Intel DL58 for model number(s) SSDSC2KB240G7R, SSDSC2KB480G7R, SSDSC2KB960G7R, SSDSC2KB019T7R, SSDSC2KB038T7R, SSDSC2KB076T7R, SSDSC2KG240G7R, SSDSC2KG480G7R, SSDSC2KG960G7R, SSDSC2KG019T7R and SSDSC2KG038T7R.

AUTO INSTALLED This file was automatically installed as part of a recent update. If you are experiencing any issues, you can manually download and reinstall.
This release contains firmware version DL567for Intel drives. Vendor model numbers SSDSC2KB240G7R, SSDSC2KB480G7R, SSDSC2KB960G7R, SSDSC2KB019T7R, SSDSC2KB038T7R, SSDSC2KB076T7R, SSDSC2KG240G7R, SSDSC2KG480G7R, SSDSC2KG960G7R, SSDSC2KG019T7R and SSDSC2KG038T7R.
Recommended

Find the best download for your system

Please enter your product details to view the latest driver information for your system

Search support

Enter your Dell Service Tag or model

Want to look up your product? Enter a product identifier. Show me how

This driver is not compatible

This driver is not applicable for the selected product. Choose another product to re-enter your product details for this driver or visit the Product Support page to view all drivers for a different product.

Find more updates. Use SupportAssist to find all the latest driver updates for your device.

Fixes & Enhancements

Fixes:
-Addresses rare case where drive may return stale data during SYNC Escape occurrence while an acknowledged write is pending commit to NAND
-NAND retention issue that can occur if power is removed from the drive for 3+months
- Addresses 1-5 second latency during large tranfer size operations
- Addresses drive assert condition when processing large transfers
- Addresses case where drive may send a R_ERR primitive instead of SDB FIS after finishing the last DATA FIS of a Write FPDMAQ command
Read More

Version

DL58, A00

Release date

04 Jun 2018

Download Type

Firmware

Category

Storage

Importance

Recommended
Dell Technologies recommends applying this update during your next scheduled update cycle. The update contains changes to maintain overall system health. It ensures that the system software remains current and compatible with other system modules (firmware, BIOS, drivers, and software) and may include other new features.
Available formats View Important Information

File Format: Update Package for MS Windows 64-Bit.
File Name: Serial-ATA_Firmware_KRP53_WN64_DL58_A00_01.EXE
File Size: 9.93 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages in native Microsoft Windows 64-bit format do not require that Microsoft WOW64 be installed on the Microsoft Windows Server.
To ensure the integrity of your download, please verify the checksum value.
MD5:
1cc1970c3c2a0ce74d6a450a4064f719
SHA1:
2d570494dd59be8265377e6077e908b7f67a9c2e
SHA-256:
cddd9011026a282ee4c88b63f65050bbcecaccae9bbc524ecc17c2051972cd3b

File Format: A GnuPG file which contains a cryptographic signature
File Name: Serial-ATA_Firmware_KRP53_LN_DL58_A00.BIN.sign
File Size: 226 Bytes
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
The GnuPG signature for Red Hat Linux Update Package can be used to authenticate Dell's identity in the correlated Red Hat Linux Update Package.
To ensure the integrity of your download, please verify the checksum value.
MD5:
8406437d4327ffcd6bfa34d2f640842b
SHA1:
def1501e9bde38c097afebfae8984fccc77de333
SHA-256:
96768ed0b09fb3508f9b966afcc1aecdb285a13dda5340b20c7ff1c0693003d6

File Format: Update Package for MS Windows 32-Bit
File Name: Serial-ATA_Firmware_KRP53_WN32_DL58_A00_01.EXE
File Size: 8.74 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages (DUP) in Microsoft Windows 32bit format have been designed to run on Microsoft Windows 64bit Operating Systems. Dell Update Packages (DUP) in Microsoft Windows 64bit format will only run on Microsoft Windows 64bit Operating Systems. When selecting a device driver update be sure to select the one that is appropriate for your operating system.
To ensure the integrity of your download, please verify the checksum value.
MD5:
38b34aa2f0a06e5f03d5260d8f4bcfba
SHA1:
f1bac9a12e3a0e5c3c063582e3af8541398ca7ca
SHA-256:
10f721b7f8ab8809258f47190feb491ec053516f687f8a428a4a1093a1b240bc

