Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

SC 存储客户通知:Dell Storage Manager 服务器设置失败,并显示开启 MPIO 时出错

Summary: 使用Windows Server 2016时,在Dell Storage Manager中收到启用MPIO时的错误信息。

This article may have been automatically translated. If you have any feedback regarding its quality, please let us know using the form at the bottom of this page.

Article Content


Symptoms

在Windows Server 2016中,设置为指明某功能是否启用的标记在重新启动前未设置。  在Dell Storage Manager中,运行Server Setup(服务器设置)向导时,由于未设置标记,将出现以下错误消息。  

在本地主机上打开 MPIO 时出错...
 

Cause

Resolution

解决办法:
  1. 首先安装运行Windows Server 2016的MPIO;
  2. 重新启动服务器;
  3. 通过以下任一方式验证MPIO是否已安装:
    1. 运行 PowerShell 命令:
       get-windowsfeature multipath-io
        “Install State”必须显示为“Installed”。
    2. 检查Windows控制面板中是否有MPIO 
  4. 使用Dell Storage Manager并运行“Server Setup”(服务器设置)向导。 
如果遇到上述错误,请重新启动服务器并重新运行向导。

分辨率:
修复程序位于 2018 年 3 月更新 3B 包 KB 4088787 中(这是一个累积包)。
要检查已安装的更新,请使用 PowerShell 命令: 
Get-HotFix |ft HotfixID, InstalledOn

Article Properties


Affected Product
Compellent (SC, SCv & FS Series), Dell Compellent SC4020, Dell Storage SC8000, Dell Compellent Series 40, Dell Storage SCv2000, Dell Storage SCv2020, Dell Storage SCv2080, Dell Storage SC5020, Dell Storage SC5020F, Dell Storage SC7020 , Dell Storage SC7020F, Dell Storage SC9000, Dell Storage SCv3000, Dell Storage SCv3020 ...
Last Published Date

16 May 2024

Version

4

Article Type

Solution