Dell PERC 6/E Adapter FW, v.6.2.0-0013, A11

Omstart kreves AUTOMATISK INSTALLERT Denne filen ble automatisk installert som en del av en nylig oppdatering. Hvis du opplever problemer, kan du laste ned og installere på nytt manuelt.
Innholdet på denne siden kan ha blitt oversatt automatisk. Fyll ut skjemaet nederst på siden for å gi tilbakemelding.
Dell PERC6 firmware maintenance release version 6.2.0-0013 Performance enhancements include significant improvements in random-write performance, multi-threaded write performance, and reduction in maximum and average I/O response times.
Anbefalt

Finn den beste nedlastingen for systemet

Angi produktdetaljer for å vise den nyeste driverinformasjonen for systemet

Støtte for søk

Skriv inn Dell-service-ID-en eller -modellen

Ønsker du å finne produktet? Skriv inn en produktidentifikator. Vis meg hvordan

Denne driveren er ikke kompatibel

Denne driveren er ikke gjeldende for det valgte produktet. Velg et annet produkt for å angi produktopplysningene dine for denne driveren på nytt, eller gå til siden for produktstøtte for å vise alle drivere for et annet produkt.

Finn flere oppdateringer. Bruk SupportAssist for å finne alle de nyeste driveroppdateringene for enheten din.

Feilrettinger og forbedringer

1. Enhanced disk IO performance in multiple SAS and SATA configurations.

2. Improved random IO performance.

3. Improved response and completion times for random IO.

4. Increased SATA disk command queue depth.

5. Improved disk medium error correction in certain scenarios.

6. Improved handling of faulty backplanes and enclosures.

7. Resolved an issue where a predicted failure was still being reported after that drive was replaced.

8. Corrected an issue where SATA disks in an MD1000 may become foreign after the server and enclosure are power-cycled.

9. Resolved an issue where the controller could not handle a large number of rebuilds under heavy IO stress.

10. Fixed an issue where Windows Server 2008 installation in uEFI mode fails when installing to a virtual disk larger than 2 terabytes.

11. Fixed an issue where some Intel platforms with a PERC 6 installed occasionally fail with Windows Hardware Malfunction blue screen error during OS reboots.

12. Made several cosmetic and usability enhancements to improved customer experience.
Les mer

Versjon

6.2.0-0013, A11

Utgivelsesdato

06 des. 2011

Nedlastingstype

Fastvare

Kategori

SAS RAID

Viktighet

Anbefalt
Dell Technologies anbefaler at du installerer denne oppdateringen ved neste planlagte oppdatering. Oppdateringen inneholder endringer for å opprettholde den generelle systemtilstanden. Det sikrer at systemprogramvaren forblir oppdatert og kompatibel med andre systemmoduler (fastvare, BIOS, drivere og programvare) og kan inkludere andre nye funksjoner.
Tilgjengelige formater Se viktig informasjon:

Filformat: Oppdateringspakke for MS Windows 32-biters
Filnavn: RAID_FRMW_WIN_R216021.EXE
Filstørrelse: 5.95 MB
Dette er en stor fil. Avhengig av tilkoblingshastigheten kan det ta litt tid å laste den ned.
Formatbeskrivelse:
Dells oppdateringspakker (DUP) i Microsoft Windows 32-bitersformat er utformet for å kjøre på Microsoft Windows 64-biters operativsystemer. Dells oppdateringspakker (DUP) i Microsoft Windows 64-bitersformat kan bare kjøre på Microsoft Windows 64-biters operativsystemer. Når du velger en enhetsdriveroppdatering, må du velge en som passer til operativsystemet.
Kontroller kontrollsumverdien for å sikre integriteten til nedlastingen.
MD5:
E16A1568DD52E51803223F4BE56842E8
SHA1:
Ikke tilgjengelig
SHA-256:
Ikke tilgjengelig

