|

Dell PowerEdge Rack Servers

intel® xeon™
Back to Previous Page
Reset Chart

Viewing 1-4 of 14

Businesses with multiple servers or limited square footage or storage space

Poweredge R220

PowerEdge R220

Save space with a short-depth chassis, save time with intuitive management using a quiet, 1U 1-socket server.

View Details
PowerEdge R320 Server

New PowerEdge R320 Rack Server

Experience enterprise-class features in the rack-optimized 1U PowerEdge™ R320 server — ideal for your core business applications.

View Details
Dell PowerEdge R415 Rack Server

PowerEdge R415

The PowerEdge R415 is an AMD processor-based two-socket, 1U rack server for small and medium business and data center functions such as IT infrastructure, email, select HPC usage and virtualization needs.

View Details
PowerEdge R420 Rack Server

PowerEdge R420

Get an energy-efficient, dense 1U server for your applications with the PowerEdge™ R420, featuring next-generation processing and flexible I/O options.

View Details
Dell PowerEdge R515 Rack Server

PowerEdge R515

The PowerEdge™ R515 is an AMD processor-based 2-socket, 2U rack server that is great for department, branch or small business database tasks, email, virtualisation, workload consolidation and business applications with large storage requirements.

View Details
PowerEdge R520 Rack Server

New PowerEdge R520 Rack Server

Power through data-intensive applications and easily scale for growing utilization with the next-generation PowerEdge™ R520.

View Details
PowerEdge R620 Rack Server

PowerEdge R620

Maximize computing power without compromise in space-sensitive environments with the Dell™ PowerEdge™ R620.

View Details
PowerEdge R715 Rack Server

PowerEdge R715

The PowerEdge™ R715 is an AMD processor-based 2-socket, 2U rack server ideal for customers seeking value, systems management, and great price for performance in workload consolidation, virtualisation, medium databases and other applications.

View Details
PowerEdge R720 Rack Server

PowerEdge R720

Keep pace with the exponential change of the virtual age using the state-of-the-art feature flexibility of the PowerEdge™ R720.

View Details
PowerEdge R720xd Rack Server

PowerEdge R720xd

Easily scale for massive data growth with the excellent storage capacity, memory density and I/O capabilities of the PowerEdge™ R720xd rack server.

View Details
PowerEdge R815 Rack Server

PowerEdge 11G R815

Customers seeking the ideal combination of value, systems management and performance in virtualization, medium databases, high-performance computing (HPC) and other highly threaded application implementations.

View Details
PowerEdge R820 Rack Server

New PowerEdge R820 Rack Server

Manage data overload and expanding virtual environments with the extreme processing power and massive memory density of the Dell™ PowerEdge™ R820.

View Details
PowerEdge R910 Rack Server

PowerEdge R910

The PowerEdge™ R910 is an Intel® processor-based 4-socket, 4U rack server for mission-critical applications in corporate data centers and workloads needing the highest performance, reliability and I/O scalability.

View Details
PowerEdge R920

PowerEdge R920

Drive large databases, ERP, HPC and other demanding workloads with 4-socket performance, scalable memory and powerful IO.

View Details

Desktop consolidation and virtualization, productivity and collaboration applications, mail and messaging, file sharing and data protection.

Departmental web servers, smaller scale hosting and virtualization, retail servers and other remote, branch or small-to-midsize business applications.

The PowerEdge R415 is an AMD processor-based two-socket, 1U rack server suited for small and medium businesses and data centers run-the-business functions such as IT infrastructure, file/print, Web, email, select HPC usage and entry virtualization needs.

Departmental, remote-site and space-constrained environments requiring file and print, ecommerce, web hosting, HPC and small-scale virtualization.

The PowerEdge™ R515 is an AMD processor-based 2-socket, 2U rack server that is great for department, branch or small business database tasks, email, virtualisation, workload consolidation and business applications with large storage requirements.

Core business applications, such as email and workgroup collaboration as well as mid-size databases and virtualized environments.

Dense virtualization, high-performance computing (HPC) and web hosting

The PowerEdge™ R715 is an AMD processor-based 2-socket, 2U rack server ideal for customers seeking value, systems management, and great price for performance in workload consolidation, virtualisation, medium databases and other applications.

Virtualization, databases, decision support, e-commerce, and collaboration workloads for midsize and large enterprises.

Large email deployments, Hadoop distributed computing, large-scale databases, medical imaging and other data-intensive tasks.

Customers seeking the ideal combination of value, systems management and performance in virtualization, medium databases, high-performance computing (HPC) and other highly threaded application implementations.

Dense virtualization, scalable database applications and other compute-intensive, mission-critical workloads for midsize and large enterprises.

The PowerEdge™ R910 is an Intel® processor-based 4-socket, 4U rack server for mission-critical applications in corporate data centers and workloads needing the highest performance, reliability and I/O scalability.

Running mission-critical applications in mid-size- and large-enterprise deployments or migrating from outdated UNIX/RISC infrastructures.

Processor

Intel Xeon® processor E3-1200 v3 product family
Intel Pentium®
Intel Celeron®
Intel Core® I3-4130
Intel® Xeon® processor E5-2400 and E5-2400 v2 product families
Intel Xeon processor E5-1410
Intel Pentium® processor 1400 product family

Processor sockets
1

Cache
2.5MB per core; core options: 4, 6, 8, 10

Internal interconnect
Intel DMI 2.0
AMD Opteron™ 4100, 4200 and 4300 series processorsIntel® Xeon® processor E5-2400 and E5-2400 v2 product families

Processor sockets:
2

Internal interconnect:
Intel QuickPath Interconnect (QPI) link: 6.4GT/s; 7.2GT/s; 8.0 GT/s

Cache:
2.5MB per core; core options: 4, 6, 8, 10
AMD Opteron™ 4100, 4200 and 4300 series processorsIntel® Xeon® processor E5-2400 and E5-2400 v2 product families

Processor sockets:
2

Internal interconnect:
Intel QuickPath Interconnect (QPI) link: 6.4GT/s; 7.2GT/s; 8.0 GT/s

Cache:
2.5MB per core; core options: 4, 6, 8, 10
Intel® Xeon® processor E5-2600 or E5-2600 v2 product family

Processor Socket:
2

Internal Interconnect:
2 x Intel QuickPath Interconnect (QPI); 6.4 GT/s; 7.2 GT/s; 8.0 GT/s

Cache:
2.5MB per core; core options: 4, 6, 8, 10, 12
AMD® Opteron® 6100 series processors based on AMD Opteron 6000 series platformIntel® Xeon® processor E5-2600 or E5-2600v2 product family

Processor socket:
2

Internal Interconnect:
2 x Intel QuickPath Interconnect (QPI) links; 6.4 GT/s; 7.2 GT/s; 8.0 GT/s

Cache:
2.5MB per core; core options: 4, 6, 8, 10, 12

Intel® Xeon® processor E5-2600 or E5-2600 v2 product family

Processor Sockets:
2

Internal Interconnect:
2 x Intel QuickPath Interconnect (QPI) links; 6.4 GT/s; 7.2 GT/s; 8.0 GT/s

Cache:
2.5MB per core; core options: 4, 6, 8, 10, 12

AMD® Opteron® 6100 series processors based on AMD Opteron 6000 series platformIntel® Xeon® processor E5-4600 product family

Processor sockets:
4

Internal interconnect:
2 x Intel QuickPath Interconnect (QPI) links; 6.4 GT/s; 7.2 GT/s; 8.0 GT/s

Cache:
2.5MB per core; core options: 4, 6, 8

Form factor:
2U rack

Up to four, eight-core Intel® Xeon® processors 7500 series
Up to four, ten-core Intel® Xeon® processors E7-2800, E7-4800 and E7-8800 product family
Intel® Xeon® processor E7-4800 v2 and E7-8800 v2 product families (up to 4);
Intel Xeon processor E7-2800 v2 product family (up to 2)

Operating System

Microsoft Windows Server 2008 R2 SP1
Microsoft Windows Server 2012
Microsoft Windows Server 2012 R2
Novell® SUSE® Linux Enterprise Server
Red Hat® Enterprise Linux®
For more information on specific versions and additions, visit Dell.com/OSsupport
Microsoft® Windows Server® 2012
Microsoft Windows Server 2012 Essentials
Microsoft Windows Server 2008 R2 SP1, x64 (includes Hyper-V®)
Novell® SUSE® Linux Enterprise Server
Red Hat® Enterprise Linux®
Virtualization options:
Citrix® XenServer®
VMware® vSphere® ESXi ™
Red Hat Enterprise Virtualization®
Microsoft® Windows® Small Business Server 2011
Microsoft® Windows® Small Business Server 2008
Microsoft® Windows Server® 2008 SP2, x86/x64 (x64 includes Hyper-V™ )
Microsoft® Windows Server® 2008 R2 SP1, x64 (includes Hyper-V™ v2)
Microsoft® Windows® HPC Server 2008
Novell® SUSE® Linux® Enterprise Server
Red Hat® Enterprise Linux®
Virtualization Options:
Citrix® XenServer®
VMware® vSphere™ Version 4.1 (including ESX 4.1/ESXi 41.)

