Toshiba SAS MK1001TRKB and MK2001TRKB firmware version DCAD

已自動安裝 此檔案會在最近更新時自動安裝。如果您遇到任何問題,可以手動下載並重新安裝。
此頁面的內容可能經過電腦自動翻譯。若要提供意見回饋,請填寫頁面底部的表單。
This release contains firmware version DCAD for Toshiba SAS (7.2K rpm 3.5 SAS) 2TB Hard Drives. Dell. Vendor model number MK1001TRKB and MK2001TRKB.
建議

為您的系統尋找最適合的下載項目

請輸入產品的詳細資料以檢視系統的最新驅動程式資訊

搜尋支援

輸入您的 Dell 產品服務編號或型號

想要尋找您的產品嗎?請輸入產品識別碼。 告訴我怎麼做

此驅動程式不相容

此驅動程式不適用於選取的產品。請選擇其他產品,以重新輸入適用於此驅動程式的產品詳細資料,或前往產品支援頁面,檢視其他產品的所有驅動程式。

尋找更多更新。使用 SupportAssist 為您的裝置尋找所有最新的驅動程式更新。

修復及強化

Fixes:
Resolved issue to comply with Persistent Reservation command
Resolved rare issue in mutli-initator enironment that could cause loss of IT_NEXUS

Enhancements:
N/A
閱讀更多

繁體中文版

DCAD, A03

發佈日期

03 5月 2013

下載類型

韌體

類別

SAS 硬碟

重要性

建議
Dell Technologies 建議您在下一個排定的更新週期套用此更新。此更新包含的變更可維持整體的系統健全狀況。此更新可確保系統軟體保持在最新狀態並與其他系統模組 (韌體、BIOS、驅動程式及軟體) 相容,並且可能包含其他新功能。
可用的格式 檢視重要資訊

檔案格式: 適用於 MS Windows (32 位元) 的更新套件
檔案名稱: SAS-Drive_Firmware_GJ0KV_WN32_DCAD_A03.EXE
檔案大小: 11.05 MB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
Microsoft Windows 32 位元格式的 Dell 更新套件 (DUP) 經過精心設計,可在 Microsoft Windows 64 位元作業系統上執行。Microsoft Windows 64 位元格式的 Dell 更新套件 (DUP) 只能在 Microsoft Windows 64 位元作業系統上執行。選擇裝置驅動程式更新時,請務必選擇適用您作業系統的更新。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
9dc2f5989bd60efcc60b965a91776485
SHA1:
15f3950e902c39dbf894d62c18a18259d9fbd47e
SHA-256:
9e980b9ee2bbc8247c1b07e69b388574bedcd2845400db3f1fe9173a5a848cd5

檔案格式: 包含密碼編譯簽章的 GnuPG 檔案
檔案名稱: SAS-Drive_Firmware_GJ0KV_LN_DCAD_A03.BIN.sign
檔案大小: 189 Bytes
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
您可以使用適用於 Red Hat Linux 更新套件的 GnuPG 簽章,在相關聯的 Red Hat Linux 更新套件中驗證 Dell 的身分。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
f05bcb02f95189eb26d3ef55eddfe987
SHA1:
c11f5b8cd4c348e65ddf819ed5c706a05757b755
SHA-256:
802dd6c6f5981268dac2c088aa86110f5491c45a3bc321fbcb8d2b3289f353a7

檔案格式: 適用於 Red Hat Linux 的更新套件
檔案名稱: SAS-Drive_Firmware_GJ0KV_LN_DCAD_A03.BIN
檔案大小: 9.79 MB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
適用於 Linux 的 Dell 更新套件可做為獨立的應用程式,確保符合特定的驗證條件,然後套用更新。
注意:適用於 Linux 的更新套件為開放原始碼套件。請參閱適用於 Linux 的 Dell 更新套件的「讀我」檔案,瞭解詳情。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
883090c7d64d403145c829e5dddae62b
SHA1:
d4a3d74d7d6d62a7b7477179e4039db9a444435d
SHA-256:
44a56787ae98ec6a1490afc163d7b3318fb9d8d8b9d7623a38a4a2dae7f9881d

當您開始下載,即表示您接受 Dell 軟體授權協定 (英文版) 的條款。

其他詳細資料

顯示全部 | 隱藏全部
This update will not run if any of the following conditions exist
1. Any Virtual Disk that is not optimal.
2. A RAID container that is performing a Background Initialization or Consistency Check.
3. A Rebuild, Resync, or copyback function is taking place.
4. A RAID set that is Partially Degraded or in a Degraded state.

This update will run on drives remaining in a RAID set that is in a Offline state.

There is an architectural constraint with Dell DUP HDD firmware update utility, related to system memory utilization, which is typically encountered on systems with minimal system memory, memory-intensive configurations, multiple RAID controllers, or memory-intensive applications. This issue is typically reported as - The operation was not successful because the device buffer write has failed. And will result in an aborted attempt to update firmware on the identified HDD. Error codes associated with this failure mode include 8009 and 8017. Once an error is detected, the update session is aborted. There is no data integrity or data availability risk associated with this issue. Subsequent attempts to update the HDD firmware may succeed, particularly if system resources are freed up.
Novell SuSE Linux ES 11
Windows Server 2008 x64
Red Hat® Enterprise Linux 4.5
Red Hat® Enterprise Linux 4.6
SuSE Linux ES 9
Suse Linux ES 9
Suse Linux ES 10
Red Hat® Enterprise Linux 4.5
Windows Server 2012
Red Hat® Enterprise Linux 4.7
Red Hat® Enterprise Linux 5.2
Red Hat® Enterprise Linux 6
Red Hat® Enterprise Linux 5
Novell SuSE Linux ES 10
Windows Server 2008 x86
Windows Server 2003
Windows Server 2008 R2
Windows Server 2003 x64
TOSHIBA MK1001TRKB Series SAS 7.2K RPM 3.5" 1TB
TOSHIBA MK2001TRKB Series SAS 7.2K RPM 3.5" 2TB
1. Click the "Download Now" link to download the file.
2. When the File Download window appears, click "Save" to save the file to your hard drive.

Installation

1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.

驅動程式說明與教學課程