Preview Mode is on. Click here to exit and refresh page.

Intel® Xeon® Scalable Processors

Compare

Dell EMC SCv3000 Series Storage Arrays

View Details
Add to Compare
Add to Compare
Add to Compare
Add to Compare
Storage consolidation for virtualized environments  
Storage consolidation for virtualized environments  
Storage consolidation for virtualized environments  
Storage consolidation for virtualized environments  

Smart Value Flexi | SCv3020 SAS Smart Value Flexi | SCv3020 SAS

Smart Value Flexi | SCv3020iSCSI

Smart Value Flexi | SCv3020FC

Smart Value Flexi | SCv3000 SAS

£11,465.00  £6,477.72 1

£11,144.00  £4,496.36

£11,951.00  £6,752.31

£10,901.00  £6,159.06

...  Show More

i

Affordable storage array with auto-tiering and enterprise-class storage features

Affordable storage array with auto-tiering and enterprise-class storage features

Affordable storage array with auto-tiering and enterprise-class storage features

Affordable storage array with auto-tiering and enterprise-class storage features

Original Price £11,465.00 1

Total Savings Total Savings £4,987.28 ( 44% off ); 1

Shipping Free Free
Dell Price £6,477.72 1

Original Price £11,144.00

Total Savings £6,647.64 ( 60% off );

Shipping Free
Dell Price £4,496.36

Original Price £11,951.00

Total Savings £5,198.69 ( 44% off );

Shipping Free
Dell Price £6,752.31

Original Price £10,901.00

Total Savings £4,741.94 ( 44% off );

Shipping Free
Dell Price £6,159.06
Click to Chat now   ResponsiveLabelsKey_Not_Found(shop_installment_stack_primary_label)  month
 |  ResponsiveLinksKey_Not_Found(shop_installment_stack_secondary_link)
Click to Chat now

ResponsiveLabelsKey_Not_Found(shop_installment_stack_primary_label) 

| 

Finance for just /month¹

Subject to approval from Dell Financial Services²

Financing

ResponsiveLabelsKey_Not_Found(shop_installment_stack_primary_label) month

Click to Chat now

Finance for just £139.84/month¹

Subject to approval from Dell Financial Services²

Receive 4496 points
in rewards
Receive 6752 points
in rewards
Receive 6159 points
in rewards
ResponsiveMessagingKey_Not_Found(shop_fast_delivery_description)
Smart Selection
 
Ships in 3–4 business days
Ships in 3–4 business days
Ships in 3–4 business days
Ships in 3–4 business days
Ships in 3–4 business days
Order Code scv3020sas
Order Code scv3020iscsi
Order Code scv3020fc
Order Code scv3000sas

Add-on item

Coming soon

Ships in 3–4 business days

No longer available

Available to purchase in stores only

Find Retailer

Available to purchase in stores only

Limited Stock

Temporarily out of stock

Notify Me

Ships in 3–4 business days

Pre-Order

Pre-order today

Available

Chassis Overview :
  • Chassis format
    All-in-one (dual controllers, internal drive bays, networking and expansion ports)

    Rack size
    3U

    Controllers
    2 hot-swappable per chassis (active/active)

    Processors
    Intel® Xeon® Processor E5-2603v4, 1.7GHz, 6 cores

    Internal storage capacity
    SCv3000:
    16 x 3.5” drive bays
    SCv3020: 30 x 2.5” drive bays

    System memory
    32GB per SCv3xxx array (16GB per controller)

    Operating system
    Storage Center OS (SC OS) 7.2 or greater
Expansion Capacity :
  • Supported expansion enclosures
    SCv300: 12 x 3.5” drive bays (12Gb SAS)
    SCv320: 24 x 2.5” drive bays (12Gb SAS)
    SCv360: 60 x 3.5” drive bays (12Gb SAS)i

    Maximum drive count
    222 per array (internal plus external expansion), more in federated systemsi

    Max raw capacity
    1PB per arrayi (SSD or HDD), more in federated systems

    Storage media
    SAS and NL-SAS drives; different drive types, transfer rates and rotational speeds can be mixed in the same system.
    SSD: write-intensive and read-intensive drives
    HDD: 15K, 10K, 7.2K RPM
Network and Expansion I/O :
  • Front-end-network protocols
    FC, iSCSI, SAS (supports simultaneous multiprotocol): FC + iSCSI or SAS + iSCSI)