Filformat: En GnuPG-fil som inneholder en kryptografisk signatur
Filnavn: RAID_FRMW_LX_R216021.BIN.sign
Filstørrelse: 194 Bytes
Dette er en stor fil. Avhengig av tilkoblingshastigheten kan det ta litt tid å laste den ned.
Formatbeskrivelse:
GnuPG-signaturen for Red Hat Linux-oppdateringspakken kan brukes til å godkjenne Dells identitet i den tilhørende Red Hat Linux-oppdateringspakken.
Kontroller kontrollsumverdien for å sikre integriteten til nedlastingen.
MD5:
8EE0435224E1A65AF6B1E14AE928E862
SHA1:
Ikke tilgjengelig
SHA-256:
Ikke tilgjengelig

Filformat: Ekstern ZIP-pakke
Filnavn: DELL_PERC-6-E-ADAPTER_A11_R216021.exe
Filstørrelse: 1.89 MB
Dette er en stor fil. Avhengig av tilkoblingshastigheten kan det ta litt tid å laste den ned.
Formatbeskrivelse:
Denne filen inneholder et komprimert (zippet) sett med filer. Last ned filen til en mappe på harddisken, og åpne den (dobbeltklikk) for å pakke ut settet med filer. Følg instruksjonene for å fullføre installeringen.
Kontroller kontrollsumverdien for å sikre integriteten til nedlastingen.
MD5:
b25054483bb89825b86162775cdf74f8
SHA1:
acaf05e64633bb748bdb1f2c56fa7bc3e873b586
SHA-256:
Ikke tilgjengelig

Filformat: Eksterne versjonsmerknader
Filnavn: R216021.txt
Filstørrelse: 14.34 KB
Dette er en stor fil. Avhengig av tilkoblingshastigheten kan det ta litt tid å laste den ned.
Formatbeskrivelse:
Dette filformatet inneholder ren tekst som kan vises med en vanlig tekstredigeringsprogram.
Kontroller kontrollsumverdien for å sikre integriteten til nedlastingen.
MD5:
494c840c900e9c662670a6b1b098c70a
SHA1:
Ikke tilgjengelig
SHA-256:
Ikke tilgjengelig

Filformat: Oppdateringspakke for Red Hat Linux
Filnavn: RAID_FRMW_LX_R216021.BIN
Filstørrelse: 4.45 MB
Dette er en stor fil. Avhengig av tilkoblingshastigheten kan det ta litt tid å laste den ned.
Formatbeskrivelse:
Dells oppdateringspakker for Linux kan brukes som frittstående programmer som sikrer at bestemte valideringskriterier er oppfylt, og deretter bruker en oppdatering.
Merk: Oppdateringspakker for Linux har åpen kildekode. Du finner mer informasjon i Dells oppdateringspakker for Viktig-filen i Linux.
Kontroller kontrollsumverdien for å sikre integriteten til nedlastingen.
MD5:
629F2391965A62A12E02ECAF3D12E6F1
SHA1:
Ikke tilgjengelig
SHA-256:
Ikke tilgjengelig

Ved å laste ned godtar du vilkårene i lisensavtalen for Dell-programvare. (på engelsk)

Mer informasjon

Vis alle | Skjul alle
1. When viewing SATA physical disk properties from Ctrl-R or other management applications, the Vendor Identification will be translated as "ATA" followed by blanks.

2. If all physical disks making up a virtual disk are removed from the system or enclosure, the RAID controller will delete the virtual disk. If the disks are later re-inserted, they will be marked foreign and can be imported using a management application.

3. If a virtual disk is configured with write-back cache enabled and some or all of its physical disks are removed from the system or enclosure, the RAID controller will preserve the virtual disk's write cache. The controller will flush the preserved cache when the physical disks are replaced and the foreign configuration is imported. Any attempt to update controller firmware will be blocked when cache is preserved for a virtual disk.

4. Physical disks determined to contain a foreign configuration are not available for configuration as a new dedicated or global hot spare, or as a member of a new virtual disk. The foreign configuration must be imported or cleared from the physical disk before it may be used as a hot spare or member of a virtual disk. Physical disks with a foreign configuration will not appear on the Create New VD screen in Ctrl-R.

5. Prior to performing a virtual disk migration to another system, the source system must be powered off before removal of the physical disks to preserve the correct virtual disk state. This is not required for the target system and the physical disks may be inserted while the system is powered on or off.

