Dell PowerVault 220S/221S SES Firmware, v.E.17, A06

已自動安裝 此檔案會在最近更新時自動安裝。如果您遇到任何問題,可以手動下載並重新安裝。
此頁面的內容可能經過電腦自動翻譯。若要提供意見回饋,請填寫頁面底部的表單。
The PV22xS_E17.bin file is the downloadable version of the enclosure firmware that provides management functions for the PowerVault 220S/221S. These functions include SCSI Enclosure Services (SES) and SCSI Accessed Fault-Tolerant Enclosures (SAF-TE) reporting to the host initiator, control of all enclosure LED indicators, and monitoring of all the enclosure's environmental elements.
建議

為您的系統尋找最適合的下載項目

請輸入產品的詳細資料以檢視系統的最新驅動程式資訊

搜尋支援

輸入您的 Dell 產品服務編號或型號

想要尋找您的產品嗎?請輸入產品識別碼。 告訴我怎麼做

此驅動程式不相容

此驅動程式不適用於選取的產品。請選擇其他產品,以重新輸入適用於此驅動程式的產品詳細資料,或前往產品支援頁面,檢視其他產品的所有驅動程式。

尋找更多更新。使用 SupportAssist 為您的裝置尋找所有最新的驅動程式更新。

修復及強化

Firmware E.17 is strictly a maintenance release for PV220S/PV221S. Dell recommends that all PV220S/PV221S be at minimal level of E.16 or greater. Systems having E.16 is not required to upgrade to E.17, which provides the following updates: Removed reading of fans and power supply FRU part numbers to fix manufacturing test issues. FRU (Field Replaceable Units) are also referred to as service part numbers. No impact to customers since service calls always cross reference to the latest available service part number. Add retry operations to read FRUs if it failed to read previously during enclosure initialization.
閱讀更多

繁體中文版

E.17, A06

發佈日期

26 8月 2005

下載類型

韌體

類別

DAS

重要性

建議
Dell Technologies 建議您在下一個排定的更新週期套用此更新。此更新包含的變更可維持整體的系統健全狀況。此更新可確保系統軟體保持在最新狀態並與其他系統模組 (韌體、BIOS、驅動程式及軟體) 相容,並且可能包含其他新功能。
可用的格式 檢視重要資訊

檔案格式: 適用於 MS Windows (32 位元) 的更新套件
檔案名稱: FRMW-R74083.exe
檔案大小: 2.24 MB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
Microsoft Windows 32 位元格式的 Dell 更新套件 (DUP) 經過精心設計,可在 Microsoft Windows 64 位元作業系統上執行。Microsoft Windows 64 位元格式的 Dell 更新套件 (DUP) 只能在 Microsoft Windows 64 位元作業系統上執行。選擇裝置驅動程式更新時,請務必選擇適用您作業系統的更新。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
B898B9D875B654604EEF9C8BE09DB053
SHA1:
不適用
SHA-256:
不適用

檔案格式: 將檔案直接解壓縮至本機磁碟
檔案名稱: FUPG_E17.exe
檔案大小: 48.54 KB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
此檔案格式內含檔案封存,且該封存可能會解壓縮到硬碟上的目錄。接著就可以在該目錄中完成安裝。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
不適用
SHA1:
不適用
SHA-256:
不適用

檔案格式: 適用於 Red Hat Linux 的更新套件
檔案名稱: FRMW-R74083.bin
檔案大小: 2.01 MB
此為大型檔案。視您的連線速度而定,下載可能需要一些時間。
格式說明:
適用於 Linux 的 Dell 更新套件可做為獨立的應用程式,確保符合特定的驗證條件,然後套用更新。
注意:適用於 Linux 的更新套件為開放原始碼套件。請參閱適用於 Linux 的 Dell 更新套件的「讀我」檔案,瞭解詳情。
為了確保下載的完整性,請驗證總和檢查值。
MD5:
B783C566741E5AD223AE1F4008B217AD
SHA1:
不適用
SHA-256:
不適用

當您開始下載,即表示您接受 Dell 軟體授權協定 (英文版) 的條款。

其他詳細資料

顯示全部 | 隱藏全部
Known Limitations:
  1. In Joined bus/Clustering mode, firmware is downloaded to both EMMs automatically (assuming that the second EMM is installed) by failing over and then failing back. In Split bus mode, however, updating firmware on one EMM does not automatically update the other EMM. Therefore, in order to update both EMMs, the user must download directly through the cable to each EMM.

