Dell SAS 6/iR Integrated, v.00.25.47.00.06.22.03.00 , A04

需要重新啟動 已自動安裝 此檔案會在最近更新時自動安裝。如果您遇到任何問題,可以手動下載並重新安裝。
此頁面的內容可能經過電腦自動翻譯。若要提供意見回饋,請填寫頁面底部的表單。
Dell Sas6/iR Integrated Firmware Release; Package Version: 00.25.47.00.06.22.03.00
建議

為您的系統尋找最適合的下載項目

請輸入產品的詳細資料以檢視系統的最新驅動程式資訊

搜尋支援

輸入您的 Dell 產品服務編號或型號

想要尋找您的產品嗎?請輸入產品識別碼。 告訴我怎麼做

此驅動程式不相容

此驅動程式不適用於選取的產品。請選擇其他產品,以重新輸入適用於此驅動程式的產品詳細資料,或前往產品支援頁面,檢視其他產品的所有驅動程式。

尋找更多更新。使用 SupportAssist 為您的裝置尋找所有最新的驅動程式更新。

修復及強化

BIOS - 06.22.03.00
NEW FUNCTIONALITY: None.
DEFECT FIXES:
-Implements a change to allow some RAID1 volumes created with earlier
SAS 6/iR FW revisions to be migrated to controllers with this FW revision.
- Implements a change to order the controller list based on defined
controller type instead of static chip-based references
- Updates verify functionality to allow user to escape once
Reassign All has been selected and drive is no longer responding.
- Removes rescan for devices on any keystroke in view array screen.
Rescan will now only be performed on Alt+N keystroke.


FIRMWARE - 00.25.47.00
NEW FUNCTIONALITY:
- Modifies coercion of RAID volumes to align with PERC. This facilitates
migration of SAS6 RAID volumes to PERC6.
DEFECT FIXES:
-Implements a change to allow some RAID1 volumes created with earlier
SAS 6/iR FW Revisions to be migrated controllers with this FW revision or later.
-Improves robustness in handling Task Management events during heavy IO
-Implements a change to correct an issue with initialization of interposer
attached SATA drives where link to the drive could be left in a state where
it was possible that I/Os could be timed out and have to be retried by
the host.
閱讀更多

繁體中文版

00.25.47.00.06.22.03.00, A04

發佈日期

06 12月 2011

下載類型

韌體

類別

SAS RAID

重要性

建議
Dell Technologies 建議您在下一個排定的更新週期套用此更新。此更新包含的變更可維持整體的系統健全狀況。此更新可確保系統軟體保持在最新狀態並與其他系統模組 (韌體、BIOS、驅動程式及軟體) 相容,並且可能包含其他新功能。
可用的格式 檢視重要資訊

檔案格式: 適用於 MS Windows (32 位元) 的更新套件
檔案名稱: SAS-RAID_Firmware_C1NFP_WN32_00.25.47.00.06.22.03.00_A04.EXE
檔案大小: 5.58 MB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
Microsoft Windows 32 位元格式的 Dell 更新套件 (DUP) 經過精心設計,可在 Microsoft Windows 64 位元作業系統上執行。Microsoft Windows 64 位元格式的 Dell 更新套件 (DUP) 只能在 Microsoft Windows 64 位元作業系統上執行。選擇裝置驅動程式更新時,請務必選擇適用您作業系統的更新。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
f5df4cb10828d547803de695a7591b71
SHA1:
38398b2ac0146a3e9985a64e96c0d6cb7594eda2
SHA-256:
不適用

檔案格式: 包含密碼編譯簽章的 GnuPG 檔案
檔案名稱: SAS-RAID_Firmware_C1NFP_LN32_00.25.47.00.06.22.03.00_A04.BIN.sign
檔案大小: 194 Bytes
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
您可以使用適用於 Red Hat Linux 更新套件的 GnuPG 簽章,在相關聯的 Red Hat Linux 更新套件中驗證 Dell 的身分。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
54fa186cdaec2d62f69b5881f930d161
SHA1:
af1465e56582fbb4b6d506d2a1c5331038802a6f
SHA-256:
不適用

檔案格式: ZipPack 外接
檔案名稱: DELL_SAS-6-IR-INTEGRATED_A04_R197383.exe
檔案大小: 563.29 KB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
此檔案內含已壓縮的檔案集。將檔案下載到硬碟上的資料夾,然後執行 (按兩下) 以解壓縮該檔案集。請依照指示完成安裝。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
8fb08900f2e308781d24b8b693e245d8
SHA1:
550c52aaa10e5f811894ae919f9bef3cbb34bebb
SHA-256:
4c3347826cd28339eafec650f1b7f1b26dfe9f5d9fe1b79d8f5ce98ac9c6154f

檔案格式: 外部版本資訊
檔案名稱: R197383.txt
檔案大小: 7.23 KB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
此檔案格式內含純文字,可使用標準文字編輯器予以檢視。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
4b11813d93d89a8fe4b925773e0581a2
SHA1:
不適用
SHA-256:
不適用

