Hitachi NL SAS HUS723020ALS640 and HUS723030ALS640 firmware version M2D4.
已自動安裝 此檔案會在最近更新時自動安裝。如果您遇到任何問題,可以手動下載並重新安裝。此頁面的內容可能經過電腦自動翻譯。若要提供意見回饋,請填寫頁面底部的表單。
This release contains firmware version M2D4 for Hitachi NL SAS (7.2K rpm 3.5 SAS) 2TB and 3TB Hard Drives. Dell. Vendor model numbers HUS723020ALS640 and HUS723030ALS640.
建議
尋找更多更新。使用 SupportAssist 為您的裝置尋找所有最新的驅動程式更新。
修復及強化
Resolves issue with false drive failures. Reseat drive and flash using M2D4 prior to replacing drive.
Resolves issue with incorrect sense code when resuming from idle
Improves sequential Read / Write performance
Improved drive error handling
Improved drive long term reliability
閱讀更多Resolves issue with incorrect sense code when resuming from idle
Improves sequential Read / Write performance
Improved drive error handling
Improved drive long term reliability
繁體中文版
M2D4, A02
發佈日期
31 7月 2012
下載類型
韌體
類別
SAS 硬碟
重要性
緊急Dell Technologies 強烈建議儘快套用此重要更新。此更新包含的重大錯誤修正和變更,可改善 Dell 系統功能、可靠性及穩定性。其也可能包含安全性修正和其他增強功能。
檔案格式: 適用於 MS Windows (32 位元) 的更新套件
檔案名稱: SAS-Drive_Firmware_6C17T_WN32_M2D4_A02.EXE
檔案大小: 6.05 MB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
Microsoft Windows 32 位元格式的 Dell 更新套件 (DUP) 經過精心設計,可在 Microsoft Windows 64 位元作業系統上執行。Microsoft Windows 64 位元格式的 Dell 更新套件 (DUP) 只能在 Microsoft Windows 64 位元作業系統上執行。選擇裝置驅動程式更新時,請務必選擇適用您作業系統的更新。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
2eba1467f995b63a1314f23cb1d75f48
SHA1:
33a480475b7c1ce6a4b89de44e489f99b153f33d
SHA-256:
15105a6f30329ed5861947eac96aced7913facdde0ca0106f5217b6748cef5f5
檔案格式: 包含密碼編譯簽章的 GnuPG 檔案
檔案名稱: SAS-Drive_Firmware_6C17T_LN32_M2D4_A02.BIN.sign
檔案大小: 194 Bytes
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
您可以使用適用於 Red Hat Linux 更新套件的 GnuPG 簽章,在相關聯的 Red Hat Linux 更新套件中驗證 Dell 的身分。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
bd4a43243c22eda3d6486390fdd09808
SHA1:
2881faa69f7fb9e0bddfde4a4510de1d65159dc6
SHA-256:
288dca7ef9b46915156b7950c48ac2604ca42c8fa7c2508917efd34e5d28f629
檔案格式: 適用於 Red Hat Linux 的更新套件
檔案名稱: SAS-Drive_Firmware_6C17T_LN32_M2D4_A02.BIN
檔案大小: 4.07 MB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
適用於 Linux 的 Dell 更新套件可做為獨立的應用程式,確保符合特定的驗證條件,然後套用更新。
注意:適用於 Linux 的更新套件為開放原始碼套件。請參閱適用於 Linux 的 Dell 更新套件的「讀我」檔案,瞭解詳情。
注意:適用於 Linux 的更新套件為開放原始碼套件。請參閱適用於 Linux 的 Dell 更新套件的「讀我」檔案,瞭解詳情。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
8ae0c4626181ae8d8de6a9de5ad0b415
SHA1:
f1fdb9f3582bbeffe16afddb9c58e1e8cc7dfae3
SHA-256:
e6a8bbbcd2f62963e5473b99743e4109ced1fbee355e579bcd2a31d201b2a12e
當您開始下載,即表示您接受 Dell 軟體授權協定 (英文版) 的條款。
This update will not run if any of the following conditions exist
1. Any Virtual Disk that is not optimal.
2. A RAID container that is performing a Background Initialization or Consistency Check.
3. A Rebuild, Resync, or copyback function is taking place.
4. A RAID set that is Partially Degraded or in a Degraded state.
This update will run on drives remaining in a RAID set that is in a Offline state.
There is an architectural constraint with Dell DUP HDD firmware update utility, related to system memory utilization, which is typically encountered on systems with minimal system memory, memory-intensive configurations, multiple RAID controllers, or memory-intensive applications. This issue is typically reported as - The operation was not successful because the device buffer write has failed. And will result in an aborted attempt to update firmware on the identified HDD. Error codes associated with this failure mode include 8009 and 8017. Once an error is detected, the update session is aborted. There is no data integrity or data availability risk associated with this issue. Subsequent attempts to update the HDD firmware may succeed, particularly if system resources are freed up.
1. Any Virtual Disk that is not optimal.
2. A RAID container that is performing a Background Initialization or Consistency Check.
3. A Rebuild, Resync, or copyback function is taking place.
4. A RAID set that is Partially Degraded or in a Degraded state.
This update will run on drives remaining in a RAID set that is in a Offline state.
There is an architectural constraint with Dell DUP HDD firmware update utility, related to system memory utilization, which is typically encountered on systems with minimal system memory, memory-intensive configurations, multiple RAID controllers, or memory-intensive applications. This issue is typically reported as - The operation was not successful because the device buffer write has failed. And will result in an aborted attempt to update firmware on the identified HDD. Error codes associated with this failure mode include 8009 and 8017. Once an error is detected, the update session is aborted. There is no data integrity or data availability risk associated with this issue. Subsequent attempts to update the HDD firmware may succeed, particularly if system resources are freed up.
Novell SuSE Linux ES 11
Windows Server 2008 x64
Red Hat® Enterprise Linux 4.5
Red Hat® Enterprise Linux 4.6
SuSE Linux ES 9
Suse Linux ES 9
Suse Linux ES 10
Red Hat® Enterprise Linux 4.5
Red Hat® Enterprise Linux 4.7
Red Hat® Enterprise Linux 5.2
Red Hat® Enterprise Linux 6
Red Hat® Enterprise Linux 5
Novell SuSE Linux ES 10
Windows Server 2008 x86
Windows Server 2003
Windows Server 2008 R2
Windows Server 2003 x64
HITACHI Ultrastar 7K3000 2TB SAS 7.2K RPM
HITACHI Ultrastar 7K3000 3TB SAS 7.2K RPM
Dell Update Package Instructions:
Download
1. Click the "Download Now" link to download the file.
2. When the File Download window appears, click "Save" to save the file to your hard drive.
Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.
Download
1. Click the "Download Now" link to download the file.
2. When the File Download window appears, click "Save" to save the file to your hard drive.
Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.