|

Equallogic PS4110

intel® xeon™
Back to Previous Page

Next-generation 10GbE iSCSI SAN arrays designed for growing environments

EqualLogic PS4110e Storage System

PS4110E

Improve storage capacity, performance and connectivity for your small or midsize business with cost-effective EqualLogic™ PS4110E 10GbE iSCSI SAN arrays.

View Details
EqualLogic PS4110xv 3.5" Storage System

PS4110XV 3.5”

Enhance your enterprise data center with the 10GbE performance, high capacity and cost-effectiveness of Dell™ EqualLogic™ PS4110XV 3.5” 10GbE iSCSI arrays.

View Details

GREAT FOR

Small to midsize businesses and remote or branch offices seeking cost-effective, high-capacity 10GbE iSCSI SAN arrays for their growing storage needs.

Helping control costs when building high-performance, high-capacity enterprise data centers

Product Configurations

Storage Controllers
Dual controllers with 4GB non-volatile memory per controller

Hard Disk Drives
Twelve (12) 7.2K NL-SAS hot-pluggable hard drives.

Drive Capacities
3.5" 7.2K RPM NL-SAS drives available in 1TB, 2TB or 3TB

System Capacities
12TB using twelve (12) 1TB NL-SAS disk drives
24TB using twelve (12) 2TB NL-SAS disk drives
36TB using twelve (12) 3TB NL-SAS disk drives
Storage Controllers
Dual controllers with 4GB non-volatile memory per controller

Hard Disk Drives
Twelve (12) 7.2K NL-SAS hot-pluggable hard drives.

Drive Capacities
3.5" 7.2K RPM NL-SAS drives available in 1TB, 2TB or 3TB

System Capacities
12TB using twelve (12) 1TB NL-SAS disk drives
24TB using twelve (12) 2TB NL-SAS disk drives
36TB using twelve (12) 3TB NL-SAS disk drives

Technical Highlights

Volumes
Up to 256

Snapshots
128 per volume / up to 2,048 total per group

Volume Connections
Up to 512 per pool / 1024 per group

Host Protocol
Any standards-compliant iSCSI initiator

Operating Systems Supported

Microsoft® Windows Server® including Hyper-V®
VMware® ESX Server™
Red Hat® Enterprise Linux® (RHEL)
SUSE® Enterprise Linux® (SLES)
Oracle® Linux
Oracle® Solaris™
IBM® AIX®
HP-UX
Mac OS® X
Citrix® XenServer®
Novell® NetWare®

For a complete list of supported OS versions including software initiators, NICs/CNAs, and HBAs, see the EqualLogic Compatibility Matrix on http://en.community.dell.com/techcenter/storage/w/wiki/2661.equallogic-compatibility-matrix-07262013.aspx.

RAID Support
RAID 5, RAID 6, RAID 10, and RAID 50*

10GbE Network Interfaces
Management network: One 100BASE-TX dedicated management port per controller
Interface ports: One 10GBASE-T with RJ45 and one 10GbE SFP+ for fibre or twin-ax copper cabling per controller

TCP Network Support
IPv4, IPv6 core support

Expansion Option
Can be combined with other EqualLogic PS Series arrays in the same SAN group, online. A maximum of two (2) PS4xx0 arrays can be in a group.

Volumes
Up to 256

Snapshots
128 per volume / up to 2,048 total per group

Volume Connections
Up to 512 per pool / 1024 per group

Host Protocol
Any standards-compliant iSCSI initiator

Operating Systems Supported

Microsoft® Windows Server® including Hyper-V®
VMware® ESX Server™
Red Hat® Enterprise Linux® (RHEL)
SUSE® Enterprise Linux® (SLES)
Oracle® Linux
Oracle® Solaris™
IBM® AIX®
HP-UX
Mac OS® X
Citrix® XenServer®
Novell® NetWare®

For a complete list of supported OS versions including software initiators, NICs/CNAs, and HBAs, see the EqualLogic Compatibility Matrix on http://en.community.dell.com/techcenter/storage/w/wiki/2661.equallogic-compatibility-matrix-07262013.aspx.

RAID Support
RAID 5, RAID 6, RAID 10, and RAID 50*

10GbE Network Interfaces
Management network: One 100BASE-TX dedicated management port per controller
Interface ports: One 10GBASE-T with RJ45 and one 10GbE SFP+ for fibre or twin-ax copper cabling per controller

TCP Network Support
IPv4, IPv6 core support

Expansion Option
Can be combined with other EqualLogic PS Series arrays in the same SAN group, online. A maximum of two (2) PS4xx0 arrays can be in a group.

