Emerson 750W PSU (PN: F613N) Firmware Package

Omstart kreves AUTOMATISK INSTALLERT Denne filen ble automatisk installert som en del av en nylig oppdatering. Hvis du opplever problemer, kan du laste ned og installere på nytt manuelt.
Innholdet på denne siden kan ha blitt oversatt automatisk. Fyll ut skjemaet nederst på siden for å gi tilbakemelding.
This package provides the new firmware for power supplier and is supported on Emerson 750W PSU (PN: F613N) running on the Windows and Linux operating systems.
Anbefalt

Finn den beste nedlastingen for systemet

Angi produktdetaljer for å vise den nyeste driverinformasjonen for systemet

Støtte for søk

Skriv inn Dell-service-ID-en eller -modellen

Ønsker du å finne produktet? Skriv inn en produktidentifikator. Vis meg hvordan

Denne driveren er ikke kompatibel

Denne driveren er ikke gjeldende for det valgte produktet. Velg et annet produkt for å angi produktopplysningene dine for denne driveren på nytt, eller gå til siden for produktstøtte for å vise alle drivere for et annet produkt.

Finn flere oppdateringer. Bruk SupportAssist for å finne alle de nyeste driveroppdateringene for enheten din.

Feilrettinger og forbedringer

Fixes
- Eliminate communication error issue.

Enhancements
- Not Applicable
Les mer

Versjon

Z1.0A.07, A02

Utgivelsesdato

09 mar. 2012

Nedlastingstype

Fastvare

Kategori

Strøm

Viktighet

Valgfritt
Dell Technologies anbefaler at du går gjennom denne oppdateringen for å finne ut om den gjelder for systemet ditt. Oppdateringen inneholder endringer som bare påvirker bestemte konfigurasjoner, eller som gir nye funksjoner som kanskje gjelder miljøet ditt.
Tilgjengelige formater Se viktig informasjon:

Filformat: Oppdateringspakke for MS Windows 32-biters
Filnavn: Power_Firmware_XNWX0_WN32_Z1.0A.07_A02.EXE
Filstørrelse: 4.28 MB
Dette er en stor fil. Avhengig av tilkoblingshastigheten kan det ta litt tid å laste den ned.
Formatbeskrivelse:
Dells oppdateringspakker (DUP) i Microsoft Windows 32-bitersformat er utformet for å kjøre på Microsoft Windows 64-biters operativsystemer. Dells oppdateringspakker (DUP) i Microsoft Windows 64-bitersformat kan bare kjøre på Microsoft Windows 64-biters operativsystemer. Når du velger en enhetsdriveroppdatering, må du velge en som passer til operativsystemet.
Kontroller kontrollsumverdien for å sikre integriteten til nedlastingen.
MD5:
6aafb9eaceb6fd98c79c42d9f017da1b
SHA1:
1d1b6e211b6ed1b1bca1281e6ebe94dfb94e82c4
SHA-256:
431cead86889c2efa9de9049cb2f98dcd1a08d0d32bad4f25ef89c9bb503f9ea

Filformat: En GnuPG-fil som inneholder en kryptografisk signatur
Filnavn: Power_Firmware_XNWX0_LN32_Z1.0A.07_A02.BIN.sign
Filstørrelse: 194 Bytes
Dette er en stor fil. Avhengig av tilkoblingshastigheten kan det ta litt tid å laste den ned.
Formatbeskrivelse:
GnuPG-signaturen for Red Hat Linux-oppdateringspakken kan brukes til å godkjenne Dells identitet i den tilhørende Red Hat Linux-oppdateringspakken.
Kontroller kontrollsumverdien for å sikre integriteten til nedlastingen.
MD5:
285f0d870f7cba65ee6b6b82c6b76cb5
SHA1:
5c20835eee251a4596e768c3f2889ce2fde59bed
SHA-256:
d752822a971783b8f9d79de22f70a83e7192dd20f2d7e57d08e19fee05ec4eab

Filformat: Oppdateringspakke for Red Hat Linux
Filnavn: Power_Firmware_XNWX0_LN32_Z1.0A.07_A02.BIN
Filstørrelse: 2.16 MB
Dette er en stor fil. Avhengig av tilkoblingshastigheten kan det ta litt tid å laste den ned.
Formatbeskrivelse:
Dells oppdateringspakker for Linux kan brukes som frittstående programmer som sikrer at bestemte valideringskriterier er oppfylt, og deretter bruker en oppdatering.
Merk: Oppdateringspakker for Linux har åpen kildekode. Du finner mer informasjon i Dells oppdateringspakker for Viktig-filen i Linux.
Kontroller kontrollsumverdien for å sikre integriteten til nedlastingen.
MD5:
fc60b359a0c3b8535194adfdac2870e3
SHA1:
f22db352e2ac192d32a64684f4a0f6a43e277ccf
SHA-256:
65eb257df26556674e375ebb9b27b7bda97ddece4fa6ddf2b94bb3efc9ce8cbc

Ved å laste ned godtar du vilkårene i lisensavtalen for Dell-programvare. (på engelsk)

Mer informasjon

Vis alle | Skjul alle
IMPORTANT:
After a successful power supply firmware download, the managed system turns off for a duration ranging from three to twenty minutes to continue updating the firmware. It is imperative not to interrupt/restart manually during this time. Update time can vary but should be approximately 10 minutes. Margin should be added to assure the Dell Update Package (DUP) is not interrupted (some DUPs may take up to 20 minutes). Once the firmware update is complete, the managed system reboots automatically.
750W (F613N) PSU
PSU FIRMWARE UPDATE INSTRUCTIONS:

CAUTION: Performing an AC power cycle or cold boot during a power supply firmware update, forces the power supply unit (PSU) into an irrecoverable state and the managed system does not boot.

IMPORTANT:
After a successful power supply firmware download, the managed system turns off for a duration ranging from three to twenty minutes to continue updating the firmware. It is imperative not to interrupt/restart manually during this time. Update time can vary but should be approximately 10 minutes. Margin should be added to assure the Dell Update Package (DUP) is not interrupted (some DUPs may take up to 20 minutes). Once the firmware update is complete, the managed system reboots automatically.


Instructions for ".BIN" file:

Download
1. Click the Download Now link to download the file.
2. When the "File Download" window appears, click Save to save the file to your hard drive.

Installation
1. Read the release information presented by executing the".BIN" file with "--version" command from the shell.
2. Download and install any prerequisites identified in the above step before proceeding.
3. Run the update by executing ".BIN" file from the shell.
4. Follow the remaining prompts to perform the update.
5. Upon successful completion the DUP will prompt to reboot system.
6. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
7. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
8. Once the flashing process is complete the system should power back up and boot to OS.

Instructions for ".EXE" file:

Download
1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to your hard drive.

Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.
6. Upon successful completion the DUP will prompt to reboot system.
7. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
8. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
9. Once the flashing process is complete the system should power back up and boot to OS.


GnuPG Signature of Dell Update Package Instructions for ".sign" file:

Download
1. Click the "Download Now" link to download the file.
2. When the "File Download" window appears, click "Save" to save the file to your hard drive.

Installation
1. Import the Dell public key. (You only need to import once on your system.)
2. Verify the Dell Update Package by using its signature file.
3. Upon successful completion the DUP will prompt to reboot system.
4. Restart your system.
After the system restarts, DUP will enter USC to complete the flashing of the PSU firmware.
5. The actual flash begins after DUP exits USC. Please do not power off or power cycle the system as this can result in a non-functional power supply.
6. Once the flashing process is complete the system should power back up and boot to OS.

Hjelp og veiledninger for drivere