    Max 16Gb FC ports
    8 per array (SFP+)

    Max 10Gb iSCSI ports
    16 SFP+ or BaseT per array

    Max 12Gb SAS ports
    Up to 8 12Gb SAS portsi

    Management ports
    2 per array (1Gb BASE-T)

    Back-end expansion protocols
    12Gb SAS

    Max back-end expansion ports
    8 per array
    Up to 16 expansion enclosures per array
Functional :
  • Array configurations
    All-flash, hybrid or HDD arrays

    Storage format
    Block (SAN)i

    Max SAN hosts: 250
    Max initiator ports: 500
    Max LUN size 500TB
    Max number of LUNs: 1000
    Max number of snapshots: 4096
    Max IOPS: 665,000i 
    Max IOPS (with latency less than 1ms): 540,000i 
    Max IOPS (80% reads, 20% writes): 231,000i 
    Max throughput (reads): 19,000 MB/si 
    Max throughput (writes): 9,500 MB/si
Data Optimization :
  • Auto-tiering method
    Policy-based migration based on real-time data usage, customizable 512KB-4MB page size.

    Auto-tiering structure
    Up to 3 primary (media-based) tiers total, up to 2 SSD tiers (write- and read-intensive SSDs)

    Tiering customizations
    User-defined profiles, option to “pin” volumes to any tier

    RAID support
    RAID 0, 1, 5, 6, RAID 10, and RAID 10 DM (Dual Mirror); any combination of RAID levels can exist on a single array

    RAID tiering
    Auto-provisions and dynamically restripes multiple RAID levels on the same tier; no need to pre-allocate RAID groups

    Thin provisioning
    Active by default on all volumes, operates at full performance across all features

    Thin snapshots
    Records changes only, snapshots auto-migrate to lower-cost storage

    Intelligent compression
    Selectable option per volume
    Applies to SSDs, HDDs or both in hybrid configurations

    HDD optimization
    FastTrack moves frequently accessed data to outer tracks for quicker response times
Data Mobility and Migration :
  • Replication
    Replicates with other SC Series arraysi
    Synchronous/Asynchronous via FC or iSCSI
    Target/source relationships may be one-to-many or many-to-one
    Supports all SC data services on source and target volumes
    Change replication types and topologies on demand
    Supports cross-platform replication with PS Series/EqualLogic arrays (either direction)

    Volume mobility
    Live Migrate (included in base product) enables host-transparent data movement among arrays; see also Federation section

    Federated multi-array systems
    Live Migrate (included in base product) enables host-transparent movement of volumes among arrays
    Snapshots maintained/preserved during migration

    Thin Import
    Space-efficient, non-disruptive data migration from PS Series (EqualLogic) arrays

    Thin Clones
    Clone standalone volumes with zero duplication of data
    Clones maintain independent snapshots and replication
    Ideal for VDI, test/dev, other applications that require discrete instances of common data
    More efficient than dedupe for database copies
Physical :
  • SCv3000
    Rack size: 3U
    Height: 13.33 cm (5.25 inches)
    Width: 44.5 cm (17.52 inches)
    Depth: 78.5 cm (30.9 inches)
    Weight at maximum configuration: 24.22 kg (53.4 lb)
    Weight empty: 15.15 kg (33.4 lb)

    SCv3020
    Rack size: 3U
    Height: 13.33 cm (5.25 inches)
    Width: 44.5 cm (17.52 inches)
    Depth: 78.5 cm (30.9 inches)
    Weight at maximum configuration: 24.22 kg (53.4 lb)
    Weight empty: 15.15 kg (33.4 lb)
Management :
  • Management interface
    Browser-based (HTML 5):
    Unisphere for SC (element manager)
    Unisphere Central (multi-array management)
    CloudIQ (cloud-based analytics and monitoring)

    Client application:
    Dell Storage Manager (multi-array, multi-site, cross-platform management)

    Federation
    Create large multi-array systems under unified management, with seamless workload migration between arrays via included Live Migrate feature. Add arrays non-disruptively, efficiently utilizing their combined capacity and performance. Volume Advisor monitors federated arrays to suggest optimal data placement and load balancing. Volume movement does not impact snapshots or replication data protection.i

    Scripting support
    Microsoft PowerShell API
    RESTful API

    Host OS support
    Microsoft® Windows Server®, Novell® NetWare, SLES, VMware®, Citrix® XenServer®, RedHat®