Reliability

Redundant hot-swappable controllers with vertical port sharing
Hot-swappable disks and power supplies
Redundant hot-swappable controllers with vertical port sharing
Hot-swappable disks and power supplies

Enclosure Monitoring System

Automatic spare configuration and utilization
SMART
Automatic bad block replacement
Auto-Stat Disk Monitoring System (ADMS) to monitor health of data on disk drives
Automatic spare configuration and utilization
SMART
Automatic bad block replacement
Auto-Stat Disk Monitoring System (ADMS) to monitor health of data on disk drives

Management

SAN Headquarters multi-group performance and event monitoring tool
Serial console
Ability to configure a separate management network
SNMP, telnet, SSH, HTTP, Web (SSL), host scripting
Multi-administrator support
SAN Headquarters multi-group performance and event monitoring tool
Serial console
Ability to configure a separate management network
SNMP, telnet, SSH, HTTP, Web (SSL), host scripting
Multi-administrator support

Security

CHAP authentication
Access control for iSCSI
Access control for management interfaces including RADIUS support
CHAP authentication
Access control for iSCSI
Access control for management interfaces including RADIUS support

Notification Methods

SNMP traps, e-mail, syslogSNMP traps, e-mail, syslog

Power

AC voltage: 100-240 VAC ±10% single phase
700 W (max, total), +5V up to 155W; +12V up to 624W; +5Vsb up to 10W
Frequency: 50/60 Hz
Power factor: 0.98 (minimum)
Power supplies: Dual 700 W
AC voltage: 100-240 VAC ±10% single phase
700 W (max, total), +5V up to 155W; +12V up to 624W; +5Vsb up to 10W
Frequency: 50/60 Hz
Power factor: 0.98 (minimum)
Power supplies: Dual 700 W

Chassis

Height: 2U / 8.68 cm (3.41 inches)
Width: 44.63 cm (17.57 inches)
Depth: 59.4 cm (23.4 inches)
Weight: 27.67 kg (61 lbs)

Packaged physical: Length: 851 cm (33.50 inches) Width: 629 cm (24.75 inches) Depth: 395 cm (15.56 inches)
Packaged weight: 40.8261 Kg (90 lb)

Rack Support
ReadyRails™ II static rails for tool-less mounting in 4-post racks with square or unthreaded round holes or tooled mounting in 4-post threaded-hole racks
Height: 2U / 8.68 cm (3.41 inches)
Width: 44.63 cm (17.57 inches)
Depth: 59.4 cm (23.4 inches)
Weight: 27.67 kg (61 lbs)

Packaged physical: Length: 851 cm (33.50 inches) Width: 629 cm (24.75 inches) Depth: 395 cm (15.56 inches)
Packaged weight: 40.8261 Kg (90 lb)

Rack Support
ReadyRails™ II static rails for tool-less mounting in 4-post racks with square or unthreaded round holes or tooled mounting in 4-post threaded-hole racks

Environmental Operating Conditions

Temperature range: 5° to 40°C (41° to 104°F)
Storage temperature: –40° to 65°C (–40° to 149°F)
Altitude: For altitudes above 2950 feet, the maximum operating temperature is derated 1ºF/550 ft.
Relative humidity: 20% to 80% (noncondensing) with a maximum humidity gradation of 10% per hour
Shock: Half-sine shock 31G +/- 5% with a pulse duration of 2.6ms +/- 10% in operational orientations only
Vibration: 0.26 Grms (5 to 350 Hz) for 5 minutes in operational orientations
Acoustics Category 4: <=7.2 bels at 23C +/- 2C
Air Quality: Airborne contaminant level of G1 or lower as defined by ISA-S71.04-1985
Temperature range: 5° to 40°C (41° to 104°F)
Storage temperature: –40° to 65°C (–40° to 149°F)
Altitude: For altitudes above 2950 feet, the maximum operating temperature is derated 1ºF/550 ft.
Relative humidity: 20% to 80% (noncondensing) with a maximum humidity gradation of 10% per hour
Shock: Half-sine shock 31G +/- 5% with a pulse duration of 2.6ms +/- 10% in operational orientations only
Vibration: 0.26 Grms (5 to 350 Hz) for 5 minutes in operational orientations
Acoustics Category 4: <=7.2 bels at 23C +/- 2C
Air Quality: Airborne contaminant level of G1 or lower as defined by ISA-S71.04-1985

Regulatory

Regulatory Model: E03J
Regulatory Type: E03J001

Product Safety, EMC and Environmental Datasheets
Dell Regulatory Compliance Home Page
Dell and the Environment


ENERGY STAR®
The Dell PS4110 series arrays have earned the ENERGY STAR Data Center Storage designation. Click Here to learn more about the ENERGY STAR Storage 1.0 designation.
ENERGY STAR
Regulatory Model: E03J
Regulatory Type: E03J001

Product Safety, EMC and Environmental Datasheets
Dell Regulatory Compliance Home Page
Dell and the Environment


ENERGY STAR®
The Dell PS4110 series arrays have earned the ENERGY STAR Data Center Storage designation. Click Here to learn more about the ENERGY STAR Storage 1.0 designation.
ENERGY STAR
close
 
 
CS01