Firmware SES per Dell PowerVault 220S/221S, v.E.17, A06

INSTALLATO AUTOMATICAMENTE Questo file è stato installato automaticamente come parte di un aggiornamento recente. In caso di problemi, è possibile scaricarlo e reinstallarlo manualmente.
È possibile che il contenuto di questa pagina sia stato tradotto automaticamente. Per fornire un feedback, compila il modulo che si trova in fondo alla pagina.
The PV22xS_E17.bin file is the downloadable version of the enclosure firmware that provides management functions for the PowerVault 220S/221S. These functions include SCSI Enclosure Services (SES) and SCSI Accessed Fault-Tolerant Enclosures (SAF-TE) reporting to the host initiator, control of all enclosure LED indicators, and monitoring of all the enclosure's environmental elements.
Consigliato

Trova il download migliore disponibile per il sistema

Inserisci i dettagli del prodotto per visualizzare le ultime informazioni sui driver per il sistema

Cerca supporto

Inserisci il modello o il codice di matricola Dell

Desideri cercare il tuo prodotto? Inserisci l'ID del prodotto. Mostrami come procedere

Questo driver non è compatibile

Questo driver non è applicabile per il prodotto selezionato. Scegli un altro prodotto per inserire nuovamente i dettagli per questo driver o visita la pagina supporto prodotti per visualizzare tutti i driver disponibili per un prodotto diverso.

Trova ulteriori aggiornamenti. Usa SupportAssist per trovare tutti gli ultimi aggiornamenti dei driver per il tuo dispositivo.

Correzioni e miglioramenti

Firmware E.17 is strictly a maintenance release for PV220S/PV221S. Dell recommends that all PV220S/PV221S be at minimal level of E.16 or greater. Systems having E.16 is not required to upgrade to E.17, which provides the following updates: Removed reading of fans and power supply FRU part numbers to fix manufacturing test issues. FRU (Field Replaceable Units) are also referred to as service part numbers. No impact to customers since service calls always cross reference to the latest available service part number. Add retry operations to read FRUs if it failed to read previously during enclosure initialization.
Più dettagli

Versione

E.17, A06

Data di rilascio

26 ago 2005

Tipo di download

Firmware

Categoria

DAS

Importanza

Consigliato
Dell Technologies consiglia di eseguire questo aggiornamento nel prossimo ciclo di aggiornamenti pianificato. L'aggiornamento contiene modifiche per preservare l’integrità generale del sistema. Inoltre, garantisce che il software di sistema resti aggiornato e compatibile con altri moduli di sistema (firmware, BIOS, driver e software) e includa nuove funzioni.
Formati disponibili Visualizza le informazioni importanti

Formato file: Pacchetto di aggiornamento per Microsoft Windows a 32 bit
Nome file: FRMW-R74083.exe
Dimensioni file: 2.24 MB
File di grandi dimensioni. A seconda della velocità di connessione, l'operazione di download potrebbe richiedere tempo.
Descrizione del formato:
I pacchetti di aggiornamenti Dell (DUP) in formato Microsoft Windows a 32 bit sono stati progettati per essere eseguiti su sistemi operativi Microsoft Windows a 64 bit. I pacchetti di aggiornamenti Dell (DUP) in formato Microsoft Windows a 64 bit verranno eseguiti solo su sistemi operativi Microsoft Windows a 64 bit. Quando si seleziona un aggiornamento dei driver di un dispositivo, assicurarsi di selezionare quello appropriato per il sistema operativo in uso.
Per assicurare l'integrità del download, verificare il valore del checksum.
MD5:
B898B9D875B654604EEF9C8BE09DB053
SHA1:
Non disponibile
SHA-256:
Non disponibile

Formato file: Estrae file direttamente sul disco locale
Nome file: FUPG_E17.exe
Dimensioni file: 48.54 KB
File di grandi dimensioni. A seconda della velocità di connessione, l'operazione di download potrebbe richiedere tempo.
Descrizione del formato:
Questo formato di file è costituito da un archivio di file che possono essere decompressi in una directory sul disco rigido. L'installazione può essere quindi eseguita da tale directory.
Per assicurare l'integrità del download, verificare il valore del checksum.
MD5:
Non disponibile
SHA1:
Non disponibile
SHA-256:
Non disponibile

Formato file: Pacchetto di aggiornamento per Red Hat Linux
Nome file: FRMW-R74083.bin
Dimensioni file: 2.01 MB
File di grandi dimensioni. A seconda della velocità di connessione, l'operazione di download potrebbe richiedere tempo.
Descrizione del formato:
I pacchetti Dell Update Packages per Linux possono essere utilizzati come applicazioni standalone che assicurano che vengano soddisfatti criteri di convalida specifici prima di eseguire un aggiornamento.
Nota: i pacchetti di aggiornamento per Linux sono open source. Informazioni dettagliate sono contenute nel file leggimi dei pacchetti Dell Update Packages per Linux.
Per assicurare l'integrità del download, verificare il valore del checksum.
MD5:
B783C566741E5AD223AE1F4008B217AD
SHA1:
Non disponibile
SHA-256:
Non disponibile