    Third-party application integration
    VMware, Microsoft, IBM, OpenStack, Oracle, Symantec, Commvault, Foglight, Docker

    Coexistence with PS Series arrays
    Replication in either direction
    Day-to-day management from a single interface
    Thin import: space-efficient, non-disruptive data migration from PS Series arrays

    Certifications
    VMware vSphere Metro Storage Cluster, VMware SRM, Veritas Storage Foundations Suite; see Dell Storage Support Matrix for additional certifications and details

    Reporting/alerts
    Support assist (phone home), remote diagnostics and performance monitoring, automated alerts, reports and notifications, departmental chargeback

    Firmware updates
    Online, non-disruptive.iFirmware may be set to download automatically, with option to trigger installation manually if desired.

    Workload management
    QoS, VVOLs
Power :
  • Power/wattage: 2 hot-swappable power supplies (1378W or 1485W options available, wattage type not interchangeable after point of sale)
    Maximum output power: 1378W supply option: 1378 W; 1485W supply option: 1485 W
    Maximum input power: 1378W supply option: 1584 W; 1485W supply option: 1688 W
    Maximum input current: 1378W supply option: 16 A, 1485W supply option: 8.8 A
    Maximum inrush current: 55A for 10 ms or less
    Nominal input voltage operating range: 1378W supply option: 100-240 VAC; 1485W supply option: 200-240 VAC
    Nominal input frequency: 50/60 Hz
    Maximum thermal output/heat dissipation: 1378W option: 5,770 BTU per hour; 1485 option: 5,760 BTU per hour (for all-in-one base appliance, no expansion enclosures)
Environmental Operating Conditions :
  • Operating temperature: 50 - 95°F (10 - 35°C)
    Non-operating temperature: -40 - 149°F (-40 - 65°C)
    Operating humidity ranges (non-condensing): 10% to 80% with 29°C (84.2°F) maximum dew point
    Non-operating humidity (non-condensing): 5% to 95% with 33°C (91°F) maximum dew point
    Inlet type: NEMA 5-15/CS22.2, n°42
Chassis Overview :
  • Chassis format
    All-in-one (dual controllers, internal drive bays, networking and expansion ports)

    Rack size
    3U

    Controllers
    2 hot-swappable per chassis (active/active)

    Processors
    Intel® Xeon® Processor E5-2603v4, 1.7GHz, 6 cores

    Internal storage capacity
    SCv3000:
    16 x 3.5” drive bays
    SCv3020: 30 x 2.5” drive bays

    System memory
    32GB per SCv3xxx array (16GB per controller)

    Operating system
    Storage Center OS (SC OS) 7.2 or greater
Expansion Capacity :
  • Supported expansion enclosures
    SCv300: 12 x 3.5” drive bays (12Gb SAS)
    SCv320: 24 x 2.5” drive bays (12Gb SAS)
    SCv360: 60 x 3.5” drive bays (12Gb SAS)i

    Maximum drive count
    222 per array (internal plus external expansion), more in federated systemsi

    Max raw capacity
    1PB per arrayi (SSD or HDD), more in federated systems

    Storage media
    SAS and NL-SAS drives; different drive types, transfer rates and rotational speeds can be mixed in the same system.
    SSD: write-intensive and read-intensive drives
    HDD: 15K, 10K, 7.2K RPM
Network and Expansion I/O :
  • Front-end-network protocols
    FC, iSCSI, SAS (supports simultaneous multiprotocol): FC + iSCSI or SAS + iSCSI)

    Max 16Gb FC ports
    8 per array (SFP+)

    Max 10Gb iSCSI ports
    16 SFP+ or BaseT per array

    Max 12Gb SAS ports
    Up to 8 12Gb SAS portsi

    Management ports
    2 per array (1Gb BASE-T)

    Back-end expansion protocols
    12Gb SAS

    Max back-end expansion ports
    8 per array
    Up to 16 expansion enclosures per array
Functional :
  • Array configurations
    All-flash, hybrid or HDD arrays

    Storage format
    Block (SAN)i

    Max SAN hosts: 250
    Max initiator ports: 500
    Max LUN size 500TB
    Max number of LUNs: 1000
    Max number of snapshots: 4096
    Max IOPS: 665,000i 
    Max IOPS (with latency less than 1ms): 540,000i 
    Max IOPS (80% reads, 20% writes): 231,000i 
    Max throughput (reads): 19,000 MB/si 
    Max throughput (writes): 9,500 MB/si
Data Optimization :
  • Auto-tiering method
    Policy-based migration based on real-time data usage, customizable 512KB-4MB page size.

