Eaton Metered Input rack PDUs give you remote monitoring capabilities and provide access to your power data whenever you want it, wherever you are. You also can monitor your critical equipment within each color-coded outlet section from a single interface, achieve 1% billing grade accuracy and daisy chain eight PDUs to share the same network connection and IP address.
Avoid costly downtime
Remove hot-swappable communications module without disrupting power to the IT equipment.
Media
Easily organize demand
Color-coded outlet sections match circuit breakers for easy identification, preventing unbalanced demand loading.
Reduce network costs
Connect up to eight PDUs using the same IP address, reducing network infrastructure costs by up to 87.5%.
Flexible mounting options
0U, 1U, 2U footprint offerings
Tool-less mounting buttons
Optional side mounting
Clip feet
Save time
Mass configuration management allows you to apply commands across multiple units instantly.
A “U” or “RU” refers to the unit of measurement for racks, PDUs, and UPS products. Rack unit size is defined by the Electronic Industries Alliance (EIA). 1U is equal to 1.75” or 44.45mm. Many rack power distribution units come in 0U (vertical mounting), 1U or 2U (horizontal mounting).
Yes, the Eaton Rack PDU products have universal mounting hardware that will allow it to mount into our competitor’s products. Our tool-less mounting buttons allow the PDUs to seamlessly mount no matter the enclosure.
Yes. Our Metered Input PDUshave a network module that will allow remote management via web or SNMP protocol. Using this in conjunction with our Intelligent Power Management Platform will allow you to have total control of the equipment in your network.
Daisy chaining is a method of linking PDUs that allows for up to 8 rack PDUs to use the same IP address. This reduces network infrastructure costs and allows you to control several groups of power supplies with a single action. This is available on our Metered Input PDU.
Yes. We have detailed instructions along with images in our user manual that tell you how to replace the network module. The module is hot-swappable, which means your outlets will not be affected or change state during the process.
Eaton G3 Metered Input ePDUs provide a best-in-class design featuring billing grade accuracy monitoring of input and branch circuits on a local LCD pixel display or over a network connection. The high accuracy meter will measure current, voltage, power and energy for load balancing, capacity planning, efficiency monitoring and energy usage reporting. Designed for IT and data center applications means high reliability and a robust design made for high operating temperatures found in containment or networking closets.
Tech Specs
General
Device Type
Power distribution unit - rack-mountable
Height (Rack Units)
38U
Color
Black
Power Device
Input Voltage
AC 120 V
Input Voltage Range
AC 100 - 127 V
Frequency Required
50 - 60 Hz
Input Connectors
1 x power NEMA 5-15
Power Output Connectors Details
24 x power NEMA 5-15
Output Voltage
AC 100-127 V
Max Electric Current
12 A
Power Capacity
1.44 kW
Networking
Remote Management Interface
Ethernet 10/100, RS-232
Expansion / Connectivity
Interfaces
1 x management (Ethernet) - RJ-45
1 x management (RS-232) - RJ-45
1 x cascading - RJ-45
Miscellaneous
Cables Included
Power cable - integrated - 10 ft
Features
LCD display, voltage monitoring, vertical orientation
Compliant Standards
UL 60950-1, cULus, UL 489
Environmental Parameters
Min Operating Temperature
32 °F
Max Operating Temperature
140 °F
Dimensions & Weight
Width
2.1 in
Depth
2.1 in
Height
66.5 in
Dimensions & Weight (Shipping)
Shipping Width
7.7 in
Shipping Depth
9.3 in
Shipping Height
77.6 in
Compare Products ()
Add the products you would like to compare, and quickly determine which is best for your needs.
Add the products you would like to compare, and quickly determine which is best for your needs.