  2. When using Array Manager 3.1.1 (or less) in Clustering mode, EMM firmware can only be upgraded on the primary EMM (the left one when viewing the enclosure from the back). Therefore, in order to update both EMMs, the user must download firmware to each EMM individually.

  3. If the PV22XS is configured with one EMM and one termination module in Joined bus mode, an error message will pop up when upgrading the firmware through Array Manager 3.1.1 (or less). This is an invalid error message in this scenario. If the fans have gone back to normal speed, then the firmware download was successful. To verify this, stop and restart the Disk Management Service. Then you can view the firmware version under the enclosure properties.

  4. Firmware updates to enclosures attached to PERC 2/DC, PERC3/SC/QC/DC/DCL, or any PERC4 array controllers require that Array Manager be at release 3.4 or greater; while PERC 2/QC or PERC 3/Di controllers require that Array Manager be at least 3.5 or greater.

Custom Instructions for FUPG_E17.exe:

Updating Firmware Using Array Manager
(Windows & NetWare)


Dell OpenManage Array Manager software provides a comprehensive storage management solution that enables you to configure and manage local and remote storage attached to a system. Array Manager includes an integrated firmware update utility that can be used with the following operating ystems:

  • Windows 2000 Server and Advanced Server

  • Windows Server 2003

  • Novell NetWare (all Dell-supported versions)


To update the firmware on your PowerVault 22xS storage system using Array Manager:

NOTE: In the following steps, xx refers to the firmware release number.

  1. Stop all I/O activity to the storage system.

  2. Create a directory on your local file system.

  3. Download the FUPG_E.xx.EXE file to a directory on your hard drive. The file downloaded is a self-extracting executable. step 2.

  4. Double-click the FUPG_Exx.exe file to extract the firmware update files to your system's hard drive.

  5. On the host system, click the Start button and select Programs > Dell OpenManage Applications
    > Array Manager > Array Manager Console.

  6. Select Arrays > PERC Subsystem.

  7. Select the controller that is linked to the enclosure you are upgrading.

  8. Right-click the enclosure object and select Download Firmware.

  9. Navigate to the .bin file that was extracted in step 4.

  10. Double-click the .bin file and follow the directions on your screen. When the update is complete, a message appears indicating that the update was successful.

    Note: The firmware update may take up to 5 minutes to complete depending on the server speed. Please allow the appropriate time for the firmware update to complete.

  11. Restart I/O activity to the storage system.



Custom Instructions for FRMW-R74083.exe:

Windows Dell Update Packages Procedure


Dell Update Packages (DUPs) are software utilities provided by Dell to update specific software components on your Dell system. DUPs provide an easy-to-use graphical user interface (GUI) that enables you to apply a software update to either a single system or, remotely, to multiple systems using your organization’s software distribution tools. DUPs run separately from Array Manager, so you can use a DUP if Array Manager is not available on your host system. Dell provides DUPs for the following operating systems:


  • Windows 2000 Server and Advanced Server

  • Windows Server 2003

  • Red Hat Enterprise Linux (Version 2.1)

  • Red Hat Enterprise Linux (Version 3) for Intel x86


Windows DUP Update Procedure

The following procedure updates the firmware on a PowerVault 22xS storage system that is attached to a host system that is running the 32-bit version of Windows 2000 Server, Advanced Server, or Windows Server 2003, without Array Manager.
  1. Stop all I/O activity to the storage system.

  2. Create a directory on your local file system.

  3. Download the executable Windows DUP package file (PV220s-221s-FRMW-Rxxxxx.exe, where Rxxxxx indicates the release) from the Dell Support website at support.dell.com and save the file to the directory you created in step 2.

  4. Double-click the downloaded file to uncompress the file and start the update.

  5. When prompted, click Install to update the firmware. When the update is complete, a message appears indicating that the update was successful.

  6. Restart I/O activity to the storage system.


Custom Instructions for FRMW-R74083.bin:

Linux Dell Update Packages


驅動程式說明與教學課程