    Auto-tiering structure
    Up to 3 primary (media-based) tiers total, up to 2 SSD tiers (write- and read-intensive SSDs)

    Tiering customizations
    User-defined profiles, option to “pin” volumes to any tier

    RAID support
    RAID 0, 1, 5, 6, RAID 10, and RAID 10 DM (Dual Mirror); any combination of RAID levels can exist on a single array

    RAID tiering
    Auto-provisions and dynamically restripes multiple RAID levels on the same tier; no need to pre-allocate RAID groups

    Thin provisioning
    Active by default on all volumes, operates at full performance across all features

    Thin snapshots
    Records changes only, snapshots auto-migrate to lower-cost storage

    Intelligent compression
    Selectable option per volume
    Applies to SSDs, HDDs or both in hybrid configurations

    HDD optimization
    FastTrack moves frequently accessed data to outer tracks for quicker response times
Data Mobility and Migration :
  • Replication
    Replicates with other SC Series arraysi
    Synchronous/Asynchronous via FC or iSCSI
    Target/source relationships may be one-to-many or many-to-one
    Supports all SC data services on source and target volumes
    Change replication types and topologies on demand
    Supports cross-platform replication with PS Series/EqualLogic arrays (either direction)

    Volume mobility
    Live Migrate (included in base product) enables host-transparent data movement among arrays; see also Federation section

    Federated multi-array systems
    Live Migrate (included in base product) enables host-transparent movement of volumes among arrays
    Snapshots maintained/preserved during migration

    Thin Import
    Space-efficient, non-disruptive data migration from PS Series (EqualLogic) arrays

    Thin Clones
    Clone standalone volumes with zero duplication of data
    Clones maintain independent snapshots and replication
    Ideal for VDI, test/dev, other applications that require discrete instances of common data
    More efficient than dedupe for database copies
Physical :
  • SCv3000
    Rack size: 3U
    Height: 13.33 cm (5.25 inches)
    Width: 44.5 cm (17.52 inches)
    Depth: 78.5 cm (30.9 inches)
    Weight at maximum configuration: 24.22 kg (53.4 lb)
    Weight empty: 15.15 kg (33.4 lb)

    SCv3020
    Rack size: 3U
    Height: 13.33 cm (5.25 inches)
    Width: 44.5 cm (17.52 inches)
    Depth: 78.5 cm (30.9 inches)
    Weight at maximum configuration: 24.22 kg (53.4 lb)
    Weight empty: 15.15 kg (33.4 lb)
Management :
  • Management interface
    Browser-based (HTML 5):
    Unisphere for SC (element manager)
    Unisphere Central (multi-array management)
    CloudIQ (cloud-based analytics and monitoring)

    Client application:
    Dell Storage Manager (multi-array, multi-site, cross-platform management)

    Federation
    Create large multi-array systems under unified management, with seamless workload migration between arrays via included Live Migrate feature. Add arrays non-disruptively, efficiently utilizing their combined capacity and performance. Volume Advisor monitors federated arrays to suggest optimal data placement and load balancing. Volume movement does not impact snapshots or replication data protection.i

    Scripting support
    Microsoft PowerShell API
    RESTful API

    Host OS support
    Microsoft® Windows Server®, Novell® NetWare, SLES, VMware®, Citrix® XenServer®, RedHat®

    Third-party application integration
    VMware, Microsoft, IBM, OpenStack, Oracle, Symantec, Commvault, Foglight, Docker

    Coexistence with PS Series arrays
    Replication in either direction
    Day-to-day management from a single interface
    Thin import: space-efficient, non-disruptive data migration from PS Series arrays

    Certifications
    VMware vSphere Metro Storage Cluster, VMware SRM, Veritas Storage Foundations Suite; see Dell Storage Support Matrix for additional certifications and details

    Reporting/alerts
    Support assist (phone home), remote diagnostics and performance monitoring, automated alerts, reports and notifications, departmental chargeback

    Firmware updates
    Online, non-disruptive.iFirmware may be set to download automatically, with option to trigger installation manually if desired.