File Format: Update Package for Red Hat Linux
File Name: Serial-ATA_Firmware_KRP53_LN_DL58_A00.BIN
File Size: 6.01 MB
This is a large file. Depending on your connection speed, it may take some time to download.
Format Description:
Dell Update Packages for Linux can be used as stand-alone applications that ensure that specific validation criteria are met, then apply an update.
Note: Update Packages for Linux are open source. See the Dell Update Packages for Linux Readme for details.
To ensure the integrity of your download, please verify the checksum value.
MD5:
4e26647a781e51da2e99fd6b44ad3358
SHA1:
552af6017a729b96ca0df7319b6df45a2da76ad9
SHA-256:
d91fbf990ceb7dc620bd13e35af19247419193b5437d9eac6493168b1650c1af

By downloading, you accept the terms of the Dell Software License Agreement.

Additional details

Show All | Hide All
This update will not run if any of the following conditions exist
1. Any Virtual Disk that is not optimal.
2. A RAID container that is performing a Background Initialization or Consistency Check.
3. A Rebuild, Resync, or copyback function is taking place.
4. A RAID set that is Partially Degraded or in a Degraded state.

This update will run on drives remaining in a RAID set that is in a Offline state.

There is an architectural constraint with Dell DUP HDD firmware update utility, related to system memory utilization, which is typically encountered on systems with minimal system memory, memory-intensive configurations, multiple RAID controllers, or memory-intensive applications. This issue is typically reported as - The operation was not successful because the device buffer write has failed. And will result in an aborted attempt to update firmware on the identified HDD. Error codes associated with this failure mode include 8009 and 8017. Once an error is detected, the update session is aborted. There is no data integrity or data availability risk associated with this issue. Subsequent attempts to update the HDD firmware may succeed, particularly if system resources are freed up.
Novell SuSE Linux ES 11
Windows Server 2008 x64
Suse Linux ES 10
Windows Server 2012
Not Applicable
Red Hat® Ent Linux 5.2
Red Hat® Enterprise Linux 6
Red Hat® Enterprise Linux 7
Red Hat® Ent Linux 5
SUSE Linux ES 12
Windows Server 2012 R2
Windows Server 2008 x86
Windows Server 2008 R2
Windows Server 2016
Intel Youngsville S4500 RI 1.92TB SSD SATA6 2.5 512e ISE Model Number: SSDSC2KB019T7R Regulatory Model Number: SSDSC2KB019T7 Vendor PN: SSDSC2KB019T7R
Intel Youngsville S4500 RI 240GB SSD SATA6 2.5 512e ISE Model Number: SSDSC2KB240G7R Regulatory Model Number: SSDSC2KB240G7 Vendor PN: SSDSC2KB240G7R
Intel Youngsville S4500 RI 3.84TB SSD SATA6 2.5 512e ISE Model Number: SSDSC2KB038T7R Regulatory Model Number: SSDSC2KB038T7 Vendor PN: SSDSC2KB038T7R
Intel Youngsville S4500 RI 480GB SSD SATA6 2.5 512e ISE Model Number: SSDSC2KB480G7R Regulatory Model Number: SSDSC2KB480G7 Vendor PN: SSDSC2KB480G7R
Intel Youngsville S4500 RI 960GB SSD SATA6 2.5 512e ISE Model Number: SSDSC2KB960G7R Regulatory Model Number: SSDSC2KB960G7 Vendor PN: SSDSC2KB960G7R
Intel Youngsville S4600 MU 1.92TB SSD SATA6 2.5 512e ISE Model Number: SSDSC2KG019T7R Regulatory Model Number: SSDSC2KG019T7 Vendor PN: SSDSC2KG019T7R
Intel Youngsville S4600 MU 240GB SSD SATA6 2.5 512e ISE Model Number: SSDSC2KG240G7R Regulatory Model Number: SSDSC2KG240G7 Vendor PN: SSDSC2KG240G7R
Intel Youngsville S4600 MU 480GB SSD SATA6 2.5 512e ISE Model Number: SSDSC2KG480G7R Regulatory Model Number: SSDSC2KG480G7 Vendor PN: SSDSC2KG480G7R
Intel Youngsville S4600 MU 960GB SSD SATA6 2.5 512e ISE Model Number: SSDSC2KG960G7R Regulatory Model Number: SSDSC2KG960G7 Vendor PN: SSDSC2KG960G7R
1. Click the 'Download Now' link to download the file.
2. When the File Download window appears, click 'Save' to save the file to your hard drive.

Installation

1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.

Drivers help and tutorials