provides the new firmware for power supplier and is supported on Artesyn 495W PSU (PN: 9338D,HDV6P,TH1CT,VKDD2).
Recommended

Find the best download for your system

Please enter your product details to view the latest driver information for your system

Search support

Enter your Dell Service Tag or model

Want to look up your product? Enter a product identifier. Show me how

This driver is not compatible

This driver is not applicable for the selected product. Choose another product to re-enter your product details for this driver or visit the Product Support page to view all drivers for a different product.

Find more updates. Use SupportAssist to find all the latest driver updates for your device.

Fixes & Enhancements

[For VKDD2]
- Initial Release

[For 9338D,HDV6P,TH1CT]
Fix.
- Fixed system power consumption in exceed fault reporting issue(JIT-56264).
- Fixed AC-lost issue by SEL reported(JIT63763).
- Fixed some of i2c commands bug.
- Fixed fan fault reporting issue.
- Correct the wrong fw revision reporting after re-flash the fw.

Enhancement.
- Improve power management while power cycling.
- Improve internal communication with error handling.
- Improve the control behavior during AC-Lost event.
- Improve dc-on control while AC is removed.
Read More

Version

00.1B.53, 00.1B.53

Release date

11 Jul 2017

Download Type

Firmware

Category

Power

Importance

Recommended
Dell Technologies recommends applying this update during your next scheduled update cycle. The update contains changes to maintain overall system health. It ensures that the system software remains current and compatible with other system modules (firmware, BIOS, drivers, and software) and may include other new features.
Available formats View Important Information

File Format: Update Package for MS Windows 64-Bit.
File Name: Power_Firmware_K58RJ_WN64_00.1B.53.EXE
File Size: 11.51 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages in native Microsoft Windows 64-bit format do not require that Microsoft WOW64 be installed on the Microsoft Windows Server.
To ensure the integrity of your download, please verify the checksum value.
MD5:
c51cc89838830d3aef9cbef2add7cb80
SHA1:
e27ef614214618ccdf695c79dab2dabfbf718a8b
SHA-256:
e41e047bb2d7918144297642d43d20fc46b7d4b13c2aa8a755b275c17a9a0357

File Format: A GnuPG file which contains a cryptographic signature
File Name: Power_Firmware_K58RJ_LN_00.1B.53.BIN.sign
File Size: 194 Bytes
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
The GnuPG signature for Red Hat Linux Update Package can be used to authenticate Dell's identity in the correlated Red Hat Linux Update Package.
To ensure the integrity of your download, please verify the checksum value.
MD5:
f5dfbcc119b5b7d58df89e58bc46814e
SHA1:
64bc577b5aa347946dc4479fd7edd11667fa25a5
SHA-256:
e02777a6a4b2a71d629cac75c1aaa31a4476efe71cad02ee0ccd6fe8684d4038

File Format: Update Package for MS Windows 32-Bit
File Name: Power_Firmware_K58RJ_WN32_00.1B.53.EXE
File Size: 6.89 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages (DUP) in Microsoft Windows 32bit format have been designed to run on Microsoft Windows 64bit Operating Systems. Dell Update Packages (DUP) in Microsoft Windows 64bit format will only run on Microsoft Windows 64bit Operating Systems. When selecting a device driver update be sure to select the one that is appropriate for your operating system.
To ensure the integrity of your download, please verify the checksum value.
MD5:
3c4761ca130a020a4c6ada4b4cda51a0
SHA1:
e8f65f678a9e891dfa288e9fa48350d48286a4f4
SHA-256:
d50e37057ab4cbd251ea5f4345431a05d5f8accd2f7a0e5500318924284bebce

File Format: Update Package for Red Hat Linux
File Name: Power_Firmware_K58RJ_LN_00.1B.53.BIN
File Size: 2.03 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages for Linux can be used as stand-alone applications that ensure that specific validation criteria are met, then apply an update.
Note: Update Packages for Linux are open source. See the Dell Update Packages for Linux Readme for details.
To ensure the integrity of your download, please verify the checksum value.
MD5:
cab8a6037e0100f1770a53071f650842
SHA1:
7a1d10d931607240f09f5fb9fcfbc5731608aca3
SHA-256:
acf119b50ff691bbd64640dd056a3e378b66ae7ff654d42b6fe2d0c7b030d335

By downloading, you accept the terms of the Dell Software License Agreement.

Additional details

Show All | Hide All
IMPORTANT:
- After a successful power supply firmware download, the managed system turns off for a duration ranging from three to ten minutes to continue updating the firmware. Once the firmware update is complete, the managed system reboots automatically.

CAUTION! Performing an AC power cycle or cold boot during a power supply firmware update, forces the power supply unit into an irrecoverable state and the managed system does not boot.
Emerson 495W PSU
PWR SPLY,495W,RDNT,13G,ART,V3
PWR SPLY,495W,RDNT,13G,ART,V4
PSU FIRMWARE UPDATE INSTRUCTIONS:

CAUTION: Performing an AC power cycle or cold boot during a power supply firmware update, forces the power supply unit (PSU) into an irrecoverable state and the managed system does not boot.

IMPORTANT:
After a successful power supply firmware download, the managed system turns off for a duration ranging from three to twenty minutes to continue updating the firmware. It is imperative not to interrupt/restart manually during this time. Update time can vary but should be approximately 10 minutes. Margin should be added to assure the Dell Update Package (DUP) is not interrupted (some DUPs may take up to 20 minutes). Once the firmware update is complete, the managed system reboots automatically.


Instructions for ".BIN" file:

Download
1. Click the Download Now link to download the file.
2. When the "File Download" window appears, click Save to save the file to your hard drive.

Installation
1. Read the release information presented by executing the ".BIN" file with "--version" command from the shell.
2. Download and install any prerequisites identified in the above step before proceeding.
3. Run the update by executing ".BIN" file from the shell.
4. Follow the remaining prompts to perform the update.
5. Upon successful completion the DUP will prompt to reboot system.
6. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
7. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
8. Once the flashing process is complete the system should power back up and boot to OS.

Instructions for ".EXE" file:

Download
1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to your hard drive.

Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.
6. Upon successful completion the DUP will prompt to reboot system.
7. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
8. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
9. Once the flashing process is complete the system should power back up and boot to OS.


GnuPG Signature of Dell Update Package Instructions for ".sign" file:

Download
1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to your hard drive.

Installation
1. Import the Dell public key. (You only need to import once on your system.)
2. Verify the Dell Update Package by using its signature file.
3. Upon successful completion the DUP will prompt to reboot system.
4. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
5. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
6. Once the flashing process is complete the system should power back up and boot to OS.