For more information on the specific versions and additions, visit www.dell.com/OSsupport.
Microsoft® Windows Server® 2012
Microsoft Windows Server 2008 R2 SP1, x64 (includes Hyper-V®)
Novell® SUSE® Linux Enterprise Server
Red Hat® Enterprise Linux®
Virtualization options:
Citrix® XenServer®
VMware® vSphere® ESXi ™
Red Hat Enterprise Virtualization®
Microsoft® Windows® Small Business Server 2011
Microsoft® Windows® Small Business Server 2008
Microsoft® Windows Server® 2008 SP2, x86/x64 (x64 includes Hyper-V™)
Microsoft® Windows Server® 2008 R2 SP1, x64 (includes Hyper-V™ v2)
Microsoft® Windows® HPC Server 2008
Novell® SUSE® Linux® Enterprise Server
Red Hat® Enterprise Linux®

Virtualisation Options:
Citrix® XenServer™
VMware® vSphere™ 4.1 (including VMware ESX® 4.1 or VMware ESXi™ 4.1)

For more information on the specific versions and additions, visit www.dell.com/OSsupport.
Microsoft® Windows Server® 2012
Microsoft Windows Server 2008 R2 SP1, x64 (includes Hyper-V®)
Novell® SUSE® Linux Enterprise Server
Red Hat® Enterprise Linux®
Virtualization options:
Citrix® XenServer®
VMware® vSphere® ESXi ™
Red Hat Enterprise Virtualization®
Microsoft® Windows Server® 2012
Microsoft Windows Server 2008 R2 SP1, x64 (includes Hyper-V®)
Novell® SUSE® Linux Enterprise Server
Red Hat® Enterprise Linux®
Virtualization options:
Citrix® XenServer®
VMware® vSphere® ESXi ™
Red Hat Enterprise Virtualization®
Microsoft® Windows® Small Business Server 2011
Microsoft® Windows Server® 2003 R2 SP2, x86/x64
Microsoft® Windows Server® 2008 SP2, x86/x64 (x64 includes Hyper-V™ )
Microsoft® Windows Server® 2008 R2 SP1, x64 (includes Hyper-V™ v2)
Windows® HPC Server 2008 R2
Novell® SUSE® Linux® Enterprise Server
Red Hat® Enterprise Linux®
Oracle® Solaris™
Virtualization Options:
Citrix® XenServer™
VMware® vSphere™ 4.1 (including VMware ESX® 4.1 or VMware ESXi™ 4.1)

For more information on the specific versions and additions, visit www.dell.com/OSsupport.
Microsoft® Windows Server® 2012
Microsoft Windows Server 2008 R2 SP1, x64 (includes Hyper-V®)
Novell® SUSE® Linux Enterprise Server
Red Hat® Enterprise Linux®
Virtualization options:
Citrix® XenServer®
VMware® vSphere® ESXi ™
Red Hat Enterprise Virtualization®
Microsoft® Windows Server® 2012
Microsoft Windows Server 2008 R2 SP1, x64 (includes Hyper-V®)
Novell® SUSE® Linux Enterprise Server
Red Hat® Enterprise Linux®
Virtualization options:
Citrix® XenServer®
VMware® vSphere® ESXi ™
Red Hat Enterprise Virtualization®
Microsoft® Windows Server® 2008 SP2, x86/x64 (x64 includes Hyper-V™ )
Microsoft® Windows Server® 2008 R2 SP1, x64 (includes Hyper-V™ v2)
Windows® HPC Server 2008 R2
Novell® SUSE® Linux® Enterprise Server
Red Hat® Enterprise Linux®
Oracle® Solaris™
Virtualization Options:
Citrix® XenServer™
VMware® vSphere™ 4.1 (including VMware ESX® 4.1 or VMware ESXi™ 4.1)

For more information on the specific versions and additions, visit www.dell.com/OSsupport.
Microsoft® Windows Server® 2012
Microsoft Windows Server 2008 R2 SP1, x64 (includes Hyper-V®)
Novell® SUSE® Linux Enterprise Server
Red Hat® Enterprise Linux®
Virtualization options:
Citrix® XenServer®
VMware® vSphere® ESXi ™
Red Hat Enterprise Virtualization®
Microsoft® Windows Server® 2008 SP2, x86/x64 (x64 includes Hyper-V™ )
Microsoft® Windows Server® 2008 R2 SP1, x64 (includes Hyper-V™ v2)
Microsoft® Windows® HPC Server 2008
Novell® SUSE® Linux® Enterprise Server
Red Hat® Enterprise Linux®
Oracle® Solaris™
Virtualization Options:
VMware® vSphere™ 4.1 (including VMware ESX® 4.1 or VMware ESXi™ 4.1)

For more information on the specific versions and additions, visit www.dell.com/OSsupport.
Microsoft® Windows Server® 2012 R2 (includes Hyper-V®)
Microsoft Windows Server 2012 (includes Hyper-V)
Novell® SUSE® Linux Enterprise Server
Red Hat® Enterprise Linux®
VMware vSphere® ESXi™

Chipset

Intel C222Intel C602AMD (SR5670 and SP5100)Intel C602AMD (SR5670 and SP5100)Intel C602Intel C602AMD (SR5650, SR5670 and SP5100)Intel C602Intel C602AMD (SR5650, SR5670 and SP5100)Intel C602Intel® E 7510Intel C602J

Memory*

Memory DIMMs
4x DDR3 UDIMMs w/ECC
1600MT/s

Min/Max RAM
4GB/32GB
Up to 192GB (6 DIMM slots) 2GB/4GB/8GB/16GB/32GB DDR3 up to 1600MT/sUp to 64GB (8 DIMM slots) 1GB/ 2GB/ 4GB/ 8GB 1333MHz (16GB coming soon)Up to 384GB (12 DIMM slots) 2GB/4GB/8GB/16GB/32GB DDR3 up to 1600MT/sUp to 256GB (8 DIMM slots): 1GB/2GB/4GB/8GB/16GB/32GB DDR3 up to 1600MT/sUp to 384GB (12 DIMM slots) 2GB/4GB/8GB/16GB/32GB DDR3 up to 1600MT/sUp to 1.5TB (24 DIMM slots) 2GB/4GB/8GB/16GB/32GB/64GB DDR3 up to 1866MT/sUp to 512GB (16 DIMM slots) 1GB/2GB/4GB/8GB/16GB/32GB DDR3 up to 1600MT/sUp to 1.5TB (24 DIMM slots) 2GB/4GB/8GB/16GB/32GB/64GB DDR3 up to 1866MT/sUp to 1.5TB (24 DIMM slots) 2GB/4GB/8GB/16GB/32GB/64GB DDR3 up to 1866MT/s
Up to 512GB (32 DIMM Slots): 1GB/2GB/4GB/8GB/16GB 1333MHzUp to 3TB (48 DIMM slots) 4GB/8GB/16GB/32GB/64GB DDR3 up to 1866MT/sUp to 2TB (64 DIMM slots) 2GB/4GB/8GB/16GB/32GB DDR3 up to 1333MT/sUp to 6TB (96 DIMM slots):4GB/8GB/16GB/32GB/64GB DDR3L, RDIMM, LR-DIMM up to 1600MT/s

Storage

2 x 3.5” or 2 x 2.5”
Default SATA; Optional SAS and SSD
Maximum internal storage
Up to 16TB

Hard drives
Hot-plug hard drive options:
2.5” SATA, nearline SAS, SAS (15K, 10K), SAS SSD, SATA SSD, SAS 512n (15K) 
3.5” SATA, nearline SAS, SAS (15K)