    Workload management
    QoS, VVOLs
Power :
  • Power/wattage: 2 hot-swappable power supplies (1378W or 1485W options available, wattage type not interchangeable after point of sale)
    Maximum output power: 1378W supply option: 1378 W; 1485W supply option: 1485 W
    Maximum input power: 1378W supply option: 1584 W; 1485W supply option: 1688 W
    Maximum input current: 1378W supply option: 16 A, 1485W supply option: 8.8 A
    Maximum inrush current: 55A for 10 ms or less
    Nominal input voltage operating range: 1378W supply option: 100-240 VAC; 1485W supply option: 200-240 VAC
    Nominal input frequency: 50/60 Hz
    Maximum thermal output/heat dissipation: 1378W option: 5,770 BTU per hour; 1485 option: 5,760 BTU per hour (for all-in-one base appliance, no expansion enclosures)
Environmental Operating Conditions :
  • Operating temperature: 50 - 95°F (10 - 35°C)
    Non-operating temperature: -40 - 149°F (-40 - 65°C)
    Operating humidity ranges (non-condensing): 10% to 80% with 29°C (84.2°F) maximum dew point
    Non-operating humidity (non-condensing): 5% to 95% with 33°C (91°F) maximum dew point
    Inlet type: NEMA 5-15/CS22.2, n°42
Chassis Overview :
  • Chassis format
    All-in-one (dual controllers, internal drive bays, networking and expansion ports)

    Rack size
    3U

    Controllers
    2 hot-swappable per chassis (active/active)

    Processors
    Intel® Xeon® Processor E5-2603v4, 1.7GHz, 6 cores

    Internal storage capacity
    SCv3000:
    16 x 3.5” drive bays
    SCv3020: 30 x 2.5” drive bays

    System memory
    32GB per SCv3xxx array (16GB per controller)

    Operating system
    Storage Center OS (SC OS) 7.2 or greater
Expansion Capacity :
  • Supported expansion enclosures
    SCv300: 12 x 3.5” drive bays (12Gb SAS)
    SCv320: 24 x 2.5” drive bays (12Gb SAS)
    SCv360: 60 x 3.5” drive bays (12Gb SAS)i

    Maximum drive count
    222 per array (internal plus external expansion), more in federated systemsi

    Max raw capacity
    1PB per arrayi (SSD or HDD), more in federated systems

    Storage media
    SAS and NL-SAS drives; different drive types, transfer rates and rotational speeds can be mixed in the same system.
    SSD: write-intensive and read-intensive drives
    HDD: 15K, 10K, 7.2K RPM
Network and Expansion I/O :
  • Front-end-network protocols
    FC, iSCSI, SAS (supports simultaneous multiprotocol): FC + iSCSI or SAS + iSCSI)

    Max 16Gb FC ports
    8 per array (SFP+)

    Max 10Gb iSCSI ports
    16 SFP+ or BaseT per array

    Max 12Gb SAS ports
    Up to 8 12Gb SAS portsi

    Management ports
    2 per array (1Gb BASE-T)

    Back-end expansion protocols
    12Gb SAS

    Max back-end expansion ports
    8 per array
    Up to 16 expansion enclosures per array
Functional :
  • Array configurations
    All-flash, hybrid or HDD arrays

    Storage format
    Block (SAN)i

    Max SAN hosts: 250
    Max initiator ports: 500
    Max LUN size 500TB
    Max number of LUNs: 1000
    Max number of snapshots: 4096
    Max IOPS: 665,000i 
    Max IOPS (with latency less than 1ms): 540,000i 
    Max IOPS (80% reads, 20% writes): 231,000i 
    Max throughput (reads): 19,000 MB/si 
    Max throughput (writes): 9,500 MB/si
Data Optimization :
  • Auto-tiering method
    Policy-based migration based on real-time data usage, customizable 512KB-4MB page size.

