Dell CERC 6/i Integrated FW, v.6.2.0-0013, A11

Reinicio requerido INSTALADO AUTOMÁTICAMENTE Este archivo se instaló automáticamente como parte de una actualización reciente. Si experimenta algún problema, puede descargarlo y reinstalarlo manualmente.
Es posible que el contenido de esta página se traduzca automáticamente. Para proporcionar comentarios, complete el formulario en la parte inferior de la página.
Dell PERC6/CERC6 firmware maintenance release version 6.2.0-0013 Performance enhancements include significant improvements in random-write performance, multi-threaded write performance, and reduction in maximum and average I/O response times.
Recomendado

Encuentre la mejor descarga para su sistema

Ingrese los detalles del producto para ver la información más reciente del controlador para el sistema

Buscar soporte

Ingrese su modelo o etiqueta de servicio de Dell

¿Desea buscar su producto? Ingrese un identificador de producto. Mostrarme cómo

Este controlador no es compatible

Este controlador no se corresponde con el producto seleccionado. Elija otro producto para volver a ingresar los detalles del producto para este controlador o visite la página Soporte de productos para ver todos los controladores de un producto diferente.

Encuentre más actualizaciones. Utilice SupportAssist para encontrar todas las actualizaciones de controladores más recientes para su dispositivo.

Correcciones y mejoras

1. Enhanced disk IO performance in multiple SAS and SATA configurations.

2. Improved random IO performance.

3. Improved response and completion times for random IO.

4. Increased SATA disk command queue depth.

5. Improved disk medium error correction in certain scenarios.

6. Improved handling of faulty backplanes and enclosures.

7. Resolved an issue where a predicted failure was still being reported after that drive was replaced.

8. Corrected an issue where SATA disks in an MD1000 may become foreign after the server and enclosure are power-cycled.

9. Resolved an issue where the controller could not handle a large number of rebuilds under heavy IO stress.

10. Fixed an issue where Windows Server 2008 installation in uEFI mode fails when installing to a virtual disk larger than 2 terabytes.

11. Fixed an issue where some Intel platforms with a PERC 6 installed occasionally fail with Windows Hardware Malfunction blue screen error during OS reboots.

12. Made several cosmetic and usability enhancements to improved customer experience.
Más información

Versión

6.2.0-0013, A11

Fecha de publicación

06 dic 2011

Tipo de descarga

Firmware

Categoría

RAID SAS

Importancia

Recomendado
Dell Technologies recomienda aplicar esta actualización durante su próximo ciclo de actualizaciones programadas. La actualización contiene cambios para mantener el estado general del sistema. Garantiza que el software del sistema permanezca actualizado y compatible con otros módulos del sistema (firmware, BIOS, controladores y software) y puede incluir otras funciones nuevas.
Formatos disponibles Ver información importante

Formato de archivo: Paquete de actualizaciones para MS Windows de 32 bits
File Name: RAID_FRMW_WIN_R216022.EXE
Tamaño del archivo: 5.95 MB
Este es un archivo grande. La descarga puede tardar, dependiendo de la velocidad de conexión.
Descripción del formato:
Los paquetes de actualizaciones de Dell (DUP) en el formato de 32 bits de Microsoft Windows han sido diseñados para ejecutarse en los sistemas operativos de 64 bits de Microsoft Windows. Los paquetes de actualizaciones de Dell (DUP) en el formato de 64 bits de Microsoft Windows solo se ejecutarán en los sistemas operativos de 64 bits de Microsoft Windows. Al seleccionar una actualización de un controlador de dispositivo asegúrese de seleccionar el que sea apropiado para su sistema operativo.
Para garantizar la integridad de su descarga, verifique el valor de la suma de comprobación.
MD5:
112E477AC227DBA02A2CDAF8240C24B4
SHA1:
No disponible
SHA-256:
No disponible

