Dell PowerVault MD 32/36 Series Storage Controller Firmware and NVSRAM firmware version 08.20.21.61

需要重新啟動 已自動安裝 此檔案會在最近更新時自動安裝。如果您遇到任何問題,可以手動下載並重新安裝。
此頁面的內容可能經過電腦自動翻譯。若要提供意見回饋,請填寫頁面底部的表單。
Dell PowerVault MD32/MD36 Series Storage Array, including firmware for MD12x0 attached to MD32/MD36 series array.
建議

為您的系統尋找最適合的下載項目

請輸入產品的詳細資料以檢視系統的最新驅動程式資訊

搜尋支援

輸入您的 Dell 產品服務編號或型號

想要尋找您的產品嗎?請輸入產品識別碼。 告訴我怎麼做

此驅動程式不相容

此驅動程式不適用於選取的產品。請選擇其他產品,以重新輸入適用於此驅動程式的產品詳細資料,或前往產品支援頁面,檢視其他產品的所有驅動程式。

尋找更多更新。使用 SupportAssist 為您的裝置尋找所有最新的驅動程式更新。

修復及強化

Fixes:
Enclosure ID changing to 48 on extension arrays
Last character missing from service tag on dense array when using SymbolSDK
Controller reboot during online drive firmware update might cause data inconsistency
During heavy I/O, Online Drive Firmware Update might cause dropped writes
Controller reboot when disabling Data Assurance on a Thin Volume with SSD Cache enabled
In a clustered environment, with a large number of volumes being reserved per host, an additional controller reboot occurred during online RAID controller download
Asynch replication placed offline during volume expansion and volume ownership change
XCOPY on thin volume hangs and controller reboots during thin volume expansion
Controller reboot caused by repeated bus reset or target reset from hosts

Enhancements:
None
閱讀更多

繁體中文版

08.20.21.61, A17

發佈日期

25 1月 2017

下載類型

韌體

類別

儲存控制器

重要性

建議
Dell Technologies 建議您在下一個排定的更新週期套用此更新。此更新包含的變更可維持整體的系統健全狀況。此更新可確保系統軟體保持在最新狀態並與其他系統模組 (韌體、BIOS、驅動程式及軟體) 相容,並且可能包含其他新功能。
可用的格式 檢視重要資訊

檔案格式: 影像的基礎驅動程式
檔案名稱: PowerVault_MD32_MD36_Series_Firmware_08_20_21_61.zip
檔案大小: 301.51 MB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
為了確保下載的完整性,請驗證總和檢查值。
MD5:
14ab2813e92d98ad23e278e75335f7a7
SHA1:
622aee0dc8dfb0e4f7003f2326258ebf0c0bf4a9
SHA-256:
9dd3628390663ebf92900abf074803051a0aa0a2c392c076ba3a1ec3bafe3c5c

當您開始下載,即表示您接受 Dell 軟體授權協定 (英文版) 的條款。

其他詳細資料

顯示全部 | 隱藏全部
*** ATTENTION ***
If your PowerVault MD32xx/MD36xx series storage array is currently running a firmware version lower than 07.75.28.60, you cannot directly install the RAID controller firmware version 08.20.21.61 included in this release.

Instead, you must first install the bridge firmware version 07.75.28.60. After the bridge firmware is successfully installed, you can then install RAID controller firmware 08.20.21.61
Novell SuSE Linux ES 11
Red Hat® Enterprise Linux 6
Red Hat® Enterprise Linux 7
Windows Storage Server 2012 R2
SUSE Linux ES 12
Windows Server 2012 R2
Windows 7, 64-bit
Windows 8, 64-bit
Windows 8.1, 64-bit
Windows Server 2008 R2
Windows Server 2016
Windows 10, 64-bit
VMware ESXi 5.1
VMware ESXi 5.5
VMware ESXi 6.0
VMware ESXi 6.5
MD3 Series Controller Firmware Updates
*** WARNING ***
If you have a single controller PowerVault MD32/MD36 series storage array you must stop all I/O operations before starting the RAID controller firmware upgrade.

Specifically, follow these steps:

1. ***IMPORTANT*** Install the latest Dell PowerVault MD Storage Manager (MDSM) software from the Resource DVD. Must be at least version 6.4.0.4 or higher.

NOTE: It is recommended that you install all the latest updates available at www.dell.com/support

2. Extract the following files from the Bridge_Firmware_07_75_28_60.zip archive:
* Bridge_Firmware_07_75_28_60.dlp

3. Download and activate RAID controller bridge firmware version 07.75.28.60 (contained in the Bridge_Firmware_07_75_28_60.dlp file)

4. Once the bridge firmware installation is successfully completed, wait at least 30 minutes to allow the attached hosts to re-discover the storage array.

5. Download and activate the RAID controller firmware version 08.20.21.60 together with the NVSRAM configuration file version using the Dell PowerVault MD Storage Manager for your corresponding array type.

驅動程式說明與教學課程