跳至主要內容
  • 簡單快速地下訂單
  • 檢視訂單及追蹤商品運送狀態
  • 建立並存取您的產品清單
  • 使用「公司管理」來管理您的 Dell EMC 網站、產品和產品層級連絡人。

文章編號: 000149997


Improper SCSI Termination Causes POST Error on the Dell™ PowerVault™ 120T DLT1 Autoloader. - KB Article - 150558

本文可能採用自動翻譯。如果您對翻譯品質有任何寶貴意見,請使用此頁面底部的表單告訴我們,謝謝。

文章內容


症狀

Check the plug-in terminator on the back of the autoloader.

There are two SCSI connectors on the back of the unit. One should have the cable attached and the other connector should have a SCSI terminator attached.



The Drive Must Be Terminated.

On a PowerVault 120T DLT1 Autoloader, the drive must be terminated in order for the unit to complete POST. If the drive is not properly terminated, the LCD displays the error message LDR INIT and the alarm sounds with a solid beep.

 

 

The PowerVault 120T Autoloader DLT1 is an LVD SCSI device. SCSI devices require termination on each end of the SCSI bus. The termination for this device is in the form of a plug-in terminator on the PowerVault 120T.



文章屬性


上次發佈日期

20 11月 2020

版本

2

文章類型

Solution