Cabled hard drive options:
3.5” SATA, nearline SAS, SAS (15K)
Self-encrypting drives available
Hot-plug Hard Drive Options:
2.5" SATA SSD, SAS (10K)
3.5" SAS (15K), Near Line SAS (7.2K), SATA (7.2K)

Cabled Hard Drive Options:
3.5" SAS (15K), Near Line SAS (7.2K), SATA (7.2K)

Maximum Internal Storage:
Up to 12TB

External Storage:
For information about Dell external storage options, visit Dell.com/Storage.
Maximum internal storage:
Up to 16TB

Hot-plug hard drive options:
2.5” SATA, nearline SAS, SAS (15K, 10K), SAS SSD, SATA SSD, SAS 512n (15K)
3.5” SATA, nearline SAS, SAS (15K)
Self-encrypting drives available

Cabled hard drive options:
3.5” SATA, nearline SAS, SAS (15K)
Hot-plug Hard Drive Options:
2.5" SAS SSD, SATA SSD, SAS (10K)
3.5" SAS (15K), nearline SAS (7.2K), SATA (7.2K)

Maximum Internal Storage:
8TB–24.6TB* (depending on chassis)

External Storage:
For information about Dell external storage options, visit Dell.com/Storage.
Maximum internal storage:
Up to 32TB
Maximum internal storage:
Up to 10TB

Hot-plug hard drive options:
2.5” PCIe SSD, SAS SSD, SATA SSD, SAS (15K, 10K), nearline SAS (7.2K), SATA (7.2K), SAS 512n (15K)
Self-Encrypting Drives available
Hot-plug Hard Drive Options:
2.5" SATA SSD, SAS (10K, 15K), Near-Line SAS (7.2K), SATA (7.2K)

Maximum Internal Storage:
Up to 6TB

External Storage:
For information about Dell external storage options, visit Dell.com/Storage.

Maximum Internal Storage:
32TB

Hot-plug hard drive options:
2.5” PCIe SSD, SAS SSD, SATA SSD, SAS (15K, 10K), nearline SAS (7.2K), SATA (7.2K), SAS 512n (15K)
3.5” SAS (15K), nearline SAS (7.2K), SATA (7.2K)
Self-Encrypting Drives available

Maximum Internal Storage:
50TB

Hot-plug hard drive options:
2.5” SAS SSD, SATA SSD, SAS (15K, 10K), nearline SAS (7.2K), SATA (7.2K), SAS 512n (15K)
3.5” SAS (15K), nearline SAS (7.2K), SATA (7.2K)
Self-encrypting drives available

Hot-plug Hard Drive Options:
2.5" SATA SSD, SAS (10K, 15K), Near Line SAS (7.2K), SATA (7.2K)

Maximum Internal Storage:
Up to 6TB

External Storage:
For information about Dell external storage options, visit Dell.com/Storage.
Maximum internal storage
16TB
Hot-plug Hard Drive Options:
2.5" SATA SSD, SAS (10K, 15K), Near Line SAS (7.2K), SATA (7.2K)

Solid State Storage Cards:
Fusion-io® 160GB ioDrive PCIe solid state storage card
Fusion-io® 640GB ioDrive Duo PCIe solid state storage card
Fusion-io® 320GB ioDrive Mono PCIe solid state storage card
Fusion-io® 640GB ioDrive Mono PCIe solid state storage card
Fusion-io® 1.28TB ioDrive Mono PCIe solid state storage card

Maximum Internal Storage:
Up to 16TB

External Storage:
For information about Dell external storage options, visit Dell.com/Storage.
24 x 1.2TB HDD or
16 x 1.2TB HDD + 8 x 1.6TB PowerEdge Express Flash NVMe PCIe SSDs

Supported drives

Hot-plug hard drive options:
2.5” SATA/SAS SSD, SAS HDD (15K, 10K), nearline SAS HDD (7.2K)
2.5” PCIe SSDs: Dell PowerEdge NVMe Express Flash PCIe SSD

Slots

1x PCIe 3.0 x16 slot; full height, half length2 PCIe slots:
One x8 PCIe slot with x4 bandwidth, half-length, half-height
One x16 PCIe slot with x16 bandwidth, half-length, full-height
1 PCI slot
Slot 1: PCIe x16
Slot 2: Propriety for SAS 6/iR Modular card only

2 PCIe slots:

With two processors:
One x16 PCIe slot with x16 bandwidth, half-length, half-height
One x16 PCIe slot with x16 bandwidth, half-length, full-height

With one processor:
One x8 PCIe slot with x4 bandwidth, half-length, half-height
One x16 PCIe slot with x16 bandwidth, half-length, full-height

3 PCIe G2 slots + 1 storage slot:

One x8 slot
Two x4 slots
One Storage x4 slot
4 PCIe slots:

With two processors:

One x16 PCIe slot with x16 bandwidth, half-length, half-height
One x16 PCIe slot with x8 bandwidth, full-length, full-height
Two x16 PCIe slots with x8 bandwidth, half-length, full-height

With one processor:

One x8 PCIe slot with x4 bandwidth, half-length, half-height
One x16 PCIe slot with x8 bandwidth, full-length, full-height
Two x8 PCIe slots with x4 bandwidth, half-length, full-height
3 PCIe slots:
Two x16 slots with x16 bandwidth, half-height, half-length
One x16 slot with x8 bandwidth, half-height, half-length
(ten-drive-bay configuration is available only with 3 PCIe slot option)

or

2 PCIe slots:
One x16 slot with x16 bandwidth, full-height, 3/4 length
One x16 slot with x16 bandwidth (or x8 with one processor only), half-height, half-length
6 PCIe G2 slots + 1 storage slot:
Five x8 slots (Three with x16 connectors)
One x4 slot
One x4 Storage slot
7 PCIe slots:
One x16 full-length, full-height
Three x8 full-length, full-height
Three x8 half-length, half-height
6 PCIe slots:
Two x16 full-length, full-height
One x8 full-length, full-height
Three x8 half-length, half-height
6 PCIe G2 slots + 1 Storage slot:
Five x8 slots (Three with x16 connectors)
One x4 slot(with x8 connectors)
One x4 Storage slot(with x8 connectors)
7 PCIe slots:
Two x16 half-length, full-height
One x8 half-length, full-height
Three x8 half-length, half-height
One x8 half-length, full-height for the RAID controller
Up to 10 PCIe G2 slots + 1 storage slot:

Standard:
7 PCIe Gen2 slots:
Two x4 slots
Four x8 slots
One x16 slot

Optional: 10 PCIe Gen2 slots:
Six x4 slots
Four x8 slots
One storage x8 slot
I/O slots:
Up to 10 PCIe slots; 8 PCIe 3.0, + 1 RAID slot, + 1 NDC slot + 2 optional PCIe slots

Drive Controllers

Chipset based SATA, PERC S110 (Embedded SW RAID)

RAID Controllers

(Optional)
RAID:
PERC S110
PERC H310

NON-RAID:
6GB SAS HBA

External Storage:
PERC H810
Internal controllers:
PERC S110 (SW RAID)
PERC H310
PERC H710

External HBAs (RAID):
PERC H810

External HBAs (non-RAID):
6Gbps SAS HBA

 

Internal Controllers:
PERC H200 (6Gb/s)
PERC H700 (6Gb/s); Non-Volatile battery-backed cache: 512MB, 1G
PERC S300 (software based)
SAS 6/iR

External Controllers:
PERC H800 (6Gb/s); Non-Volatile battery-backed cache: 512MB, 1G

External HBAs (non-RAID)
6GB/s SAS HBA
Internal Controllers:
PERC H200 (6Gb/s)
PERC H700 (6Gb/s); Non-Volatile battery-backed cache: 512MB, 1G SAS 6/iR
PERC S300 (software based/ 8 HDD chassis only)

External Controllers:
PERC H800 (6Gb/s); Non-Volatile battery-backed cache: 512MB, 1G SAS 6/iR

External HBAs (non-RAID)
6GB/s SAS HBA
Internal controllers:
PERC S110 (SW RAID)
PERC H310
PERC H710
PERC H710P
External HBAs (RAID):
PERC H810
External HBAs (non-RAID):
6Gbps SAS HBA
Internal Controllers:

PERC
H200PERC
H700

External Controllers:

PERC H800
SAS 5/E with 512MB battery backed cache
PERC 6/E with 512MB battery backed cache
6GBs SAS HBA
LSI2032 PCIe SCSI HBA
Internal controllers:
PERC S110 (SW RAID)
PERC H310
PERC H710
PERC H710P
External HBAs (RAID):
PERC H810
External HBAs (non-RAID):
6Gbps SAS HBA
Internal Controllers:
PERC H200 (6Gb/s)
PERC H700 (6Gb/s) with 512MB battery-backed cache; 512MB, 1G Non-Volatile battery-backed cache
SAS 6/iR
PERC 6/i with 256MB battery-backed cache

External Controllers:
PERC H800 (6Gb/s) with 512MB of battery-backed cache; 512MB, 1G Non-Volatile battery-backed cache
PERC 6/E with 256MB or 512MB of battery-backed cache

External HBAs (non-RAID):
6Gbps SAS HBA
SAS 5/E HBA
LSI2032 PCIe SCSI HBA
Internal controllers:
PERC H310
PERC H710
PERC H710P
External HBAs (RAID):
PERC H810
External HBAs (non-RAID):
6Gbps SAS HBA
Internal Controllers:

PERC H200
PERC H700 (6Gb/s) with 512MB battery-backed cache; 512MB, 1GB Non-Volatile battery-backed cache

External Controllers:

PERC H800 (6Gb/s) with 512MB of battery-backed cache; 512MB, 1GB Non-Volatile battery-backed cache

External HBAs (non-RAID):

6Gbps SAS HBA
SAS 5/E HBA
LSI2032 PCIe SCSI HBA

Network Controller

2x GbE LOM w/o TOE

Embedded NIC:
Broadcom® 5720 Dual Port 1Gb LOM

I/O adapter options:

1Gb Ethernet:
Broadcom 5720 Dual Port 1Gb NIC
Broadcom 5719 Quad Port 1Gb NIC
Intel I350 Dual Port 1Gb stand-up adapter
Intel I350 Quad Port 1Gb stand-up adapter

10Gb Converged Ethernet:
Brocade® BR1020 Dual Port 10Gb CNA
QLogic® QLE8262 Dual Port 10Gb DA/SFP+
Broadcom 57810S Dual Port 10Gb Base-T CNA
Broadcom 57810S Dual Port 10Gb DA/SFP+ CNA

10Gb Ethernet:
Intel X520 Dual Port 10Gb DA/SFP+ server adapter
Intel X540 Dual Port 10Gb Base-T adapter

FC8/FC4 HBA:
QLogic QLE2460 4Gb Single Port FC HBA
QLogic QLE2462 4Gb Dual Port FC HBA
QLogic QLE2560 8Gb Single Port FC HBA
QLogic QLE2562 8Gb Dual Port FC HBA
Emulex® LPe-12000-E 8Gb Single Port FC HBA
Emulex LPe-12002-E 8Gb Dual Port FC HBA
Brocade 815 8Gb Single Port FC HBA
Brocade 825 8Gb Dual Port FC HBA

One Dual-Port Broadcom 5716 Gigabit NIC (total of two 1x GB ports)

Embedded NIC:
Broadcom® 5720 Dual Port 1Gb LOM

I/O adapter options:

1Gb Ethernet:

Broadcom 5720 Dual Port 1Gb NIC
Broadcom 5719 Quad Port 1Gb NIC
Intel I350 Dual Port 1Gb stand-up adapter
Intel I350 Quad Port 1Gb stand-up adapter

10Gb Converged Ethernet:
Brocade® BR1020 Dual Port 10Gb CNA
QLogic® QLE8262 Dual Port 10Gb DA/SFP+
Broadcom 57810S Dual Port 10Gb Base-T CNA
Broadcom 57810S Dual Port 10Gb DA/SFP+ CNA

10Gb Ethernet:
Intel X520 Dual Port 10Gb DA/SFP+ server adapter
Intel X540 Dual Port 10Gb Base-T adapter

FC8/FC4 HBA:
QLogic QLE2460 4Gb Single Port FC HBA
QLogic QLE2462 4Gb Dual Port FC HBA
QLogic QLE2560 8Gb Single Port FC HBA
QLogic QLE2562 8Gb Dual Port FC HBA
Emulex® LPe-12000-E 8Gb Single Port FC HBA
Emulex LPe-12002-E 8Gb Dual Port FC HBA
Brocade 815 8Gb Single Port FC HBA
Brocade 825 8Gb Dual Port FC HBA

One Dual-Port Broadcom 5716 Gigabit NIC (total of two 1x GB ports)Embedded NIC:
Broadcom® 5720 Dual Port 1Gb LOM
I/O adapter options:
1Gb Ethernet:
Broadcom 5720 Dual Port 1Gb NIC
Broadcom 5719 Quad Port 1Gb NIC
Intel I350 Dual Port 1Gb stand-up adapter
Intel I350 Quad Port 1Gb stand-up adapter
10Gb Converged Ethernet:
Brocade® BR1020 Dual Port 10Gb CNA
QLogic® QLE8262 Dual Port 10Gb DA/SFP+
Broadcom 57810S Dual Port 10Gb Base-T CNA
Broadcom 57810S Dual Port 10Gb DA/SFP+ CNA
10Gb Ethernet:
Intel X520 Dual Port 10Gb DA/SFP+ server adapter
Intel X540 Dual Port 10Gb Base-T adapter
FC16/FC8/FC4 HBA:
QLogic QLE2460 4Gb Single Port FC HBA
QLogic QLE2462 4Gb Dual Port FC HBA
QLogic QLE2560 8Gb Single Port FC HBA
QLogic QLE2562 8Gb Dual Port FC HBA
QLogic QLE2660 16Gb Single Port FC HBA
QLogic QLE2662 16Gb Dual Port FC HBA
Emulex® LPe-12000-E 8Gb Single Port FC HBA
Emulex LPe-12002-E 8Gb Dual Port FC HBA
Brocade 815 8Gb Single Port FC HBA
Brocade 825 8Gb Dual Port FC HBA
Two Dual-Port Broadcom 5709C Gigabit NICs (Total of 4x 1GbE ports)Two Dual-Port Broadcom 5709C Gigabit NICs1GbE or 10Gb embedded NIC options with iSCSI offload
4-port (4 x 1GbE) Embedded NIC Broadcom 5709c
4-port (2 x 10Gb + 2 x 1GbE) Embedded NIC Broadcom 57711 + Broadcom 5709c

Power

Non-redundant, 250W (80+ Silver); auto-ranging (100V~240V)

Platinum efficiency, hot-plug, redundant 350W power supply
Bronze efficiency, cabled 350W power supply
Auto-ranging power supplies

Non-Redundant, 480W (80+ BRONZE)
Optional Redundant, 500W (80+ SILVER)
Platinum efficiency 550W and 350W power supplies
Silver efficiency cabled 550W power supply
Auto-ranging power supplies
Redundant 750W hot-plug power suppliesTitanium efficiency, hot-plug redundant 750W power supply
Platinum efficiency, hot-plug redundant 750W or 495W power supply
Silver efficiency, cabled 550W power supply
91% efficiency, 1100W DC power supply
Auto-ranging power supplies
Titanium efficiency, hot-plug redundant 750W power supply
Platinum efficiency, hot-plug redundant 495W, 750W or 1100W power supplies
Auto-ranging power supplies
  • One hot-pluggable non-redundant 750W power supply
  • One hot-pluggable non-redundant 1100W power supply
  • Two hot-pluggable redundant 750W power supplies
  • Two hot-pluggable redundant 1100W power supplies
Titanium efficiency, hot-plug redundant 750W power supply
Platinum efficiency, hot-plug redundant 495W, 750W or 1100W power supplies
Auto-ranging power supplies
Platinum efficiency 495W, 750W or Platinum+ efficiency 1100W power supplies
Auto-ranging power supplies
One hot-pluggable non-redundant 1100W power supply
Two hot-pluggable redundant 1100W power supplies
Titanium efficiency, hot-plug redundant 750W power supply
Platinum efficiency, hot-plug redundant 750W or 1100W power supplies
Auto-ranging power supplies
Internal Controllers:
PERC H700 (6Gb/s) with 512MB battery-backed cache; 512MB, 1G Non-Volatile battery-backed cache
PERC H200 (6Gb/s)

External Controllers:
PERC H800 (6Gb/s) with 512MB of battery-backed cache; 512MB, 1G Non-Volatile battery-backed cache
SAS 5/E
PERC 6/E6Gbps SAS