6. The controller restricts the importing of virtual disks that are undergoing RAID Level Migration or Capacity Expansion. Do not interrupt virtual disks that are performing either of these operations because it will disable the ability to import the virtual disk and the data will be unavailable. Dell recommends that the user perform a data backup before starting these operations.

7. EMM changes or drive migrations are not supported during a Capacity Expansion or Raid Level Migration. This may cause the VDs to go offline. Dell recommends the user to perform a data backup before starting these operations.

8. This version of firmware will not ensure complete compatibility with an older version of management applications. OpenManage 5.5 or greater is recommended.

9. It is recommended that the customer upgrade the management application and device driver to the latest version available from Dell at the time of installation of this firmware.

10. Important Information for Update Packages for Microsoft Windows

a. Do not run other applications while executing Dell Update Packages.
b. Do not run storage controller update packages if the controller is in use
by other applications. The firmware upgrade may fail if any of the
RAID controllers in the system are performing I/O background tasks
(consistency checks, background initializations, rebuilds, or
reconstructions). Allow the background tasks to complete before
attempting to upgrade the firmware. Patrol Read tasks will not affect
firmware upgrades.

11. Important Information for Update Packages for Linux

a. Do not run other applications while executing Dell Update Packages.
b. If the following error occurs, "Error while loading shared libraries:
libstdc++.so.5: cannot open shared object file: No such file or
directory", you must install the compatibility libraries. These
libraries can be found on the installation media or online. To install
the compatibility libraries, use the following commands:
"rpm -ih compat-libstdc++-33-3.2.3.-*.i386.rpm" for RHEL 4 or 5
"rpm -ih compat-libstdc++-5.0.7-*.x86_64.rpm" for SLES 10
c. When Update Packages stop abruptly due to a power outage or abnormal
termination, perform the following steps:
- Remove the lock file.
- Type the following command: rm -f /var/lock/.spsetup
- Run the Update Package again to reapply the update.
d. Do not ru
PERC 6/E Adapter
PERC 6/i Adapter
PERC 6/i Integrated
Performing the Firmware Upgrade

NOTE: This initial section of the Installation Instructions applies only to configurations with (greater than) 2TB SEDs.

1. Update the firmware version to this version using preferred method below (Zip Pack, Windows DUP, Linux DUP).
2. Reboot for the new FW take effect
3. Un-assign any (greater than) 2TB SED Dedicated or Global Hot Spares in the configuration. Not all configurations have hot spares.
4. Use CTRL-R or OMSS to issue Instant Secure Erase to all un-configured (greater than) 2TB SED drives (all data in these drives will be lost)
5. Re-assign (greater than) 2TB SED Hot Spares.

Zip pack:

Download
1. Click the Download Now link to download the file.
2. When the File Download window appears, click Save to save the file to your
hard drive.

Extract Files
1. Browse to the location where you downloaded the file and double-click the
new file to unzip the download package
2. Click Continue.
3. Specify the location to unzip the files.
4. Click onthe OK button to extract files.
After the files are extracted the message all files were successfully
unzipped will appear.
5. Click the OK button to exit from the installer.

Installation
1. Copy extracted files to bootable media.
2. Reboot system to bootable media.
3. Execute update.bat to perform flash.
5. After flash is complete, remove bootable media.
4. Reboot system for changes to take effect.


Windows Update Package:

Download
1. Click the "Download Now" link to download the file.
2. When the File Download window appears, click Save to save the file to
your hard drive.

Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window
before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.


Linux Update Package:

Download
1. Click the Download Now linkto download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.

Installation
1. Read over the release information presented by executing the
./FRMW_LX_RXXXXXX.BIN --version command from the shell.
2. Download and install any prerequisites identified in the above step before
proceeding.
3. Run the update by executing ./FRMW_LX_RXXXXXX.BIN from the shell.
4. Follow the remaining prompts to perform the update.

GnuPG Signature of Dell Update Package Instructions for FRMW_LX_RXXXXXX.BIN:

Download
1. Click the Download Now link to download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.

Installation
1. Import the Dell public key. (You only need to do this once on your system.)
2. Verify the Dell Update Package by using its signature file, FRMW_LX_RXXXXXX.BIN.

Hjelp og veiledninger for drivere