檔案格式: 適用於 Red Hat Linux 的更新套件
檔案名稱: SAS-RAID_Firmware_C1NFP_LN32_00.25.47.00.06.22.03.00_A04.BIN
檔案大小: 3.66 MB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
適用於 Linux 的 Dell 更新套件可做為獨立的應用程式,確保符合特定的驗證條件,然後套用更新。
注意:適用於 Linux 的更新套件為開放原始碼套件。請參閱適用於 Linux 的 Dell 更新套件的「讀我」檔案,瞭解詳情。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
8c7dcae3da0503f4ccec5fd2e50d6808
SHA1:
f8d4fa248bf9745a488670e26a18a73afcc770a8
SHA-256:
不適用

當您開始下載,即表示您接受 Dell 軟體授權協定 (英文版) 的條款。

其他詳細資料

顯示全部 | 隱藏全部
- When viewing SATA physical disk properties from Ctrl-C or other
management applications, Vendor Identification must be translated
as "ATA" followed by blanks. Please see SATA translation
specification, revision 5, pages 24-25 for more details.

- When multiple logical disks are configured on the SAS 6/iR and when viewing the logical disks from RAID Properties of the Ctrl-C BIOS utility, the order in which the logical disks are displayed may be reversed from the order in which they are created. This has no effect on the adapter functionality or boot order of the logical disks.

- When adding a SAS 6/iR controller to a system, either by physically
adding an adapter or by enabling the integrated SAS controller in
the system BIOS, the new controller may need to be added to the
controller boot order in the SAS 6/iR BIOS configuration Utility.
At POST, hit CTRL-C to enter the utility and verify or modify the
controller boot order.

- Migration of RAID Volumes from SAS 6/iR controllers to PERC6 controllers
is supported only for volumes originally created on SAS 6/iR controllers
running FW revision 00.25.47.00 or later.

- This version of firmware will not ensure complete compatibility with an
older version of the management application.
OpenManage 5.5 or greater is recommended.

- It is recommended that the customer upgrade the management application
and device driver to the latest version available from Dell at the time of
installation of this firmware.

- Before updating the SAS controller firmware using the DUP package in a Linux system, it is necessary to upgrade the SAS controller driver. Executing the SAS controller firmware DUP update while running a native Linux driver may cause the system/data volumes on the SAS controller to become inaccessible or Read-Only.

The recommended steps to update the SAS controller using the firmware DUP package on a Linux system to this new software level are as follows:
1.Upgrade the driver
2.Reboot the system
3.Upgrade the firmware
4.Reboot the system

The problem does not occur if the SAS controller FW is updated from a bootable device (non Linux environment).
SAS 6/iR Integrated
Performing the Firmware Upgrade

NOTE: This initial section of the Installation Instructions applies only to configurations with (greater than) 2TB SEDs.

1. Update the firmware version to this version using preferred method below (Zip Pack, Windows DUP, Linux DUP).
2. Reboot for the new FW take effect
3. Un-assign any (greater than) 2TB SED Dedicated or Global Hot Spares in the configuration. Not all configurations have hot spares.
4. Use CTRL-R or OMSS to issue Instant Secure Erase to all un-configured (greater than) 2TB SED drives (all data in these drives will be lost)
5. Re-assign (greater than) 2TB SED Hot Spares.

Zip pack:

Download
1. Click the Download Now link to download the file.
2. When the File Download window appears, click Save to save the file to your
hard drive.

Extract Files
1. Browse to the location where you downloaded the file and double-click the
new file to unzip the download package
2. Click Continue.
3. Specify the location to unzip the files.
4. Click onthe OK button to extract files.
After the files are extracted the message all files were successfully
unzipped will appear.
5. Click the OK button to exit from the installer.

Installation
1. Copy extracted files to bootable media.
2. Reboot system to bootable media.
3. Execute update.bat to perform flash.
5. After flash is complete, remove bootable media.
4. Reboot system for changes to take effect.


Windows Update Package:

Download
1. Click the "Download Now" link to download the file.
2. When the File Download window appears, click Save to save the file to
your hard drive.

Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window
before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.


Linux Update Package:

Download
1. Click the Download Now linkto download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.

Installation
1. Read over the release information presented by executing the
./FRMW_LX_RXXXXXX.BIN --version command from the shell.
2. Download and install any prerequisites identified in the above step before
proceeding.
3. Run the update by executing ./FRMW_LX_RXXXXXX.BIN from the shell.
4. Follow the remaining prompts to perform the update.

GnuPG Signature of Dell Update Package Instructions for FRMW_LX_RXXXXXX.BIN:

Download
1. Click the Download Now link to download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.

Installation
1. Import the Dell public key. (You only need to do this once on your system.)
2. Verify the Dell Update Package by using its signature file, FRMW_LX_RXXXXXX.BIN.

驅動程式說明與教學課程