    Auto-tiering structure
    Up to 3 primary (media-based) tiers total, up to 2 SSD tiers (write- and read-intensive SSDs)

    Tiering customizations
    User-defined profiles, option to “pin” volumes to any tier

    RAID support
    RAID 0, 1, 5, 6, RAID 10, and RAID 10 DM (Dual Mirror); any combination of RAID levels can exist on a single array

    RAID tiering
    Auto-provisions and dynamically restripes multiple RAID levels on the same tier; no need to pre-allocate RAID groups

    Thin provisioning
    Active by default on all volumes, operates at full performance across all features

    Thin snapshots
    Records changes only, snapshots auto-migrate to lower-cost storage

    Intelligent compression
    Selectable option per volume
    Applies to SSDs, HDDs or both in hybrid configurations

    HDD optimization
    FastTrack moves frequently accessed data to outer tracks for quicker response times
Data Mobility and Migration :
  • Replication
    Replicates with other SC Series arraysi
    Synchronous/Asynchronous via FC or iSCSI
    Target/source relationships may be one-to-many or many-to-one
    Supports all SC data services on source and target volumes
    Change replication types and topologies on demand
    Supports cross-platform replication with PS Series/EqualLogic arrays (either direction)

    Volume mobility
    Live Migrate (included in base product) enables host-transparent data movement among arrays; see also Federation section

    Federated multi-array systems
    Live Migrate (included in base product) enables host-transparent movement of volumes among arrays
    Snapshots maintained/preserved during migration

    Thin Import
    Space-efficient, non-disruptive data migration from PS Series (EqualLogic) arrays

    Thin Clones
    Clone standalone volumes with zero duplication of data
    Clones maintain independent snapshots and replication
    Ideal for VDI, test/dev, other applications that require discrete instances of common data
    More efficient than dedupe for database copies
Physical :
  • SCv3000
    Rack size: 3U
    Height: 13.33 cm (5.25 inches)
    Width: 44.5 cm (17.52 inches)
    Depth: 78.5 cm (30.9 inches)
    Weight at maximum configuration: 24.22 kg (53.4 lb)
    Weight empty: 15.15 kg (33.4 lb)

    SCv3020
    Rack size: 3U
    Height: 13.33 cm (5.25 inches)
    Width: 44.5 cm (17.52 inches)
    Depth: 78.5 cm (30.9 inches)
    Weight at maximum configuration: 24.22 kg (53.4 lb)
    Weight empty: 15.15 kg (33.4 lb)
Management :
  • Management interface
    Browser-based (HTML 5):
    Unisphere for SC (element manager)
    Unisphere Central (multi-array management)
    CloudIQ (cloud-based analytics and monitoring)

    Client application:
    Dell Storage Manager (multi-array, multi-site, cross-platform management)

    Federation
    Create large multi-array systems under unified management, with seamless workload migration between arrays via included Live Migrate feature. Add arrays non-disruptively, efficiently utilizing their combined capacity and performance. Volume Advisor monitors federated arrays to suggest optimal data placement and load balancing. Volume movement does not impact snapshots or replication data protection.i

    Scripting support
    Microsoft PowerShell API
    RESTful API

    Host OS support
    Microsoft® Windows Server®, Novell® NetWare, SLES, VMware®, Citrix® XenServer®, RedHat®

    Third-party application integration
    VMware, Microsoft, IBM, OpenStack, Oracle, Symantec, Commvault, Foglight, Docker

    Coexistence with PS Series arrays
    Replication in either direction
    Day-to-day management from a single interface
    Thin import: space-efficient, non-disruptive data migration from PS Series arrays

    Certifications
    VMware vSphere Metro Storage Cluster, VMware SRM, Veritas Storage Foundations Suite; see Dell Storage Support Matrix for additional certifications and details

    Reporting/alerts
    Support assist (phone home), remote diagnostics and performance monitoring, automated alerts, reports and notifications, departmental chargeback

    Firmware updates
    Online, non-disruptive.iFirmware may be set to download automatically, with option to trigger installation manually if desired.

    Workload management
    QoS, VVOLs
Power :
  • Power/wattage: 2 hot-swappable power supplies (1378W or 1485W options available, wattage type not interchangeable after point of sale)
    Maximum output power: 1378W supply option: 1378 W; 1485W supply option: 1485 W
    Maximum input power: 1378W supply option: 1584 W; 1485W supply option: 1688 W
    Maximum input current: 1378W supply option: 16 A, 1485W supply option: 8.8 A
    Maximum inrush current: 55A for 10 ms or less
    Nominal input voltage operating range: 1378W supply option: 100-240 VAC; 1485W supply option: 200-240 VAC
    Nominal input frequency: 50/60 Hz
    Maximum thermal output/heat dissipation: 1378W option: 5,770 BTU per hour; 1485 option: 5,760 BTU per hour (for all-in-one base appliance, no expansion enclosures)
Environmental Operating Conditions :
  • Operating temperature: 50 - 95°F (10 - 35°C)
    Non-operating temperature: -40 - 149°F (-40 - 65°C)
    Operating humidity ranges (non-condensing): 10% to 80% with 29°C (84.2°F) maximum dew point
    Non-operating humidity (non-condensing): 5% to 95% with 33°C (91°F) maximum dew point
    Inlet type: NEMA 5-15/CS22.2, n°42
Chassis Overview :
  • Chassis format
    All-in-one (dual controllers, internal drive bays, networking and expansion ports)