Formato de archivo: Un archivo de GnuPG que contiene una firma criptográfica
File Name: RAID_FRMW_LX_R216022.BIN.sign
Tamaño del archivo: 194 Bytes
Este es un archivo grande. La descarga puede tardar, dependiendo de la velocidad de conexión.
Descripción del formato:
La firma GnuPG para el paquete de actualización para Red Hat Linux se puede usar para autenticar la identidad de Dell en el paquete de actualización para Red Hat Linux correlativo.
Para garantizar la integridad de su descarga, verifique el valor de la suma de comprobación.
MD5:
874E1D2B8086E670730D0873A457644F
SHA1:
No disponible
SHA-256:
No disponible

Formato de archivo: ZipPack externo
File Name: DELL_CERC-6-I-INTEGRATED_A11_R216022.exe
Tamaño del archivo: 1.89 MB
Este es un archivo grande. La descarga puede tardar, dependiendo de la velocidad de conexión.
Descripción del formato:
Este archivo contiene o un conjunto de archivos comprimidos (o zipeados). Descargue el archivo a una carpeta en su disco duro y luego ejecútelo (haga doble clic) para descomprimir el conjunto de archivos. Siga las instrucciones para completar la instalación.
Para garantizar la integridad de su descarga, verifique el valor de la suma de comprobación.
MD5:
9308f538082b21e6ae47885ab19d38e5
SHA1:
a04e333bb06e2a48c293708627e4ad7adbc2fbbe
SHA-256:
No disponible

Formato de archivo: Notas de versiones externas
File Name: R216022.txt
Tamaño del archivo: 14.35 KB
Este es un archivo grande. La descarga puede tardar, dependiendo de la velocidad de conexión.
Descripción del formato:
Este formato de archivo contiene texto sin formato que se puede ver con un editor de texto estándar.
Para garantizar la integridad de su descarga, verifique el valor de la suma de comprobación.
MD5:
0b673803acbc8be9ba23125dd3c139c3
SHA1:
No disponible
SHA-256:
No disponible

Formato de archivo: Paquete de actualización para Red Hat Linux
File Name: RAID_FRMW_LX_R216022.BIN
Tamaño del archivo: 4.45 MB
Este es un archivo grande. La descarga puede tardar, dependiendo de la velocidad de conexión.
Descripción del formato:
Los paquetes de actualización de Dell para Linux se pueden utilizar como aplicaciones independientes que garantizan que se satisfagan los criterios de validación específicos, y luego aplicar una actualización.
Nota: los paquetes de actualización para Linux son de código abierto. Para obtener más detalles, consulte el archivo Léame de los paquetes de actualización de Dell para Linux.
Para garantizar la integridad de su descarga, verifique el valor de la suma de comprobación.
MD5:
6D8A313070F4B739FD73D6462F861A04
SHA1:
No disponible
SHA-256:
No disponible

Al realizar la descarga, acepta los términos del Contrato de licencia de software de Dell. (en ingles)

Detalles adicionales

Mostrar todo | Esconder todo
1. When viewing SATA physical disk properties from Ctrl-R or other management applications, the Vendor Identification will be translated as "ATA" followed by blanks.

2. If all physical disks making up a virtual disk are removed from the system or enclosure, the RAID controller will delete the virtual disk. If the disks are later re-inserted, they will be marked foreign and can be imported using a management application.

3. If a virtual disk is configured with write-back cache enabled and some or all of its physical disks are removed from the system or enclosure, the RAID controller will preserve the virtual disk's write cache. The controller will flush the preserved cache when the physical disks are replaced and the foreign configuration is imported. Any attempt to update controller firmware will be blocked when cache is preserved for a virtual disk.

4. Physical disks determined to contain a foreign configuration are not available for configuration as a new dedicated or global hot spare, or as a member of a new virtual disk. The foreign configuration must be imported or cleared from the physical disk before it may be used as a hot spare or member of a virtual disk. Physical disks with a foreign configuration will not appear on the Create New VD screen in Ctrl-R.

5. Prior to performing a virtual disk migration to another system, the source system must be powered off before removal of the physical disks to preserve the correct virtual disk state. This is not required for the target system and the physical disks may be inserted while the system is powered on or off.