External HBAs (non-RAID):
6Gbps SAS HBA
SAS 5/E HBA
LSI2032 PCIe SCSI HBA

Power Supply

Hot plug redundant PSUs
4 x 750W (Energy Smart PSU )(or) 4 x 1100W (High Output PSU)
Hot-plug redundant PSUs: 750W AC, 1100W AC and DC

Chassis

1U rackForm factor
1U rack
1.69 H x 17.09 W x 24.69 D (in)
43.0 H x 434.0 W x 627.1 D (mm- w/o ear, w/o bezel)

Rack Support

ReadyRails™ sliding rails with optional cable management arm for 4-post racks (optional adapter brackets required for threaded hole racks)
ReadyRails™ static rails for 2-post and 4-post racks
Form factor:
1U rack
8 HDD Chassis
3.40 H x 17.19 W x 24.09 D (in)
86.4 H x 436.6 W x 610.2 D (mm)

12 HDD Chassis
3.42 H x 17.53 W x 26.17 D (in)
86.7 H x 445.2 W x 664.6 D (mm)

Rack Support

ReadyRails™ sliding rails with optional cable management arm for 4-post racks (optional adapter brackets required for threaded hole racks)
ReadyRails™ static rails for 2-post and 4-post racks
Form factor:
2U rack
Rack Chassis

3.40 H x 18.99 W x 28.25 D (in)
8.64 H x 48.24 W x 71.75 D (cm)

Rack Support

Sliding ReadyRails™ for 4-post racks and optional support for cable management arm
Rack Chassis
3.40" H x 18.99" W x 28.25" D
9 cm H x 48 cm W x 72 cm D

Rack Support

Sliding ReadyRails™ for 4-post racks, static ReadyRails™ for 4-post and 2-post racks, and optional support for cable management arm
17 cm (6.80") H x 42 cm (16.60") W x 79 cm (31.02") D
172.6 H x 482 W x 753 D (mm)

Rack Support

Sliding ReadyRails™ for 4-post racks, static Ready Rails™ for 4-post and 2-post racks, and optional support for cable management arm
1U/2U Rail Attachment Brackets
Rack support:
ReadyRails II, the sliding rail system for the R920, provides tool-less support for 4-post racks with square or unthreaded round mounting holes, including all generations of Dell racks. The sliding rail system also supports tooled mounting in 4-post threaded racks.

Dimensions:
H: 6.8” (172.6mm)
W: 18.99” (482.4mm)
D: 31.59” (802.3mm) with psu and bezel
D: 29.65” (753mm) without bezel

Management

Remote management
iDRAC7 Enterprise with Lifecycle Controller (optional)

Systems management
Basic management
IPMI 2.0 compliant
Dell OpenManage Essentials
Dell OpenManage Mobile
Dell OpenManage Power Center
Dell OpenManage Integrations:
Dell OpenManage Integration Suite for Microsoft System Center
Dell OpenManage Integration for
VMware® vCenter
Dell OpenManage

Connections:
HP Operations Manager, IBM Tivoli® Netcool®, and CA Network and Systems Management
Dell OpenManage Plug-in for Oracle Database Manager
Remote management

Basic management (default)
iDRAC7 with Lifecycle Controller
iDRAC7 Express (upgrade option), iDRAC7 Enterprise (upgrade option) 8GB or 16GB vFlash media (upgrade options)

Systems management

IPMI 2.0 compliant
Dell OpenManage™ Essentials and Dell Management Console
Dell OpenManage Power Center

Dell OpenManage Connections:
OpenManage Integration Suite for Microsoft® System Center
Dell plug-in for VMware® vCenter™
HP Operations Manager, IBM Tivoli® Netcool®, and CA Network and Systems Management
Dell™ OpenManage™
BMC, IPMI 2.0 compliant
Lifecycle Controller enabled via optional: iDRAC6 Express, or iDRAC6 Enterprise and vFlash
Unified Server Configurator
Remote management:
Basic management (default)
iDRAC7 with Lifecycle Controller
iDRAC7 Express (upgrade), iDRAC7 Enterprise (upgrade) 8GB vFlash media (upgrade), 16GB vFlash media (upgrade)

Systems management:
IPMI 2.0 compliant
Dell OpenManage™ Essentials and Dell Management Console
Dell OpenManage Power Center
Dell OpenManage Connections:
OpenManage Integration Suite for Microsoft® System Center
Dell plug-in for VMware® vCenter™
HP Operations Manager, IBM Tivoli® Netcool®, and CA Network and Systems Management
Dell™ OpenManage™
BMC, IPMI 2.0 compliant
Lifecycle Controller enabled via optional: iDRAC6 Express, or iDRAC6 Enterprise and vFlash
Unified Server Configurator

Remote Management
Basic management (default)
iDRAC7 with Lifecycle Controller
iDRAC7 Express (upgrade), iDRAC7 Enterprise (upgrade)
8GB vFlash (upgrade), 16GB vFlash (upgrade)

Systems Management
IPMI 2.0 compliant
OpenManage™ Essentials
OpenManage Power Center
Dell OpenManage Connections:
• OpenManage Integration Suite for Microsoft® System Center
• Dell plug-in for VMware® vCenter®
• HP Operations Manager, IBM Tivoli® Netcool®, and CA Network and Systems Management (NSM)

Remote Management
iDRAC7 with Lifecycle Controller
iDRAC7 Express (default), iDRAC7 Enterprise (upgrade option),
8GB vFlash media (upgrade option), 16GB vFlash media (upgrade option)

Systems Management
IPMI 2.0 compliant
Dell OpenManage™ Essentials
Dell OpenManage Power Center
Dell OpenManage Connections:
• Dell OpenManage Integration Suite for Microsoft® System Center
• Dell plug-in for VMware® vCenter™
HP Operations Manager, IBM Tivoli® Netcool® , and CA Network and Systems Management
Dell™ OpenManage™
BMC, IPMI 2.0 compliant
iDRAC6 Express, with optional upgrade to iDRAC6 Enterprise and vFlash
Remote Management:
iDRAC7 with Lifecycle Controller
iDRAC7 Express (default), iDRAC7 Enterprise (upgrade option)
8GB vFlash media (upgrade option), 16GB vFlash media (upgrade optional)

Systems Management:
IPMI 2.0 compliant
Dell OpenManage™ Essentials
Dell OpenManage Power Center
Dell OpenManage Connections:
• Dell OpenManage Integration Suite for Microsoft® System Center
• Dell plug-in for VMware® vCenter™
• HP Operations Manager, IBM Tivoli® Netcool®, and CA Network and Systems Management
Remote Management:
iDRAC7 with Lifecycle Controller
iDRAC7 Express (default), iDRAC7 Enterprise (upgrade option)
8GB vFlash media (upgrade option), 16GB vFlash media (upgrade optional)

Systems Management:
IPMI 2.0 compliant
OpenManage™ Essentials
OpenManage Power Center
OpenManage Connections:
• Dell OpenManage Integration Suite for Microsoft® System Center
• Dell plug-in for VMware® vCenter™
• HP Operations Manager, IBM Tivoli® Netcool®, and CA Network and Systems Management
Dell™ OpenManage™
BMC, IPMI 2.0 compliant
iDRAC6 Express, with optional upgrade to iDRAC6 Enterprise and vFlash
Microsoft® System Center Essential (SCE) 2010 v2
Remote management:
iDRAC7 Express (default) or iDRAC7 Enterprise (upgrade option), both with Lifecycle Controller
8GB or 16GB vFlash media (upgrade options)

Systems management:
IPMI 2.0 compliant
Dell OpenManage™ Essentials
Dell OpenManage Power Center
Dell OpenManage Connections:
• Dell OpenManage Integration Suite for Microsoft® System Center
• Dell plug-in for VMware® vCenter™
• HP Operations Manager, IBM Tivoli® Netcool®, and CA Network and Systems Management
Dell™ OpenManage™
BMC, IPMI 2.0 compliant, iDRAC6 Express
Unified Server Configurator
Lifecycle controller enabled via optional: iDRAC6 Express, iDRAC6 Enterprise and vFlash
Microsoft® System Center Essential (SCE) 2010 v2
Remote management:
iDRAC7 with Lifecycle Controller
iDRAC7 Express (default)
iDRAC7 Enterprise (upgrade option)
8GB or 16GB vFlash media (upgrade options)

Systems management:
IPMI 2.0 compliant
Dell OpenManage Essentials
Dell OpenManage Mobile
Dell OpenManage Power Center
Dell OpenManage Integrations:
Dell OpenManage Integration Suite for Microsoft System Center
Dell OpenManage Integration for VMware® vCenter
Dell OpenManage Connections:
HP Operations Manager, IBM Tivoli® Netcool®, and CA Network and Systems Management
Dell OpenManage Plug-in for Oracle Database Manager

Video Support

Matrox G200eW w/ 8MB memory integrated in Nuvoton WPCM450 (BMC controller) and supports 2D graphics only.

