Adaptec PERC2/Si, v.2.8.1.6098, A14

已自動安裝 此檔案會在最近更新時自動安裝。如果您遇到任何問題,可以手動下載並重新安裝。
此頁面的內容可能經過電腦自動翻譯。若要提供意見回饋,請填寫頁面底部的表單。
This software contains v2.8.1.6098 Firmware for the PowerEdge PE2400 PERC 2/Si controller.
建議

為您的系統尋找最適合的下載項目

請輸入產品的詳細資料以檢視系統的最新驅動程式資訊

搜尋支援

輸入您的 Dell 產品服務編號或型號

想要尋找您的產品嗎?請輸入產品識別碼。 告訴我怎麼做

此驅動程式不相容

此驅動程式不適用於選取的產品。請選擇其他產品,以重新輸入適用於此驅動程式的產品詳細資料,或前往產品支援頁面,檢視其他產品的所有驅動程式。

尋找更多更新。使用 SupportAssist 為您的裝置尋找所有最新的驅動程式更新。

修復及強化

Fixes and Enhancements
======================
2.8.1 Build 6098
----------------
- fixed an issue which occurs when reconfiguring an array with CLI while array was under stress; can result in kernel panic in Linux.
- fixed a bug where a 300GB hard drive could not be assigned as a hot spare for a 300GB R1 using full drive capacities.

2.8.1 Build 6097
----------------
-fixed a defect which occurs when reconfiguring an array to a size greater than 1.09 terabytes; can result in data loss.
–fixed bug where previous firmware did not re-calculate disk capacity when a drive is replaced.

2.8.0 Build 6095
----------------
-single bit change to turn off flag indicating 64-bit compatibility. Needed to fix OMSS Enclosure support issue with RHEL4.

2.8.0 Build 6092
----------------
-Background controller cache flush routine modified to flush smaller number of buffers during I/O without impacting RAID throughput. This change fixes driver timeout (manifesting as loss of drive access and filesystem errors like ext3_get_inode_loc errors) seen under certain Linux configurations.

2.8.0 Build 6089
----------------
-Default changed to 30 Second Timeout for controller BIOS option to pause or continue when RAID configuration is found altered or degraded. This behavior is same as pre v2.8 firmware behavior.

2.8.0 Build 6082 - Initial release of v2.8 firmware
---------------------------------------------------
-The ROMB firmware modified eliminating need for separate SCSI driver when channel-B is configured
as SCSI. Now only one driver is needed for both RAID/RAID and RAID/SCSI configurations (not applicable to PERC2/QC).
-Controller BIOS option added to pause or continue after 30 seconds timeout when RAID configuration is found altered or degraded.
-Additional ESM fix for pulled/missing drives.
-HIM_PCI_ERR correction to power management interrupt.
-Cache flush loop decreased to prevent extensive spin-lock hold during high I/O.
-AFU fix to block firmware installation based on proper level System BIOS.
-SCSI Passthru Event filtering.
-Disallow selection of drive to create raid when already reach maximum limit.
-Disable interrupts around doing queue accesses in CompleteFIB( ).
閱讀更多

繁體中文版

2.8.1.6098, A14

發佈日期

13 10月 2005

下載類型

韌體

類別

SCSI RAID

重要性

建議
Dell Technologies 建議您在下一個排定的更新週期套用此更新。此更新包含的變更可維持整體的系統健全狀況。此更新可確保系統軟體保持在最新狀態並與其他系統模組 (韌體、BIOS、驅動程式及軟體) 相容,並且可能包含其他新功能。
可用的格式

檔案格式: 適用於 MS Windows (32 位元) 的更新套件
檔案名稱: PE2400_RAID_FRMW_WIN_A14.EXE
檔案大小: 1.91 MB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
Microsoft Windows 32 位元格式的 Dell 更新套件 (DUP) 經過精心設計,可在 Microsoft Windows 64 位元作業系統上執行。Microsoft Windows 64 位元格式的 Dell 更新套件 (DUP) 只能在 Microsoft Windows 64 位元作業系統上執行。選擇裝置驅動程式更新時,請務必選擇適用您作業系統的更新。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
052768D2440F8F73573CE5A36CDEB6B1
SHA1:
不適用
SHA-256:
不適用