    Rack size
    3U

    Controllers
    2 hot-swappable per chassis (active/active)

    Processors
    Intel® Xeon® Processor E5-2603v4, 1.7GHz, 6 cores

    Internal storage capacity
    SCv3000:
    16 x 3.5” drive bays
    SCv3020: 30 x 2.5” drive bays

    System memory
    32GB per SCv3xxx array (16GB per controller)

    Operating system
    Storage Center OS (SC OS) 7.2 or greater
Expansion Capacity :
  • Supported expansion enclosures
    SCv300: 12 x 3.5” drive bays (12Gb SAS)
    SCv320: 24 x 2.5” drive bays (12Gb SAS)
    SCv360: 60 x 3.5” drive bays (12Gb SAS)i

    Maximum drive count
    222 per array (internal plus external expansion), more in federated systemsi

    Max raw capacity
    1PB per arrayi (SSD or HDD), more in federated systems

    Storage media
    SAS and NL-SAS drives; different drive types, transfer rates and rotational speeds can be mixed in the same system.
    SSD: write-intensive and read-intensive drives
    HDD: 15K, 10K, 7.2K RPM
Network and Expansion I/O :
  • Front-end-network protocols
    FC, iSCSI, SAS (supports simultaneous multiprotocol): FC + iSCSI or SAS + iSCSI)

    Max 16Gb FC ports
    8 per array (SFP+)

    Max 10Gb iSCSI ports
    16 SFP+ or BaseT per array

    Max 12Gb SAS ports
    Up to 8 12Gb SAS portsi

    Management ports
    2 per array (1Gb BASE-T)

    Back-end expansion protocols
    12Gb SAS

    Max back-end expansion ports
    8 per array
    Up to 16 expansion enclosures per array
Functional :
  • Array configurations
    All-flash, hybrid or HDD arrays

    Storage format
    Block (SAN)i

    Max SAN hosts: 250
    Max initiator ports: 500
    Max LUN size 500TB
    Max number of LUNs: 1000
    Max number of snapshots: 4096
    Max IOPS: 665,000i 
    Max IOPS (with latency less than 1ms): 540,000i 
    Max IOPS (80% reads, 20% writes): 231,000i 
    Max throughput (reads): 19,000 MB/si 
    Max throughput (writes): 9,500 MB/si
Data Optimization :
  • Auto-tiering method
    Policy-based migration based on real-time data usage, customizable 512KB-4MB page size.

    Auto-tiering structure
    Up to 3 primary (media-based) tiers total, up to 2 SSD tiers (write- and read-intensive SSDs)

    Tiering customizations
    User-defined profiles, option to “pin” volumes to any tier

    RAID support
    RAID 0, 1, 5, 6, RAID 10, and RAID 10 DM (Dual Mirror); any combination of RAID levels can exist on a single array

    RAID tiering
    Auto-provisions and dynamically restripes multiple RAID levels on the same tier; no need to pre-allocate RAID groups

    Thin provisioning
    Active by default on all volumes, operates at full performance across all features

    Thin snapshots
    Records changes only, snapshots auto-migrate to lower-cost storage

    Intelligent compression
    Selectable option per volume
    Applies to SSDs, HDDs or both in hybrid configurations

    HDD optimization
    FastTrack moves frequently accessed data to outer tracks for quicker response times
Data Mobility and Migration :
  • Replication
    Replicates with other SC Series arraysi
    Synchronous/Asynchronous via FC or iSCSI
    Per-volume QoS bandwidth prioritization
    Target/source relationships may be one-to-many or many-to-one
    Supports all SC data services on source and target volumes
    Change replication types and topologies on demand
    Supports cross-platform replication with PS Series/EqualLogic arrays (either direction)

    Volume mobility
    Live Migrate (included in base product) enables host-transparent data movement among arrays; see also Federation section

    Federated multi-array systems
    Live Migrate (included in base product) enables host-transparent movement of volumes among arrays
    Snapshots maintained/preserved during migration

