VRTX - Performing a racadm racresetcfg may cause SPERC-E to enter into safe mode.

VRTX - Performing a racadm racresetcfg may cause SPERC-E to enter into safe mode.


Performing a racadm racresetcfg may cause SPERC-E to enter into safe mode. This behavior may be seen with a VRTX External JBOD solution consisting of the following components:

  • VRTX - CMC 2.1
  • Dual SPERC-E in Fault Tolerance Mode
  • Single or Dual MD 1200/1220 Arrays

Additionally the following or similar critical error will be observed in the CMC GUI.

CTL96 RAID Controller in Chassis Slot 6 has entered safe mode with limited functionality due to Critical Error during boot - All drives will be hidden


Solution


The CMC resets the default value for SPERC-E to non-FT (Fault Tolerant). Access to data during this condition will not be impacted as a single SPERC-E will take over. However the SPERC-E configuration will no longer be in Fault Tolerant (FT) mode until it is back into FT mode.

Warning: A maintenance window for down time is required.


To correct this behavior, please perform the following steps to recover:


1. Power down all blade servers in the VRTX Chassis.
2. Place the SPERC-E controllers into FT Mode.
Chassis Overview >> Controllers >> Troubleshooting >> Enable Fault Tolerance >> Apply (Perform this for both SPERC-E in PCIe Slot 5 & 6).
3. Reboot VRTX Chassis.

The issue will be fixed in the CMC version 2.2 for PowerEdge VRTX .




Need more help?
Find additional PowerEdge and PowerVault articles

Visit and ask for support in our Communities

Create an online support Request




Quick Tips content is self-published by the Dell Support Professionals who resolve issues daily. In order to achieve a speedy publication, Quick Tips may represent only partial solutions or work-arounds that are still in development or pending further proof of successfully resolving an issue. As such Quick Tips have not been reviewed, validated or approved by Dell and should be used with appropriate caution. Dell shall not be liable for any loss, including but not limited to loss of data, loss of profit or loss of revenue, which customers may incur by following any procedure or advice set out in the Quick Tips.

Identifikátor článku: SLN302716

Dátum poslednej zmeny: 08/25/2016 08:30 AM


Ohodnotiť tento článok

Presné
Užitočné
Jednoducho pochopiteľné
Bol pre vás tento článok užitočný?
Áno Nie
Pošlite nám pripomienky.
Poznámky nemôžu obsahovať nasledujúce špeciálne znaky: <>()\
Ľutujeme, náš systém odosielania pripomienok je momentálne nefunkčný. Skúste znova neskôr.

Ďakujeme vám za pripomienky.