檔案格式: 自動解壓縮 zip 檔之中有一個以上的自動解壓縮磁碟影像
檔案名稱: PE2400-281_6098-A14.exe
檔案大小: 1.01 MB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
此檔案內含已壓縮的檔案集。將檔案下載到硬碟上的資料夾,然後按兩下以解壓縮該檔案集。請依照指示完成安裝。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
不適用
SHA1:
不適用
SHA-256:
不適用

檔案格式: 適用於 Red Hat Linux 的更新套件
檔案名稱: PE2400_RAID_FRMW_LX_A14.BIN
檔案大小: 1.84 MB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
適用於 Linux 的 Dell 更新套件可做為獨立的應用程式,確保符合特定的驗證條件,然後套用更新。
注意:適用於 Linux 的更新套件為開放原始碼套件。請參閱適用於 Linux 的 Dell 更新套件的「讀我」檔案,瞭解詳情。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
9CF60979DE37AD3C8645F574AE48D783
SHA1:
不適用
SHA-256:
不適用

當您開始下載,即表示您接受 Dell 軟體授權協定 (英文版) 的條款。

其他詳細資料

顯示全部 | 隱藏全部
Instructions for PE2400-281_6098-A14.exe

Download

1. Click the Download Now link to download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.

Diskette Creation
1. Browse to the location where you downloaded the file and double-click the new file to create the diskette set.
2. Insert a blank diskette then click Continue.
3. When prompted, repeat step 2 until you reach the end of the diskette set. Label each diskette with a disk number starting from 1.
4. After all the files have been copied to the last diskette, click Finish.


Firmware Installation
=========================
The firmware update utility on this diskette is DOS-based and named AFU.EXE. It offers both interactive and command line modes.


Performing the PERC 2/Si Firmware Upgrade in Interactive Mode
-------------------------------------------------------------
The AFU interactive mode is entered by issuing the AFU command with no command line switches. This mode simplifies the firmware update process for PERC 2/Si when one or more PERC 2/3 controllers are present.

To update the firmware using the AFU interactive mode, follow these steps:

1. Shut down your system.

2. Reboot the system with the diskette labeled:
DELL PERC 2/Si Firmware
Disk 1 of 2

***NOTE: If the system has not been set up to boot from the diskette, please read system documentation for instructions on how to set this up.

3. At the DOS prompt, enter the following command and press ENTER:

A:\> AFU

This starts the AFU in interactive mode. The AFU will detect the integrated PERC 2/Si and any installed PERC 2 controllers and present them for selection in a list.

4. If only PERC 2/Si is detected then AFU will select it. Otherwise, using the arrow keys, highlight PERC 2/Si and select it by pressing the space bar and press ENTER.

5. A "Select an Operation" menu will be presented. Select the following option and press ENTER:

Update flash image

6. The AFU will issue the following message:

Update from the flash image file in directory:
A:
Change the directory if necessary, then use the TAB key to select the OK box, and press ENTER.

7. AFU will issue following message:

Reading flash image file (Build xxxx)...

8. AFU will issue following message after reading flash image from first diskette:

Please insert disk labeled "PERC 2/Si Firmware disk 2"

9. Insert the second diskette and press ENTER.

10. AFU will complete reading the flash image and issue following message:

AFU is about to update firmware on controller(s) Dell PERC 2/Si
*** PLEASE DO NOT REBOOT THE SYSTEM DURING THE UPDATE ***
This might take a few minutes. Select OK to continue.


11. Select the OK box, then press ENTER. AFU will proceed to update the firmware and issue following message:

Writing PERC 2/Si integrated flash image to controller 0 ...

This message will be followed by additional progress messages. When the flash update has completed, you will see this message:

Controller #0 Dell PERC 2/Si
Flash image was updated and verified successfully

***NOTE: If you selected multiple controllers, AFU will prompt you to insert the diskette after the successful update of first controller. Please insert firmware diskette 1 for second controller.

12. Press any key, then press the ESC key to exit AFU. Remove any diskettes from the drive and reboot the system.

***NOTE: System must be rebooted after performing firmware update on PERC 2/Si before attempting any access to drives attached to the controller.

Performing the Controller Firmware Upgrade in Command Line Mode
---------------------------------------------------------------
AFU in command line mode returns its exit status (zero for success or non-zero for an error) in the DOS environment variable ERRORLEVEL.

The following instructions explain how to upgrade the controller fir