Dell OpenManage Connection v2.1 for IBM Tivoli Netcool/OMNIbus 7.3.1 and 7.4
AUTOMATISK INSTALLERTDenne filen ble automatisk installert som en del av en nylig oppdatering. Hvis du opplever problemer, kan du laste ned og installere på nytt manuelt.
Innholdet på denne siden kan ha blitt oversatt automatisk. Fyll ut skjemaet nederst på siden for å gi tilbakemelding.
Denne filen ble automatisk installert som en del av en nylig oppdatering. Hvis du opplever problemer, kan du laste ned og installere på nytt manuelt.
In environments managed by IBM Tivoli Netcool/OMNIbus, Dell OpenManage Connection version 2.1 for IBM Tivoli Netcool/OMNIbus 7.3.1 and 7.4 provides event monitoring capabilities for Dell PowerEdge Servers (9G-12G), Dell PowerVault Storage Servers (9G-12G), Integrated Dell Remote Access Controller 7 (iDRAC7), Integrated Dell Remote Access Controller 6 (iDRAC6), Dell Remote Access Controller 5 (DRAC5), Dell PowerEdge M1000e Chassis (CMC), Dell PowerEdge VRTX (VRTX CMC), Dell PowerEdge 1955 Chassis (DRAC/MC), Dell EqualLogic Storage Arrays PS Series, and Dell PowerVault MD Storage Arrays. This connection software also supports one-to-one console launch of above Dell devices and Dell Tools launch (OME) from Dell device alerts and polled events in OMNIbus console.
Anbefalt
Finn den beste nedlastingen for systemet
Angi produktdetaljer for å vise den nyeste driverinformasjonen for systemet
Støtte for søk
Skriv inn Dell-service-ID-en eller -modellen
Ønsker du å finne produktet? Skriv inn en produktidentifikator.Vis meg hvordan
Finner ingen resultater. Vi finner ikke noe for søket ditt. Endre valget ditt, og prøv på nytt.
Denne driveren er ikke kompatibel
Denne driveren er ikke gjeldende for det valgte produktet. Velg et annet produkt for å angi produktopplysningene dine for denne driveren på nytt, eller gå til siden for produktstøtte for å vise alle drivere for et annet produkt.
Logg på Windows som administrator for å bruke automatisk skanning. Hvis du allerede er logget på som administrator og ser denne meldingen, må du starte maskinen på nytt.Systemet ditt blir administrert av IT-administratoren, og funksjonene kan være begrenset.
Finn flere oppdateringer. Bruk SupportAssist for å finne alle de nyeste driveroppdateringene for enheten din.
Feilrettinger og forbedringer
Enhancement 1. Monitor alerts from Dell MD Storage Arrays. 2. Out-of-Band alerts correlation from Dell 12G Servers. 3. Monitor new OpenManage Server Administrator (OMSA) and OpenManage Storage 4. Management (OMSS) alerts (OM release 7.1 to 7.3) from Dell PowerEdge and PowerVault Servers. 5. Support for Dell Modular Disk Storage Manager console (MDSM) launch. 6. Support for Dell Connection License Manager console (DCLM) launch. 7. Simplified installation of Dell OpenManage connection.
Fixes The following Dell Server alerts are displayed on the OMNIbus console with severity as "Indeterminate" and group as "DellServerAdministratorStorageMgmt" - An EMM has been removed - An EMM has been inserted
In the OMNIbus Console, the following Dell 12G out-of-band server Traps are displayed with severity as "Indeterminate" and group as "DellOOBServer" (group should ideally display respective object names, instead of "DellOOBServer").
- Battery Object Traps - BAT1000 : Battery on is missing. - BAT1008 : Write policy on was changed to Write Through. - BAT1021 : The charge level for the battery on is below the normal threshold. - BAT1024 : Errors detected with battery on . - BAT1025 : is unable to recover cached data from the Battery Backup Unit (BBU). - BAT1033 : The battery on was removed.
- Controller Object Traps - CTL48 : A foreign configuration was detected on . - CTL72 : The foreign configuration overflow has occurred on . - CTL73 : Foreign configuration is imported only partially. Some configurations failed to import on .
- PhysicalDisk Object Traps - PDR73 : Copyback failed from to . - PDR85 : Security subsystem errors detected for . - PDR86 : Bad block table on is full. - PDR95 : Microcode update on has failed.
- PowerSupply Object Traps - PSU1 : Power supply in was disrupted. - PSU2 : The power supply in is switched OFF. - PSU11 : Power supply in has failed.
Dell Technologies anbefaler at du går gjennom denne oppdateringen for å finne ut om den gjelder for systemet ditt. Oppdateringen inneholder endringer som bare påvirker bestemte konfigurasjoner, eller som gir nye funksjoner som kanskje gjelder miljøet ditt.
Download 1. From dell.com/support, download the Dell_OpenManage_Connection_for_OMNIbus_v2_1.zip file. 2. When the File Download window appears, click Save to save the file to your hard drive.
Extract Files 1. Browse to the location where you downloaded the file and double-click the new file to unzip the download package. 2. Click Continue. 3. Specify the location to unzip the files. 4. Click OK to extract files. After the files are extracted the message all files were successfully unzipped will appear. 5. Click OK to exit from the installer.
Install 1. Follow the installation instructions in the Installation Guide to install the Dell OpenManage Connection v2.1.