Passer au contenu principal
  • Passer des commandes rapidement et facilement
  • Afficher les commandes et suivre l’état de votre expédition
  • Créez et accédez à une liste de vos produits

Precision Rack 7910 Workstation – Error UEFI0067 after post

Cet article concerne   Cet article ne concerne pas 

Symptômes



Customers may report that they are seeing the error UEFI0067 Messaage A PCIe link training failure is observed in arg1 and device link is disabled towards the end of POST in Precision R7910 Rack Mounted Workstation. 

This issue is seen due to loose contact between the network / video cards in the PCI slots primarily because they are seated incorrectly.

Résolution



No Hardware Replacement is required. 

Flashing the BIOS without the PCI cards in the slot will resolve the error. 

Troubleshooting Steps:
  1. Shutdown the System.
  2. Remove all the PCI Cards from the slots. 
  3. Restart the system and Flash the BIOS.
  4. Replace the cards in the respective slots. 

For more information, refer to SLN295913 : Precision R7910 Rack Mounted Workstation : A Visual Guide 

Produits concernés

Precision Rack 7910