Liteon 1100W PSU (PN: Y3H8J, TFR9V, 9TMRF) Firmware Package

Restart required AUTO INSTALLED This file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
This package provides the new firmware for power supplier and is supported on Liteon 1100W PSU (PN: Y3H8J, TFR9V, 9TMRF).
Recommended

Find the best download for your system

Please enter your product details to view the latest driver information for your system

Search support

Enter your Dell Service Tag or model

Want to look up your product? Enter a product identifier. Show me how

This driver is not compatible

This driver is not applicable for the selected product. Choose another product to re-enter your product details for this driver or visit the Product Support page to view all drivers for a different product.

Find more updates. Use SupportAssist to find all the latest driver updates for your device.

Fixes & Enhancements

Fix:
- None.

Enhancement:
- Improve Hot-spare hardware control function.
Read More

Version

00.24.44, 00.24.44

Release date

30 Oct 2017

Download Type

Firmware

Category

Power

Importance

Recommended
Dell Technologies recommends applying this update during your next scheduled update cycle. The update contains changes to maintain overall system health. It ensures that the system software remains current and compatible with other system modules (firmware, BIOS, drivers, and software) and may include other new features.
Available formats View Important Information

File Format: Update Package for MS Windows 64-Bit.
File Name: Power_Firmware_K5DP6_WN64_00.24.44_01.EXE
File Size: 11.51 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages in native Microsoft Windows 64-bit format do not require that Microsoft WOW64 be installed on the Microsoft Windows Server.
To ensure the integrity of your download, please verify the checksum value.
MD5:
b3076646673de98a7d662f1c212c3cbf
SHA1:
6498ed4b209f1d5c89a45bf94c55150bbbab1469
SHA-256:
01119c45a65a230b316c82c4d65d53e6366ad3720db5fc8fc12d401ce6e47ed8

File Format: A GnuPG file which contains a cryptographic signature
File Name: Power_Firmware_K5DP6_LN_00.24.44_01.BIN.sign
File Size: 194 Bytes
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
The GnuPG signature for Red Hat Linux Update Package can be used to authenticate Dell's identity in the correlated Red Hat Linux Update Package.
To ensure the integrity of your download, please verify the checksum value.
MD5:
0c9f417b3fb0a20514ecdd9d1e52af25
SHA1:
d056eaf69b52dd9731a6939c4eacacc1634e2fc8
SHA-256:
6c36f237a0f32cdfaad1669edf66439de053e0243a36a00b42808a0f731d5da0

File Format: Update Package for MS Windows 32-Bit
File Name: Power_Firmware_K5DP6_WN32_00.24.44_01.EXE
File Size: 6.9 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages (DUP) in Microsoft Windows 32bit format have been designed to run on Microsoft Windows 64bit Operating Systems. Dell Update Packages (DUP) in Microsoft Windows 64bit format will only run on Microsoft Windows 64bit Operating Systems. When selecting a device driver update be sure to select the one that is appropriate for your operating system.
To ensure the integrity of your download, please verify the checksum value.
MD5:
56e80a55dfadf52f521fdde542ee07d0
SHA1:
40ee7b7f34cb379eebd63256bc283dfec4489217
SHA-256:
3bb9d5e3fc30d5507ea8b4ee81a7cab7f983185ba694c62392f244e682b956ef

File Format: Update Package for Red Hat Linux
File Name: Power_Firmware_K5DP6_LN_00.24.44_01.BIN
File Size: 2.04 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages for Linux can be used as stand-alone applications that ensure that specific validation criteria are met, then apply an update.
Note: Update Packages for Linux are open source. See the Dell Update Packages for Linux Readme for details.
To ensure the integrity of your download, please verify the checksum value.
MD5:
e211f65eb97b3995a8bbc50e9b10e890
SHA1:
9f16a75f70acfd7446b58330086ca75b96b742da
SHA-256:
0c485fad3e4a35292ef815de785826cde6f89923b9829e8612852066d54119bf

By downloading, you accept the terms of the Dell Software License Agreement.

Additional details

Show All | Hide All
IMPORTANT:
- After a successful power supply firmware download, the managed system turns off for a duration ranging from three to ten minutes to continue updating the firmware. Once the firmware update is complete, the managed system reboots automatically.

CAUTION! Performing an AC power cycle or cold boot during a power supply firmware update, forces the power supply unit into an irrecoverable state and the managed system does not boot.
LiteOn 1100W PSU V3
PWR SPLY,1100,RDNT,13G,LITEON,2
PWR SPLY,1100,RDNT,13G,LITEON,3
PWR SPLY,1100W,RDNT,13G,LITEON
PSU FIRMWARE UPDATE INSTRUCTIONS:

CAUTION: Performing an AC power cycle or cold boot during a power supply firmware update, forces the power supply unit (PSU) into an irrecoverable state and the managed system does not boot.

IMPORTANT:
After a successful power supply firmware download, the managed system turns off for a duration ranging from three to twenty minutes to continue updating the firmware. It is imperative not to interrupt/restart manually during this time. Update time can vary but should be approximately 10 minutes. Margin should be added to assure the Dell Update Package (DUP) is not interrupted (some DUPs may take up to 20 minutes). Once the firmware update is complete, the managed system reboots automatically.


Instructions for ".BIN" file:

Download
1. Click the Download Now link to download the file.
2. When the "File Download" window appears, click Save to save the file to your hard drive.

Installation
1. Read the release information presented by executing the ".BIN" file with "--version" command from the shell.
2. Download and install any prerequisites identified in the above step before proceeding.
3. Run the update by executing ".BIN" file from the shell.
4. Follow the remaining prompts to perform the update.
5. Upon successful completion the DUP will prompt to reboot system.
6. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
7. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
8. Once the flashing process is complete the system should power back up and boot to OS.

Instructions for ".EXE" file:

Download
1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to your hard drive.

Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.
6. Upon successful completion the DUP will prompt to reboot system.
7. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
8. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
9. Once the flashing process is complete the system should power back up and boot to OS.


GnuPG Signature of Dell Update Package Instructions for ".sign" file:

Download
1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to your hard drive.

Installation
1. Import the Dell public key. (You only need to import once on your system.)
2. Verify the Dell Update Package by using its signature file.
3. Upon successful completion the DUP will prompt to reboot system.
4. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
5. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
6. Once the flashing process is complete the system should power back up and boot to OS.

Drivers help and tutorials