Maxtor Cobra 10K U320 36GB 68 Pin, Cobra 10K U320 36GB 80 Pin, Cobra 10K U320 73GB 68 Pin, Cobra 10K U320 73GB 80 Pin, Cobra 10K U320 146GB 68 Pin, Cobra 10K U320 146GB 80 Pin, v.1.0, A00

已自動安裝 此檔案會在最近更新時自動安裝。如果您遇到任何問題,可以手動下載並重新安裝。
此頁面的內容可能經過電腦自動翻譯。若要提供意見回饋,請填寫頁面底部的表單。
This utility disables the startup gamma calibration routine from Maxtor Atlas 10K drives
建議

為您的系統尋找最適合的下載項目

請輸入產品的詳細資料以檢視系統的最新驅動程式資訊

搜尋支援

輸入您的 Dell 產品服務編號或型號

想要尋找您的產品嗎?請輸入產品識別碼。 告訴我怎麼做

此驅動程式不相容

此驅動程式不適用於選取的產品。請選擇其他產品,以重新輸入適用於此驅動程式的產品詳細資料,或前往產品支援頁面,檢視其他產品的所有驅動程式。

尋找更多更新。使用 SupportAssist 為您的裝置尋找所有最新的驅動程式更新。

修復及強化

Initial Release
History: on power up, Maxtor Atlas 10K drives generate an audible noise while executing Gamma Calibration. This noise is part of the normal start up procedure; there are no problems with the drive. This noise will not occur during an active or idle drive state after the system is fully powered on and entered a ready state. This utility disables the startup gamma calibration routine.
閱讀更多

繁體中文版

1.0, A00

發佈日期

02 10月 2003

下載類型

公用程式

類別

SCSI 硬碟

重要性

選用
Dell Technologies 建議您檢閱此更新,以判斷其是否適用於您的系統。此更新包含的變更僅會影響特定組態,或其提供的新功能不一定適用於您的環境。
可用的格式

檔案格式: 自動解壓縮 zip 檔之中有一個以上的自動解壓縮磁碟影像
檔案名稱: BR66869.exe
檔案大小: 853.34 KB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
此檔案內含已壓縮的檔案集。將檔案下載到硬碟上的資料夾,然後按兩下以解壓縮該檔案集。請依照指示完成安裝。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
不適用
SHA1:
不適用
SHA-256:
不適用

當您開始下載,即表示您接受 Dell 軟體授權協定 (英文版) 的條款。

其他詳細資料

顯示全部 | 隱藏全部
Cobra 10K U320 146GB 68 Pin
Cobra 10K U320 146GB 80 Pin
Cobra 10K U320 36GB 68 Pin
Cobra 10K U320 36GB 80 Pin
Cobra 10K U320 73GB 68 Pin
Cobra 10K U320 73GB 80 Pin
Custom Instructions for BR66869.exe:

Utility must be placed on a non-write protected diskette.

NOTE: In order to create this diskette, the file must be downloaded to and executed on a system running Microsoft Windows.

Download
1. Click the "Download Now" link to download the file.
2. If the Export Compliance Disclaimer window appears, click the "I agree" link to accept the agreement.
3. When the File Download window appears, click "Save" to save the file to your hard drive.

Diskette Creation
1. Browse to the location where you downloaded the file and double-click the new file to create the diskette set.
2. Insert a blank diskette then click Continue.
3. After all the files have been copied to the last, click Finish.

Installation:
NOTE: BACKUP ALL DATA BEFORE RUNNING THIS PROGRAM. Do not remove power from the devices or disturb the devices in any way while the download is in progress. Dell, Inc is not Responsible for any data loss resulting from the use of this program

NOTE: Before proceeding with the update, refer to README.TXT file, section 4.0 "Using The Update Utility" for important information regarding the update process.

For drives connected to Channel 0 of an LSI RAID controller (PERC 3/SC, PERC 3/DC, PERC 3/DCL, PERC 3/QC, PERC 4/Di, PERC 4/SC, PERC 4/DC):
1. Insert the firmware update diskette into the floppy drive and reboot the system.
2. The utility will automatically determine the correct device to update when booted
3. Once the update is complete Remove the diskette and reboot the system.

For drives connected to Channel 1 of an LSI RAID controller (PERC 3/SC, PERC 3/DC, PERC 3/DCL, PERC 3/QC, PERC 4/Di, PERC 4/SC, PERC 4/DC):
1. Modify the CONFIG.SYS file on the diskette by removing the 'REM' statement in the line “Device=ASPIDRV\MEGASPI.SYS /a1” and adding the REM statement to the line “Device=ASPIDRV\MEGASPI.SYS /a0”.
2. Insert the firmware update diskette into the floppy drive and reboot the system.
3. The utility will automatically determine the correct device to update when booted
4. Once the update is complete Remove the diskette and reboot the system.


For drives connected an Adaptec RAID controller (PERC 3/Si, PERC 3/DI):
1. Modify the CONFIG.SYS file on the diskette by removing the 'REM' statement in the line "Device=ASPIDRV\ELITEAPI.SYS /M" and adding the ‘REM’ statement to the lines “Device=ASPIDRV\MEGASPI.SYS /a0” and “Device=ASPIDRV\MEGASPI.SYS /a1”.
2. Insert the firmware update diskette into the floppy drive and reboot the system.
3. The utility will automatically determine the correct device to update when booted
4. Once the update is complete Remove the diskette and reboot the system.

驅動程式說明與教學課程