Rack Support

ReadyRails™ static rails for tool-less mounting in 4-post racks with square or unthreaded round holes or tooled mounting in 4-post threaded hole racks, with support for tooled mounting in 2-post racks.ReadyRails™ II sliding rails for tool-less mounting in 4-post racks with square or unthreaded round holes or tooled mounting in 4-post threaded hole racks, with support for optional tool-less cable management arm

ReadyRails static rails for tool-less mounting in 4-post racks with square or unthreaded round holes or tooled mounting in 4-post threaded and 2-post (Telco) racks
ReadyRails™ II sliding rails for tool-less mounting in 4-post racks with square or unthreaded round holes or tooled mounting in 4-post threaded hole racks, with support for optional tool-less cable management arm

ReadyRails static rails for tool-less mounting in 4-post racks with square or unthreaded round holes or tooled mounting in 4-post threaded and 2-post (Telco) racks
ReadyRails™ II sliding rails for tool-less mounting in 4-post racks with square or unthreaded round holes or tooled mounting in 4-post threaded hole racks, with support for optional tool-less cable management arm

ReadyRails static rails for tool-less mounting in 4-post racks with square or unthreaded round holes or tooled mounting in 4-post threaded and 2-post (Telco) racks
ReadyRails II sliding rails for tool-less mounting in 4-post racks with square or unthreaded round holes or tooled mounting in 4-post threaded hole racks, with support for optional tool-less cable management arm
ReadyRails static rails for tool-less mounting in 4-post racks with square or unthreaded round holes or tooled mounting in 4-post threaded and 2-post (Telco) racks
ReadyRails II sliding rails for tool-less mounting in 4-post racks with square or unthreaded round holes or tooled mounting in 4-post threaded hole racks, with support for optional tool-less cable management arm
ReadyRails static rails for tool-less mounting in 4-post racks with square or unthreaded round holes or tooled mounting in 4-post threaded and 2-post (Telco) racks
ReadyRails II sliding rails for tool-less mounting in 4-post racks with square or unthreaded round holes or tooled mounting in 4-post threaded hole racks, with support for optional tool-less cable management arm
ReadyRails static rails for tool-less mounting in 4-post racks with square or unthreaded round holes or tooled mounting in 4-post threaded and 2-post (Telco) racks
ReadyRails II sliding rails for tool-less mounting in 4-post racks with square or unthreaded round holes or tooled mounting in 4-post threaded hole racks, with support for optional tool-less cable management arm
ReadyRails static rails for tool-less mounting in 4-post racks with square or unthreaded round holes or tooled mounting in 4-post threaded and 2-post (Telco) racks

Dimensions

H: 1.66” (42.4 mm) (without ear/bezel)
W: 17.09” (434 mm) (without ear/bezel)
D: 15.52” (394.3 mm) (without ear/bezel)

Regulatory

Product Safety, EMC and Environmental Datasheets
Dell Regulatory Compliance Home Page
Dell and the Environment
Product Safety, EMC and Environmental Datasheets
Dell Regulatory Compliance Home Page
Dell and the Environment

ENERGY STAR®
The Dell PowerEdge R320 has earned the ENERGY STAR® Enterprise Server designation.
ENERGY STAR and the ENERGY STAR mark are registered U.S. marks.
ENERGY STAR
Dell and the Environment
Dell Regulatory Compliance Home Page
Product Safety, EMC and Environmental Datasheets
Dell Regulatory Compliance Home Page
Dell and the Environment

ENERGY STAR®
The Dell PowerEdge R420 has earned the ENERGY STAR® Enterprise Server designation.
ENERGY STAR and the ENERGY STAR mark are registered U.S. marks.
ENERGY STAR
Product Safety, EMC and Environmental Datasheets
Dell Regulatory Compliance Home Page
Dell and the Environment

ENERGY STAR®
The Dell PowerEdge R515 has earned the ENERGY STAR® Enterprise Server designation.
ENERGY STAR and the ENERGY STAR mark are registered U.S. marks.
ENERGY STAR
Product Safety, EMC and Environmental Datasheets
Dell Regulatory Compliance Home Page
Dell and the Environment

ENERGY STAR®
The Dell PowerEdge R520 has earned the ENERGY STAR® Enterprise Server designation.
ENERGY STAR and the ENERGY STAR mark are registered U.S. marks.
ENERGY STAR
Product Safety, EMC and Environmental Datasheets
Dell Regulatory Compliance Home Page
Dell and the Environment

ENERGY STAR®
The Dell PowerEdge R620 has earned the ENERGY STAR® Enterprise Server designation.
ENERGY STAR and the ENERGY STAR mark are registered U.S. marks.
ENERGY STAR
REGULATORY MODEL: E05S
REGULATORY TYPE: E05S003
Product Safety, EMC and Environmental Datasheets
Dell Regulatory Compliance Home Page
Dell and the Environment

ENERGY STAR®
The Dell PowerEdge R715 has earned the ENERGY STAR® Enterprise Server designation.
ENERGY STAR and the ENERGY STAR mark are registered U.S. marks.
ENERGY STAR
Product Safety, EMC and Environmental Datasheets
Dell Regulatory Compliance Home Page
Dell and the Environment

ENERGY STAR®
The Dell PowerEdge R720 has earned the ENERGY STAR® Enterprise Server designation.
ENERGY STAR and the ENERGY STAR mark are registered U.S. marks.
ENERGY STAR
Product Safety, EMC and Environmental Datasheets
Dell Regulatory Compliance Home Page
Dell and the Environment

ENERGY STAR®
The Dell PowerEdge R720xd has earned the ENERGY STAR® Enterprise Server designation.
ENERGY STAR and the ENERGY STAR mark are registered U.S. marks.
ENERGY STAR
Regulatory Model: E05S
Regulatory Type: E05S002
Product Safety, EMC and Environmental Datasheets
Dell Regulatory Compliance Home Page
Dell and the Environment
Product Safety, EMC and Environmental Datasheets
Dell Regulatory Compliance Home Page
Dell and the Environment

ENERGY STAR®
The Dell PowerEdge R820 has earned the ENERGY STAR® Enterprise Server designation.
ENERGY STAR and the ENERGY STAR mark are registered U.S. marks.
ENERGY STAR
Regulatory Model: E06S
Regulatory Type: E06S001
Product Safety, EMC and Environmental Datasheets
Dell Regulatory Compliance Home Page
Dell and the Environment
Product Safety, EMC and Environmental Datasheets
Dell Regulatory Compliance Home Page
Dell and the Environment

Drive Bays

Up to eight 2.5” hot-plug SAS, SATA or SSD
Up to four 3.5" hot-plug SAS, SATA or SSD
4 hard drive chassis: 2.5” or 3.5” SAS, SATA or SSD drivesUp to eight 2.5” hot-plug SSD, SAS, or SATA or up to four 3.5” hot-plug SAS, SATA, or SSDHot-Swap options available:

Up to eight or twelve 3.5” SAS or SATA, or 2.5” SAS or SSD drives
Up to eight 3.5” hot-plug SAS, SATA or SSDUp to ten 2.5" hot-plug SAS, SATA, or SSD or up to four hot-plug 2.5" SAS, SATA, or SSD + two PCIe SSD6 hard drive chassis: 6 cm (2.5") SAS, SATA or SSD drivesUp to eight 3.5" drives or up to sixteen 2.5" drivesUp to twenty-six 2.5” drives or up to twelve 3.5” drives plus two 2.5” drivesHot-Swap options available:

Up to six 2.5” SATA SSD, SAS, nearline SAS, or SATA drives
Up to sixteen 2.5” hot-plug SAS, SATA, or SSD

Hard drives:
Hot-plug hard drive options:
2.5” PCIe SSD, SAS SSD, SATA SSD, SAS (15K, 10K), nearline SAS (7.2K), SATA (7.2K), SAS 512e (15K)
Self-Encrypting drives available
Hot-Swap options available:

