Dell SAS 6/iR Adapter, v.00.25.47.00.06.22.03.00 , A04

Dell Sas6/iR Adapter Firmware Release; Package Version: 00.25.47.00.06.22.03.00

Fixes & Enhancements

BIOS - 06.22.03.00
NEW FUNCTIONALITY: None.
DEFECT FIXES:
-Implements a change to allow some RAID1 volumes created with earlier
SAS 6/iR FW revisions to be migrated to controllers with this FW revision.
- Implements a change to order the controller list based on defined
controller type instead of static chip-based references
- Updates verify functionality to allow user to escape once
Reassign All has been selected and drive is no longer responding.
- Removes rescan for devices on any keystroke in view array screen.
Rescan will now only be performed on Alt+N keystroke.


FIRMWARE - 00.25.47.00
NEW FUNCTIONALITY:
- Modifies coercion of RAID volumes to align with PERC. This facilitates
migration of SAS6 RAID volumes to PERC6.
DEFECT FIXES:
-Implements a change to allow some RAID1 volumes created with earlier
SAS 6/iR FW Revisions to be migrated controllers with this FW revision or later.
-Improves robustness in handling Task Management events during heavy IO
-Implements a change to correct an issue with initialization of interposer
attached SATA drives where link to the drive could be left in a state where
it was possible that I/Os could be timed out and have to be retried by
the host.

Version

Version 00.25.47.00.06.22.03.00, A04

Category

SAS RAID

Release date

06 Dec 2011

Last Updated

25 May 2013

Importance

Available formats

File Format:Hard-Drive
File Name:DELL_SAS-6-IR-ADAPTER_A04_R197382.exe
Download Type:HTTP
File Size: 563 KB
Format Description:This file contains a compressed (or zipped) set of files. Download the file to a folder on your hard drive, and then run (double-click) it to unzip the set of files. Follow the instructions to complete the installation.
To ensure the integrity of your download, please verify the checksum value.
MD5:
34a3cf38ec1f9c10ecfd2b4ac32a6b9d
SHA1:
2c1fac888775182b63f461c1da1df756b6533619
SHA-256:
b065927408cd8cf1e4afd61593cdc146dced2dda1453f597cb1f7773de8d3c6f
File Format:Update Package for Microsoft® Windows®
File Name:SAS-RAID_Firmware_6T2TK_WN32_00.25.47.00.06.22.03.00_A04.EXE
Download Type:HTTP
File Size: 5 MB
Format Description:Dell Update Packages (DUP) in Microsoft Windows 32bit format have been designed to run on Microsoft Windows 64bit Operating Systems. Dell Update Packages (DUP) in Microsoft Windows 64bit format will only run on Microsoft Windows 64bit Operating Systems. When selecting a device driver update be sure to select the one that is appropriate for your operating system.
To ensure the integrity of your download, please verify the checksum value.
MD5:
6187d1acd2a29a1b0bd68d9ed4789a7d
SHA1:
5fcdb8dbb89c95962ec355814802c7aa36fdd3f6
SHA-256:
Not available
File Format:Update Package for Red Hat Linux
File Name:SAS-RAID_Firmware_6T2TK_LN32_00.25.47.00.06.22.03.00_A04.BIN
Download Type:HTTP
File Size: 3 MB
Format Description:Dell Update Packages for Linux can be used as stand-alone applications that ensure that specific validation criteria are met, then apply an update.
Note: Update Packages for Linux are open source. See the Dell Update Packages for Linux Readme for details.
To ensure the integrity of your download, please verify the checksum value.
MD5:
4d4ee10cd8f3ae46527f70a38e17169f
SHA1:
4265f3a8b30dd24f83790d919e306d39c1a3a9ae
SHA-256:
Not available
File Format:Rel-Notes-Text
File Name:R197382.txt
Download Type:HTTP
File Size: 7 KB
Format Description:This file format contains plain text which can be viewed with a standard text editor.
To ensure the integrity of your download, please verify the checksum value.
MD5:
4b11813d93d89a8fe4b925773e0581a2
SHA1:
Not available
SHA-256:
Not available
File Format:GnuPG Signature for Linux Update Package
File Name:SAS-RAID_Firmware_6T2TK_LN32_00.25.47.00.06.22.03.00_A04.BIN.sign
Download Type:HTTP
File Size: 0.2 KB
Format Description:The GnuPG signature for Red Hat Linux Update Package can be used to authenticate Dell's identity in the correlated Red Hat Linux Update Package.
To ensure the integrity of your download, please verify the checksum value.
MD5:
09d199c003966038a643403451616101
SHA1:
960216fb1a68cf23c8e6b5b895696e31a80e85f2
SHA-256:
Not available