6. The controller restricts the importing of virtual disks that are undergoing RAID Level Migration or Capacity Expansion. Do not interrupt virtual disks that are performing either of these operations because it will disable the ability to import the virtual disk and the data will be unavailable. Dell recommends that the user perform a data backup before starting these operations.

7. EMM changes or drive migrations are not supported during a Capacity Expansion or Raid Level Migration. This may cause the VDs to go offline. Dell recommends the user to perform a data backup before starting these operations.

8. This version of firmware will not ensure complete compatibility with an older version of management applications. OpenManage 5.5 or greater is recommended.

9. It is recommended that the customer upgrade the management application and device driver to the latest version available from Dell at the time of installation of this firmware.

10. Important Information for Update Packages for Microsoft Windows

a. Do not run other applications while executing Dell Update Packages.
b. Do not run storage controller update packages if the controller is in use
by other applications. The firmware upgrade may fail if any of the
RAID controllers in the system are performing I/O background tasks
(consistency checks, background initializations, rebuilds, or
reconstructions). Allow the background tasks to complete before
attempting to upgrade the firmware. Patrol Read tasks will not affect
firmware upgrades.

11. Important Information for Update Packages for Linux

a. Do not run other applications while executing Dell Update Packages.
b. If the following error occurs, "Error while loading shared libraries:
libstdc++.so.5: cannot open shared object file: No such file or
directory", you must install the compatibility libraries. These
libraries can be found on the installation media or online. To install
the compatibility libraries, use the following commands:
"rpm -ih compat-libstdc++-33-3.2.3.-*.i386.rpm" for RHEL 4 or 5
"rpm -ih compat-libstdc++-5.0.7-*.x86_64.rpm" for SLES 10
c. When Update Packages stop abruptly due to a power outage or abnormal
termination, perform the following steps:
- Remove the lock file.
- Type the following command: rm -f /var/lock/.spsetup
- Run the Update Package again to reapply the update.
d. Do not ru
CERC 6/i Integrated
PERC 6/i Integrated Blade
Performing the Firmware Upgrade

NOTE: This initial section of the Installation Instructions applies only to configurations with (greater than) 2TB SEDs.

1. Update the firmware version to this version using preferred method below (Zip Pack, Windows DUP, Linux DUP).
2. Reboot for the new FW take effect
3. Un-assign any (greater than) 2TB SED Dedicated or Global Hot Spares in the configuration. Not all configurations have hot spares.
4. Use CTRL-R or OMSS to issue Instant Secure Erase to all un-configured (greater than) 2TB SED drives (all data in these drives will be lost)
5. Re-assign (greater than) 2TB SED Hot Spares.

Zip pack:

Download
1. Click the Download Now link to download the file.
2. When the File Download window appears, click Save to save the file to your
hard drive.

Extract Files
1. Browse to the location where you downloaded the file and double-click the
new file to unzip the download package
2. Click Continue.
3. Specify the location to unzip the files.
4. Click onthe OK button to extract files.
After the files are extracted the message all files were successfully
unzipped will appear.
5. Click the OK button to exit from the installer.

Installation
1. Copy extracted files to bootable media.
2. Reboot system to bootable media.
3. Execute update.bat to perform flash.
5. After flash is complete, remove bootable media.
4. Reboot system for changes to take effect.


Windows Update Package:

Download
1. Click the "Download Now" link to download the file.
2. When the File Download window appears, click Save to save the file to
your hard drive.

Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window
before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.


Linux Update Package:

Download
1. Click the Download Now linkto download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.

Installation
1. Read over the release information presented by executing the
./FRMW_LX_RXXXXXX.BIN --version command from the shell.
2. Download and install any prerequisites identified in the above step before
proceeding.
3. Run the update by executing ./FRMW_LX_RXXXXXX.BIN from the shell.
4. Follow the remaining prompts to perform the update.

GnuPG Signature of Dell Update Package Instructions for FRMW_LX_RXXXXXX.BIN:

Download
1. Click the Download Now link to download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.

Installation
1. Import the Dell public key. (You only need to do this once on your system.)
2. Verify the Dell Update Package by using its signature file, FRMW_LX_RXXXXXX.BIN.

Ayuda y tutoriales para controladores