Up to sixteen 2.5” SATA SSD, SAS, nearline SAS, or SATA drives
Up to 24 2.5” hot-plug 12Gb/6Gb SAS HDD or SAS/SATA SSD
Up to 8 front-accessible Express Flash NVMe PCIe SSD (PCIe 3.0)

RAID Controllers:

Internal controllers:
PERC H730P

External controllers:
PERC H8106Gbps SAS HBA

Availability

High-efficiency, hot-plug, redundant power supplies; hot-plug hard drives; TPM; dual internal SD support; fan fault tolerance; optional bezel; luggage tag; ECC memory, interactive LCD screen; ENERGY STAR® compliantHot-plug hard drives, Hot-plug redundant power, ECC memory, and Quad-pack LED diagnostic or interactive LCD only with hot-swap HDD chassisHigh-efficiency, hot-plug, redundant power supplies; hot-plug hard drives; TPM; dual internal SD support; fan fault tolerance; optional bezel; luggage tag; ECC memory, interactive LCD screen; ENERGY STAR® compliantHot-plug hard drives, Hot-plug redundant power, ECC memory, and Quad-pack LED diagnostic (12HDD chassis) or interactive LCD (8HDD chassis)High-efficiency, hot-plug, redundant power supplies; DC power supply; hot-plug hard drives; TPM; dual internal SD support; fan fault tolerance; optional bezel; luggage tag; ECC memory, interactive LCD screen; ENERGY STAR® compliant; extended power range; switch independent partitioningHigh-efficiency, hot-plug, redundant power supplies; DC power supplies; hot-plug hard drives; TPM; dual internal SD support; hot-plug redundant fans; optional bezel; luggage-tag; ECC memory; interactive LCD screen; extended thermal support; ENERGY STAR® compliant; extended power range; Switch Agnostic Partitioning (SWAP)Hot-pluggable hard drives, Hot-pluggable redundant power supply, internal dual SD module, ECC memory, interactive LCD screenHigh-efficiency, hot-plug, redundant power supplies; hot-plug drive bays; TPM; dual internal SD support; hot-plug
redundant fan; optional bezel; luggage-tag; ECC memory, interactive LCD screen; extended thermal support; ENERGY STAR® compliant, extended power range; switch agnostic partitioning (SWAP)
High-efficiency PSU; hot-plug redundant PSU; hot-plug drive bays; TPM/No-TPM; dual internal SD support; hot-plug redundant fan; optional bezel; luggage-tag; ECC memory, extended thermal support; ENERGY STAR® compliant, extended power range; Switch Agnostic Partitioning (SWAP)
Hot-plug hard drives, Hot-plug redundant power, dual SD modules, ECC memory, and an interactive LCD screenHigh-efficiency, hot-plug, redundant power supplies; hot-plug drive bays; TPM; dual internal SD support; hot-plug
redundant fans; optional bezel; luggage-tag; ECC memory, interactive LCD screen; extended thermal support;
ENERGY STAR® compliant, extended power range; Switch Agnostic Partitioning (SWAP)
Hot-plug hard drives, Hot-plug redundant power, Hot plug redundant fans, ECC memory, Internal dual SD Module, redundant coolingHot-plug hard drives, hot-plug redundant power, hot-plug redundant fans, ECC memory, internal dual SD module

Communications

Intel® 10GBase-T Copper Single Port NIC, PCI-E x8
Intel PRO 1000 PT Single Port Adapter, Gigabit Ethernet NIC, PCI-E x1
Intel® Gigabit ET Dual Port Server Adapter, PCI-E x4
Intel® Gigabit ET Quad Port Server Adapter, PCI-E x4
Intel® Ethernet X520 DA2 Dual-Port 10 Gigabit Server Adapter
Intel® X520-T2 Dual-Port 10 Gigabit Ethernet Server Adapter
Broadcom® BCM5709C IPV6 Gigabit Copper Dual Port NIC with TOE and iSCSI Offload, PCI-E x4
Broadcom® BCM5709C IPV6 Gigabit Copper Dual Port NIC with TOE, PCI-E x4
Broadcom® BCM5709C 10/100/1000BASET Quad Port NIC
Broadcom® NetXtreme™ II 57711 Dual-Port SFP+/Direct Attach 10Gb Ethernet PCI-Express Network Interface Card with TOE and iSCSI Offload

Optional add-in CNA or FC HBAs:
BR1020 10G Converged Network Adapter (CNA) – dual port
Emulex LPe11002 FC4 HBA, Dual Port
Emulex LPe1150 FC4 HBA, Single Port
Emulex LPe12000 8Gbps FC HBA, Single Port
Emulex LPe12002 8Gbps FC HBA, Dual Port
Emulex OCE10102FXD, 10G PCI-e FCoE CNA, Dual Port
Qlogic QLE220 FC4 HBA, Single Port
Qlogic QLE2460 FC4 HBA, Single Port
Qlogic QLE2462 FC4 HBA, Dual Port
Qlogic QLE2560 8Gbps FC HBA, Single Port
Qlogic QLE2562 8Gbps FC HBA, Dual Port
Qlogic QLE8152 8Gbps FC HBA, Dual Port
Brocade FC HBA BR815
Brocade FC HBA BR825
Intel® 10GBase-T Copper Single Port NIC, PCI-E x8
Intel PRO 1000 PT Single Port Adapter, Gigabit Ethernet NIC, PCI-E x1
Intel® Gigabit ET Dual Port Server Adapter, PCI-E x4
Intel® Gigabit ET Quad Port Server Adapter, PCI-E x4
Intel Ethernet X520 DA2 Dual-Port 10 Gigabit Server Adapter
Intel® X520-T2 Dual-Port 10 Gigabit Ethernet Server Adapter 
Broadcom® BCM5709C IPV6 Gigabit Copper Dual Port NIC with TOE and iSCSI Offload, PCI-E x4
Broadcom® BCM5709C IPV6 Gigabit Copper Dual Port NIC with TOE, PCI-E x4
Broadcom® BCM5709C 10/100/1000BASET Quad Port NIC
Broadcom® NetXtreme™ II 57711 Dual-Port SFP+/Direct Attach 10Gb Ethernet PCI-Express Network Interface Card with TOE and iSCSI Offload 

Optional add-in CNA or FC HBAs:

BR1020 10G Converged Network Adapter (CNA) – dual port
Emulex LPe11002 FC4 HBA, Dual Port
Emulex LPe1150 FC4 HBA, Single Port
Emulex LPe12000 8Gbps FC HBA, Single Port
Emulex LPe12002 8Gbps FC HBA, Dual Port
Emulex OCE10102FXD, 10G PCI-e FCoE CNA, Dual Port
Qlogic QLE220 FC4 HBA, Single Port
Qlogic QLE2460 FC4 HBA, Single Port
Qlogic QLE2462 FC4 HBA, Dual Port
Qlogic QLE2560 8Gbps FC HBA, Single Port
Qlogic QLE2562 8Gbps FC HBA, Dual Port
Qlogic QLE8152 8Gbps FC HBA, Dual Port
Brocade FC HBA BR815
Brocade FC HBA BR825
Broadcom® 5720 quad-port 1GbE Base-T (no TOE or iSCSI offload)
Intel I350 quad-port 1GbE Base-T (no TOE or iSCSI offload)
Intel X540 dual-port 10GbE Base-T with 2 x 1GbE (FCoE capability enabled on the 10GbE ports)
Broadcom 57800S dual-port 10GbE Base-T with 2 x 1GbE (TOE and iSCSI offload available on 10GbE ports) Broadcom 57800S dual-port 10GbE SFP+ with 2 x 1GbE (TOE and iSCSI offload available on 10GbE ports)Broadcom 57840S quad-port 10GbE SFP+ Rack NDC (NPAR1.0, SRIOV, DCB, iSCSI and FCoE offloads and CEM)
Optional NICs:
Broadcom® BMC57710 10Base-T Copper Single-Port NIC, PCIe x8
Broadcom 5709 IPV6 Dual-Port Gigabit Ethernet NIC, Copper, with TOE PCIe x4
Broadcom 5709 IPV6 Dual-Port Gigabit Ethernet NIC, Copper, TOE/iSCSI PCIe x4
Broadcom NetXtreme® II 57711 Dual Port 10Gb Ethernet SFP+
Broadcom NetXtreme II 5709 Gigabit Copper Quad-Port NIC with TOE and iSCSI offload, PCIe x4
Intel® 10GBase-T Copper Single-Port NIC, PCIe x8
Intel 10GB, Dual-Port SFP+, PCIe x8 NIC
Intel Gigabit ET Dual-Port Server Adapter
Intel Gigabit ET Quad-Port Server Adapter
Brocade CNA BR1020