Con il download l'utente accetta i termini del Contratto di licenza del software Dell. (in Inglese)

Ulteriori dettagli

Mostra tutto | Nascondi tutto
Known Limitations:
  1. In Joined bus/Clustering mode, firmware is downloaded to both EMMs automatically (assuming that the second EMM is installed) by failing over and then failing back. In Split bus mode, however, updating firmware on one EMM does not automatically update the other EMM. Therefore, in order to update both EMMs, the user must download directly through the cable to each EMM.

  2. When using Array Manager 3.1.1 (or less) in Clustering mode, EMM firmware can only be upgraded on the primary EMM (the left one when viewing the enclosure from the back). Therefore, in order to update both EMMs, the user must download firmware to each EMM individually.

  3. If the PV22XS is configured with one EMM and one termination module in Joined bus mode, an error message will pop up when upgrading the firmware through Array Manager 3.1.1 (or less). This is an invalid error message in this scenario. If the fans have gone back to normal speed, then the firmware download was successful. To verify this, stop and restart the Disk Management Service. Then you can view the firmware version under the enclosure properties.

  4. Firmware updates to enclosures attached to PERC 2/DC, PERC3/SC/QC/DC/DCL, or any PERC4 array controllers require that Array Manager be at release 3.4 or greater; while PERC 2/QC or PERC 3/Di controllers require that Array Manager be at least 3.5 or greater.

Custom Instructions for FUPG_E17.exe:

Updating Firmware Using Array Manager
(Windows & NetWare)


Dell OpenManage Array Manager software provides a comprehensive storage management solution that enables you to configure and manage local and remote storage attached to a system. Array Manager includes an integrated firmware update utility that can be used with the following operating ystems:

  • Windows 2000 Server and Advanced Server

  • Windows Server 2003

  • Novell NetWare (all Dell-supported versions)


To update the firmware on your PowerVault 22xS storage system using Array Manager:

NOTE: In the following steps, xx refers to the firmware release number.

  1. Stop all I/O activity to the storage system.

  2. Create a directory on your local file system.

  3. Download the FUPG_E.xx.EXE file to a directory on your hard drive. The file downloaded is a self-extracting executable. step 2.

  4. Double-click the FUPG_Exx.exe file to extract the firmware update files to your system's hard drive.

  5. On the host system, click the Start button and select Programs > Dell OpenManage Applications
    > Array Manager > Array Manager Console.

  6. Select Arrays > PERC Subsystem.

  7. Select the controller that is linked to the enclosure you are upgrading.

  8. Right-click the enclosure object and select Download Firmware.

  9. Navigate to the .bin file that was extracted in step 4.

  10. Double-click the .bin file and follow the directions on your screen. When the update is complete, a message appears indicating that the update was successful.

    Note: The firmware update may take up to 5 minutes to complete depending on the server speed. Please allow the appropriate time for the firmware update to complete.

  11. Restart I/O activity to the storage system.



Custom Instructions for FRMW-R74083.exe:

Windows Dell Update Packages Procedure


Dell Update Packages (DUPs) are software utilities provided by Dell to update specific software components on your Dell system. DUPs provide an easy-to-use graphical user interface (GUI) that enables you to apply a software update to either a single system or, remotely, to multiple systems using your organization’s software distribution tools. DUPs run separately from Array Manager, so you can use a DUP if Array Manager is not available on your host system. Dell provides DUPs for the following operating systems:


  • Windows 2000 Server and Advanced Server

  • Windows Server 2003

  • Red Hat Enterprise Linux (Version 2.1)

  • Red Hat Enterprise Linux (Version 3) for Intel x86


Windows DUP Update Procedure

The following procedure updates the firmware on a PowerVault 22xS storage system that is attached to a host system that is running the 32-bit version of Windows 2000 Server, Advanced Server, or Windows Server 2003, without Array Manager.
  1. Stop all I/O activity to the storage system.

  2. Create a directory on your local file system.

  3. Download the executable Windows DUP package file (PV220s-221s-FRMW-Rxxxxx.exe, where Rxxxxx indicates the release) from the Dell Support website at support.dell.com and save the file to the directory you created in step 2.

  4. Double-click the downloaded file to uncompress the file and start the update.

  5. When prompted, click Install to update the firmware. When the update is complete, a message appears indicating that the update was successful.

  6. Restart I/O activity to the storage system.


Custom Instructions for FRMW-R74083.bin:

Linux Dell Update Packages


Tutorial e guida ai driver