By downloading, you accept the terms of the Dell Software License Agreement.

Applies to
SAS 6/iR Adapter
SAS 6/IR Integrated Blades
Installation instructions
Performing the Firmware Upgrade

NOTE: This initial section of the Installation Instructions applies only to configurations with (greater than) 2TB SEDs.

1. Update the firmware version to this version using preferred method below (Zip Pack, Windows DUP, Linux DUP).
2. Reboot for the new FW take effect
3. Un-assign any (greater than) 2TB SED Dedicated or Global Hot Spares in the configuration. Not all configurations have hot spares.
4. Use CTRL-R or OMSS to issue Instant Secure Erase to all un-configured (greater than) 2TB SED drives (all data in these drives will be lost)
5. Re-assign (greater than) 2TB SED Hot Spares.

Zip pack:

Download
1. Click the Download Now link to download the file.
2. When the File Download window appears, click Save to save the file to your
hard drive.

Extract Files
1. Browse to the location where you downloaded the file and double-click the
new file to unzip the download package
2. Click Continue.
3. Specify the location to unzip the files.
4. Click onthe OK button to extract files.
After the files are extracted the message all files were successfully
unzipped will appear.
5. Click the OK button to exit from the installer.

Installation
1. Copy extracted files to bootable media.
2. Reboot system to bootable media.
3. Execute update.bat to perform flash.
5. After flash is complete, remove bootable media.
4. Reboot system for changes to take effect.


Windows Update Package:

Download
1. Click the "Download Now" link to download the file.
2. When the File Download window appears, click Save to save the file to
your hard drive.

Installation
1. Browse to the location where you downloaded the file and double-click the new file.
2. Read over the release information presented in the dialog window.
3. Download and install any prerequisites identified in the dialog window
before proceeding.
4. Click the Install button.
5. Follow the remaining prompts to perform the update.


Linux Update Package:

Download
1. Click the Download Now linkto download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.

Installation
1. Read over the release information presented by executing the
./FRMW_LX_RXXXXXX.BIN --version command from the shell.
2. Download and install any prerequisites identified in the above step before
proceeding.
3. Run the update by executing ./FRMW_LX_RXXXXXX.BIN from the shell.
4. Follow the remaining prompts to perform the update.

GnuPG Signature of Dell Update Package Instructions for FRMW_LX_RXXXXXX.BIN:

Download
1. Click the Download Now link to download the file.
2. When the File Download window appears, click Save to save the file to your hard drive.

Installation
1. Import the Dell public key. (You only need to do this once on your system.)
2. Verify the Dell Update Package by using its signature file, FRMW_LX_RXXXXXX.BIN.

Reboot will be required
x
Warning: Do not turn off your computer or disconnect from your power source while updating the BIOS or you may harm your computer. During the update, your computer will restart and you will briefly see a black screen.

This driver has been tested by both the independent software vendor (ISV) and Dell on the operating systems, graphics cards, and application supported by your device to ensure maximum compatibility and performance. Details

Dell recommends applying this update during your next scheduled update cycle. The update contains feature enhancements or changes that will help keep your system software current and compatible with other system modules (firmware, BIOS, drivers and software).