Optional add-in Fibre Channel HBAs and CNA:
QLogic® QLE2462 FC4 Dual-Port HBA
QLogic QLE220 FC4 Single-Port HBA
QLogic QLE2460 FC4 Single-Port HBA
QLogic QLE2562 FC8 Dual-Port HBA, PCIe 2.0 x4
QLogic QLE2560 FC8 Single-Port HBA, PCIe 2.0 x4
QLogic QLE2660 FC16 Single-Port HBA, PCIe 3.0 x4
QLogic QLE2662 FC16 Dual-Port HBA, PCIe 3.0 x4
QLogic QLE8152 Dual-Port 10 Gbps FCoE CNA
Emulex® LPe-1150 FC4 Single-Port HBA, PCIe 2.0 x4
Emulex LPe-11002 FC4 Dual-Port HBA, PCIe 2.0 x4
Emulex LPe-12000 FC8 Single-Port HBA, PCIe 2.0 x4
Emulex LPe-12002 FC8 Dual-Port HBA, PCIe 2.0 x4
Broadcom® 5720 quad-port 1GbE Base-T (no TOE or iSCSI offload)
Intel I350 quad-port 1GbE Base-T (no TOE or iSCSI offload)
Intel X540 dual-port 10GbE Base-T with 2 x 1GbE (FCoE capability enabled on the 10GbE ports)
Broadcom 57800S dual-port 10GbE Base-T with 2 x 1GbE (TOE and iSCSI offload available on 10GbE ports)
Broadcom 57800S dual-port 10GbE SFP+ with 2 x 1GbE (TOE and iSCSI offload available on 10GbE ports)
Broadcom 57840S quad-port 10GbE SFP+ Rack NDC (NPAR1.0, SRIOV, DCB, iSCSI and FCoE offloads and CEM)
Broadcom® 5720 quad-port 1GbE Base-T (no TOE or iSCSI offload)
Intel I350 quad-port 1GbE Base-T (no TOE or iSCSI offload)
Intel X540 dual-port 10GbE Base-T with 2 x 1GbE (FCoE capability enabled on the 10GbE ports)
Broadcom 57800S dual-port 10GbE Base-T with 2 x 1GbE (TOE and iSCSI offload available on 10GbE ports)
Broadcom 57800S dual-port 10GbE SFP+ with 2 x 1GbE (TOE and iSCSI offload available on 10GbE ports)
Broadcom 57840S quad-port 10GbE SFP+ Rack NDC (NPAR1.0, SRIOV, DCB, iSCSI and FCoE offloads and CEM)
Intel® 10GBase-T Copper Single Port NIC, PCI-E x8
Intel® Single Port Server Adapter, 10Gigabit, SR Optical, PCI-E x8
Broadcom® BMC57710 10Base-T Copper Single Port NIC, PCI-E x8
Intel® Gigabit ET Dual Port Server Adapter
Intel® Gigabit ET Quad Port Server Adapter
Broadcom® NetXtreme™ II 57711 Dual Port 10Gb Eth SFP+
Brocade CNA Dual port adapter
Emulex® CNA iSCSI HBA stand up adapter OCE10102-IX-D
Emulex® CNA iSCSI HBA stand up adapter OCE10102-FX-D
Broadcom® BMC57710 10Base-T Copper Single Port NIC, PCI-E x8

Optional add in HBAs:
Qlogic® QLE 2462 FC4 Dual Port 4 Gbps Fiber Channel HBA
Qlogic® QLE 220 FC4 Single Port 4 Gbps Fiber Channel HBA
Qlogic® QLE 2460 FC4 Single Port 4 Gbps Fiber Channel HBA
Qlogic® QLE2562 FC8 Dual-channel HBA, PCI-E Gen 2 x4
Qlogic® QLE2560 FC8 Single-channel HBA, PCI-E Gen 2 x4
Emulex® LPe-1150 FC4 Single Port 4 Gbps Fiber Channel HBA, PCI-E x4
Emulex® LPe-11002 FC4 Dual Port 4 Gbps Fiber Channel HBA, PCI-E x4
Emulex® LPe-12000, FC8 Single Port 4 Gbps Fiber Channel HBA, PCI-E Gen 2 x4
Emulex® LPe-12002, FC8 Dual Port 4 Gbps Fiber Channel HBA, PCI-E Gen 2 x4
Brocade FC4 and 8 GB HBAs
Broadcom® 5720 quad-port 1GbE Base-T (no TOE or iSCSI offload)
Intel I350 quad-port 1GbE Base-T (no TOE or iSCSI offload)
Intel X540 dual-port 10GbE Base-T with 2 x 1GbE (FCoE capability enabled on the 10GbE ports)
Broadcom 57800S dual-port 10GbE Base-T with 2 x 1GbE (TOE and iSCSI offload available on 10GbE ports)
Broadcom 57800S dual-port 10GbE SFP+ with 2 x 1GbE (TOE and iSCSI offload available on 10GbE ports)
Broadcom 57840S quad-port 10GbE SFP+ Rack NDC (NPAR1.0, SRIOV, DCB, iSCSI and FCoE offloads and CEM)
Embedded NICs:
1GbE or 10Gb embedded NIC options with iSCSI offload
Broadcom® 5709c 4-port (4 x 1GbE) Embedded NIC or
Broadcom 57711 4-port (2 x 10GbE + 2 x 1GbE) Embedded NIC + Broadcom 5709c
Optional NICs:
Broadcom 57710 Single Port 10GbE NIC, Copper CAT6 PCIe-8
Intel DA 10GbE NIC, Dual Port, Optical, PCIe-8
Intel 10GbE Single Port 10GbE NIC, Copper, PCIe-8
Broadcom NetXtreme® II 5709 Gigabit NIC with TOE & iSOE, Quad Port, Copper, PCIe-4, (low profile option)
Broadcom 5709 Dual Port 1GbE NIC with TOE PCIe-4, (low profile option)
Broadcom 5709 Dual Port 1GbE NIC with TOE iSCSI, PCIe-4, (low profile option)
Broadcom NetXtreme® II 57711 10GbE NIC with TOE & iSOE, Dual Port, SFP+, PCIe-8
Intel Gigabit ET NIC, Dual Port, Copper, PCIe-4, (low profile option)
Intel Gigabit ET NIC, Quad Port, Copper, PCIe-4, (low profile option)
Brocade® CNA Dual Port adapter
Emulex® CNA iSCSI HBA stand up adapter OCE10102-IX-D
Emulex CNA iSCSI HBA stand up adapter OCE10102-FX-D
Brocade CNA BR1020
QLogic QLE2660 FC16 Single Port, PCIe 3.0 x4
QLogic QLE2662 FC16 Dual Port, PCIe 3.0 x4
Embedded NICs:
Broadcom® 5720 QP 1Gb Network Daughter Card
Broadcom 57800 2x10Gb DA/SFP+ + 2x1Gb BT Network Daughter Card
Broadcom 57800 2x10Gb BT + 2x1Gb BT Network Daughter Card
Broadcom 57840S Quad Port 10Gb SFP+ Direct Attach Rack Network Daughter Card
Intel Ethernet I350 QP 1Gb Network Daughter Card
Intel X520 DP 10Gb DA/SFP+, + I350 DP 1Gb Ethernet, Network Daughter Card
Intel Ethernet X540 10Gb BT DP + I350 1Gb BT DP Network Daughter Card

Video Card

Matrox G200eW w/ 8MBMatrox G200eW w/ 8MBMatrox G200eW w/ 8MBMatrox G200eW w/ 8MBMatrox® G200eW w/ 8MBMatrox® G200 with 8MB memory

RAID

Internal controllers:
PERC S110 (SW RAID)
PERC H310
PERC H710
PERC H710P

External HBAs (RAID):
PERC H810

External HBAs (non RAID):
6Gbps SAS HBA
Internal controllers:
PERC S110 (SW RAID)
PERC H310
PERC H710
PERC H710P

External HBAs (RAID):
PERC H810

External HBAs (non-RAID):
6Gbps SAS HBA
Internal controllers:
PERC H310
PERC H710
PERC H710P

External HBAs (RAID):
PERC H810

Embedded Hypervisor (Optional)

VMware vSphere ESX and ESXi
close
 
 
CS01