    Thin Import
    Space-efficient, non-disruptive data migration from PS Series (EqualLogic) arrays

    Thin Clones
    Clone standalone volumes with zero duplication of data
    Clones maintain independent snapshots and replication
    Ideal for VDI, test/dev, other applications that require discrete instances of common data
    More efficient than dedupe for database copies
Physical :
  • SCv3000
    Rack size: 3U
    Height: 13.33 cm (5.25 inches)
    Width: 44.5 cm (17.52 inches)
    Depth: 78.5 cm (30.9 inches)
    Weight at maximum configuration: 24.22 kg (53.4 lb)
    Weight empty: 15.15 kg (33.4 lb)

    SCv3020
    Rack size: 3U
    Height: 13.33 cm (5.25 inches)
    Width: 44.5 cm (17.52 inches)
    Depth: 78.5 cm (30.9 inches)
    Weight at maximum configuration: 24.22 kg (53.4 lb)
    Weight empty: 15.15 kg (33.4 lb)
Management :
  • Management interface
    Browser-based (HTML 5):
    Unisphere for SC (element manager)
    Unisphere Central (multi-array management)
    CloudIQ (cloud-based analytics and monitoring)

    Client application:
    Dell Storage Manager (multi-array, multi-site, cross-platform management)

    Federation
    Create large multi-array systems under unified management, with seamless workload migration between arrays via included Live Migrate feature. Add arrays non-disruptively, efficiently utilizing their combined capacity and performance. Volume Advisor monitors federated arrays to suggest optimal data placement and load balancing. Volume movement does not impact snapshots or replication data protection.i

    Scripting support
    Microsoft PowerShell API
    RESTful API

    Host OS support
    Microsoft® Windows Server®, Novell® NetWare, SLES, VMware®, Citrix® XenServer®, RedHat®

    Third-party application integration
    VMware, Oracle, Microsoft, IBM, OpenStack™, Symantec™, Commvault®, Veeam®, Docker™ -- see SC Series Management spec sheet for more details 

    Coexistence with PS Series arrays
    Replication in either direction
    Day-to-day management from a single interface
    Thin import: space-efficient, non-disruptive data migration from PS Series arrays

    Certifications
    VMware vSphere Metro Storage Cluster, VMware SRM, Veritas Storage Foundations Suite; see Dell Storage Support Matrix for additional certifications and details

    Reporting/alerts
    Support assist (phone home), remote diagnostics and performance monitoring, automated alerts, reports and notifications, departmental chargeback

    Firmware updates
    Online, non-disruptive.iFirmware may be set to download automatically, with option to trigger installation manually if desired.

    Workload management
    QoS, VVOLs
Power :
  • Power/wattage: 2 hot-swappable power supplies (1378W or 1485W options available, wattage type not interchangeable after point of sale)
    Maximum output power: 1378W supply option: 1378 W; 1485W supply option: 1485 W
    Maximum input power: 1378W supply option: 1584 W; 1485W supply option: 1688 W
    Maximum input current: 1378W supply option: 16 A, 1485W supply option: 8.8 A
    Maximum inrush current: 55A for 10 ms or less
    Nominal input voltage operating range: 1378W supply option: 100-240 VAC; 1485W supply option: 200-240 VAC
    Nominal input frequency: 50/60 Hz
    Maximum thermal output/heat dissipation: 1378W option: 5,770 BTU per hour; 1485 option: 5,760 BTU per hour (for all-in-one base appliance, no expansion enclosures)
Environmental Operating Conditions :
  • Operating temperature: 50 - 95°F (10 - 35°C)
    Non-operating temperature: -40 - 149°F (-40 - 65°C)
    Operating humidity ranges (non-condensing): 10% to 80% with 29°C (84.2°F) maximum dew point
    Non-operating humidity (non-condensing): 5% to 95% with 33°C (91°F) maximum dew point
    Inlet type: NEMA 5-15/CS22.2, n°42
More Info More Info More Info More Info

Add-on item

Coming soon

Ships in 3–4 business days

No longer available

Available to purchase in stores only

Find Retailer

Available to purchase in stores only

Limited Stock

Temporarily out of stock

Notify Me

Ships in 3–4 business days

Pre-Order

Pre-order today

Available

Compare Products (0)
Hide

Add the products you would like to compare, and quickly determine which is best for your needs.

Compare
0